C. Primary Corona Assembly
1. Detaching the Primary Corona Assembly
1) Detach the drum unit.
2) Slide the lock
q
of the top of the drum unit in the direction of the arrow.
Figure 4-319
3) Detach the primary corona assembly unit
w
together with the holder while rotating it
in the direction of the arrow.
Figure 4-320