transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##752 TX
After transmitting PPS-NULL in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##753 TX
After transmitting PPS-NULL in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##754 TX
After transmitting PPS-NULL in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
##755 TX
After transmitting PPS-MPS in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
##757 TX
After transmitting PPS-MPS in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##758 TX
After transmitting PPS-MPS in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##759 TX
After transmitting PPS-MPS in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
##760 TX
After transmitting PPS-EOM in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
- Try a higher transmission level.
##762 TX
After transmitting PPS-EOM in ECM
transmission, DCN has been received.
- Try a higher transmission level.
##763 TX
After transmitting PPS-EOM in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
- Increase the period of time of the T5
time-over.
##764 TX
After transmitting PPS-EOM in ECM
- Try a higher transmission level.
16 / 76
Summary of Contents for MX883
Page 32: ...8 Remove the main case no screws 28 76 ...
Page 35: ...4 Remove the LCD ass y no screws 31 76 ...
Page 55: ... 2 Service Tool functions Service Tool screen Version 2 000 51 76 ...
Page 56: ...52 76 ...
Page 67: ...63 76 ...
Page 74: ...4 2 Integrated Inspection Pattern Print Print sample ...
Page 75: ...4 3 Ink Absorber Counter Value Print Print sample 4 VERIFICATION AFTER REPAIR ...
Page 78: ......