LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
66
9.11.9 CR_P-MANE Command
Command “CR_P-MANE”[CR]
Details
Get Power management mode setting status
Response
Acceptable “000_%a”[CR]
%a
“OFF” -------------------------- Power management mode is OFF
“READY” ---------------------- Power management mode is Standby
“SHUTDOWN” ---- Power management mode is set to Exit
Unacceptable “Error Code” [CR]
9.11.10 CR_P-MANETIME Command
Command “CR_P-MANETIME”[CR]
Details
Get time to start Power management mode
Response
Acceptable “000_%a”[CR]
%a “001”~”030”
-----------------------1
minute to 30 minutes
Unacceptable “Error Code” [CR]
9.11.11 CR_ON-STA Command
Command “CR_ON-STA”[CR]
Details
Get Direct power on setting status
Response
Acceptable “000_%a”[CR]
%a
“ON” -------------------------- Direct power on is ON
“OFF” ------------------------- Direct power on is OFF
Unacceptable “Error Code” [CR]
9.11.12 CR_STANDBYMODE Command
Command “CR_STANDBYMODE”
[CR]
Details
Get Standby Mode setting status
Response
Acceptable “000_%a”[CR]
%a
“ECO” -------------- Eco Mode
“NORMAL” -------- Normal Mode
Unacceptable “Error Code” [CR]
9.11.13
CR_PTIMEMODE Command
Command “CR_PTIMEMODE”[CR]
Details
Get operation mode of P-timer.
Response
Acceptable “000_%a”[CR]
%a
“COUNTUP” ---------------- Count up is selected
“COUNTDN” ---------------- Count down is selected.
Unacceptable “Error code”[CR]