LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
19
8.4.5 CF_IRIS
Command
Command “CF_IRIS_%1“[CR]
%1
“ON”-------------------Set Auto iris to On
“OFF” ”----------------Set Auto iris to Off
Details
Set Auto iris.
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error
Code”[CR]
8.4.6 CF_SHARP
Command
Command “CF_SHARP_%1”[CR]
%1
“000~015” ---------------- Directly select Sharpness setting value
“UP” ------------------------ Current Sharpness setting value + 1
“DN” ------------------------ Current Sharpness setting value - 1
Details
Set Sharpness value of user control
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error
Code”[CR]
8.4.7 CF_GAMMA
Command
Command “CF_GAMMA_%1”[CR]
%1
“000~015” ---------------- Directly set Gamma setting value
“UP” ------------------------ Current Gamma setting value + 1
“DN” ------------------------ Current Gamma setting value – 1
Details
Set Gamma value of user control
Projector does not save the value set with this command so that it resets when
projector turning into Standby status or ALL is OFF. (The value is held in Suspend
mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error
Code”[CR]