LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications
62
9.9.5 CR_LAMPMSTS
Command
Command “CR_LAMPSTS”[CR]
Details
Get Lighting status of lamp
Response
Acceptable “000_%1”[CR]
%1
“n**** ” A number of * should be among 1-4.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Second character shows following status in order of lamp number.
“I” Lamp is ON
“O” Lamp is OFF
“X” Lamp failure
e.g.
“1I”
・・・・・・・
1 lamp model and Lamp is ON
“2IO
・・・・・・・
2 lamps model and No.1 Lamp is ON and No.2Lamp
is OFF
“4IOXI”
・・・・
4 lamps model and No.1,No.4 lamps are ON. No.2
lamp is OFF and No.3 model is failed.
Unacceptable “Error
Code”[CR]
9.9.6 CR_PROJH
Command
Command “CR_PROJH”[CR]
Details
Get total running time of Projector by hour (h)
Response
Acceptable “000_%1”[CR]
%1 “0000000”~“0099999”
Unacceptable “Error
Code”[CR]
9.9.7 CR_HMLAMP
Command
Command “CR_HMLAMP”[CR]
Details
Get lamp number.
Response
Acceptable “000_%1”[CR]
%1 “001”
Unacceptable “Error Code” [CR]