Disassembly/Assembly > Controller System > Removing the Main Motor Duplex models (MF4580dn/MF4570dn/MF4550d/MF4553d/MF4554d/D550/D520)
Disassembly/Assembly > Controller System > Removing the Main Motor Duplex models (MF4580dn/MF4570dn/MF4550d/MF4553d/MF4554d/D550/D520)
Caution:
When mounting the main motor, attach the harness [1] to the upper side of the motor .
[1]
F-4-211
Caution:
When mounting the scanner cover, pass the shutter open/close lever [1] through the
hole [A] in the scanner cover.
[1]
[A]
Ensure that the shutter open/close lever [1] can move vertically.
[1]
F-4-212
F-4-213