sec.) has occurred.
##779 TX
After transmitting EOR-MPS in ECM
transmission, ERR has been received.
- Try a higher transmission level.
##780 TX
After transmitting EOR-EOM in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Increase the transmission level of the
receiving machine.
##782 TX
After transmitting EOR-EOM in ECM
transmission, DCN has been received.
- Increase the transmission level of the
receiving machine.
##783 TX
After transmitting EOR-EOM in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##784 TX
After transmitting EOR-EOM in ECM
transmission, ERR has been received.
- Try a higher transmission level.
##785 TX
After transmitting EOR-EOP in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
- Increase the transmission level of the
receiving machine.
##787 TX
After transmitting EOR-EOP in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##788 TX
After transmitting EOR-EOP in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##789 TX
After transmitting EOR-EOP in ECM
transmission, ERR has been received.
- Try a higher transmission level.
##790 RX
After receiving EOR-EOP in ECM reception,
ERR has been transmitted.
- Increase the transmission level of the
sending machine.
##791 TX / RX During the ECM mode procedure, a signal other
than a significant one has been received.
##792 RX
In ECM reception, PPS-NULL between partial
pages has not been detected.
- Increase the transmission level of the
sending machine.
##793 RX
During high-speed signal reception in ECM, no
effective frame has been detected, and a time-
over has occurred.
- Try a higher transmission level.
- Increase the transmission level of the
sending machine.
<1. TROUBLESHOOTING>
18 / 76
Summary of Contents for MX883
Page 32: ...8 Remove the main case no screws 28 76 ...
Page 35: ...4 Remove the LCD ass y no screws 31 76 ...
Page 55: ... 2 Service Tool functions Service Tool screen Version 2 000 51 76 ...
Page 56: ...52 76 ...
Page 67: ...63 76 ...
Page 74: ...4 2 Integrated Inspection Pattern Print Print sample ...
Page 75: ...4 3 Ink Absorber Counter Value Print Print sample 4 VERIFICATION AFTER REPAIR ...
Page 78: ......