![background image](http://html.mh-extra.com/html/canon/np6218/np6218_service-manual_62356112.webp)
4) Remove the three screws
r
, and detach the blank exposure lamp
t
.
Figure 4-312
5. Detaching the Blank Shutter Solenoid
1) Detach the blank exposure assembly.
2) Detach the blank shutter upper plate, and disconnect the connector
q
. (See “3.
Detaching the Blank Exposure Assembly on p. 4-34.”)
3) Remove the E-ring
w
, and detach the link arm
e
from the blank shutter.
4) Remove the two screws
r
, and pull out the blank shutter solenoid.
Figure 4-313
COPYRIGHT © 1997 CANON INC. CANON NP6218 REV. 0 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 4 IMAGE FORMATION SYSTEM
4-36
r
t
e
r
q
w