7
7
7-4
7-4
Error Codes > Error Codes
Error Codes > Error Codes
Code
Detection description
Remedy
E225 0001 Light intensity of a lamp is
less or equal to the criteria
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller
Board (J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E301 0001 Insufficient light intensity in
shading
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller
Board (J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E736 0000
Communication error with
CCU/modem, or no FAX
board installed on FAX
model.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of connectors between the
Main Controller Board (J601, J602) and the FAX-
NCU Board (J1201, J1204).
(2) Replace the connectors between the Main Controller
Board (J601, J602) and the FAX-NCU Board (J1201,
J1204).
(3) Replace the FAX-NCU Board.
(4) Replace the Main Controller Board.
E740 0002
Error detection on either
Network Board or Mac
address
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of the network cable.
(2) Replace the Main Controller Board.
E744
0002 Language file error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
Update the set of the Controller Firmware
4000
Engine ID error (Invalid
engine connection is
detected)
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the Engine Controller Board.
(2) Update the Engine Firmware.
(3) Update the set of the Controller Firmware
Code
Detection description
Remedy
E806 0000 Fan Motor cannot rotate at
specified revolution speed.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Replace the Main Fan Unit.
(2) Replace the Engine Controller Board.
T-7-2
Summary of Contents for MF4500 Series
Page 222: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Page 224: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Version Upgrade ...
Page 230: ...7 7 Error Codes Error Codes Overview Error Codes ...
Page 234: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 251: ... Service Tools Solvent Oil List General Circuit Diagram General Timing Chart Appendix ...