LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
34
8.8 Lamp
Command
8.8.1 CF_LAMPH
Command
Command “CF_LAMPH_%1”[CR]
%1 “RST”
Details
Reset total lamp running time
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error
Code”[CR]
8.8.2 CF_LAMPMODE
Command
Command “CF_LAMPMODE_%1”[CR]
%1
“HIGH” ------------ Set lamp to High mode status
“NORMAL” ------- Set lamp to Normal mode status
“ECO” ------------- Set lamp to Eco mode status
“UP” --------------- The same operation as pressing Up key or Left key
“DN” --------------- The same operation as pressing Down key or Right key
Details
Select Lamp Mode
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable “Error
Code”[CR]