Chapter 6
6-11
<Cause>
When the suction fan was driven, the lock signal was detected for more than the specified time.
<Probable fault location>
Suction fan or main controller PCB
<Countermeasure>
1) Suction fan
2) Replace the main controller PCB.
6.1.3.33 03030000-2E21 IEEE1394 Error
0013-7192
iPF9000
<Cause>
The IEEE1394 interface is faulty.
<Probable fault location>
IEEE1394 interface board or main controller PCB
<Countermeasure>
1) Turn off the printer, and then turn it on again.
2) IEEE1394 interface board
Remove the IEEE1394 interface board, install it again, and then turn on the printer. If the trouble persists, replace the IEEE1394 interface board.
3) Replace the main controller PCB.
6.1.3.34 03130031-2F25 Carriage home position error
0013-6976
iPF9000
<Cause>
The carriage home position could not be detected within the specified time.
<Probable fault location>
Sensor flag, carriage HP sensor, linear scale, linear encoder, carriage relay PCB, or main controller PCB
<Countermeasure>
1) Visual check
Remove foreign substances from the sensor flag, carriage HP sensor, linear scale, and linear encoder if any.
2) Replace the carriage HP sensor.
3) Replace the linear scale.
4) Replace the linear encoder.
5) Replace the carriage relay PCB.
6) Replace the main controller PCB.
6.1.3.35 03130031-2F26/03130031-2F27 Carriage motor error
0012-6653
iPF9000
<Cause>
The carriage did not operate because the carriage motor was overloaded due to a physical cause such as a jam.
The carriage motor did not reach the specified speed within the specified time.
<Probable fault location>
Carriage pathway, carriage rail, carriage belt, linear scale, linear encoder, carriage motor, carriage relay PCB, or main controller PCB
<Countermeasure>
1) Carriage pathway check
Remove foreign substances (jammed paper) from the carriage pathway if any.
2) Carriage rail
Visually check whether the carriage rail is dirty. If the carriage rail is dirty, clean it.
3) Carriage belt
Visually check whether the carriage belt is loose. If the carriage belt is loose, remove it and then reinstall it.
4) Replace the linear scale.
5) Replace the linear encoder.
6) Replace the carriage motor.
7) Replace the carriage relay PCB.
8) Replace the main controller PCB.
6.1.3.36 03130031-2F1F/03130031-2F20 Defective sensor in purge unit
0012-6646
iPF9000
<Cause>
The each sensors in the purge unit could not detect the home position of the purge motor within the specified time.
<Probable fault location>
Purge unit or main controller PCB
<Countermeasure>
1) Visual check
Remove foreign substance from purge unit if any.
2) Replace the purge unit.
3) Replace the main controller PCB.
Summary of Contents for iPF9000 series
Page 1: ...Aug 8 2007 Service Manual iPF9000 series ...
Page 2: ......
Page 6: ......
Page 13: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 14: ......
Page 25: ...Chapter 1 1 9 F 1 13 ...
Page 102: ...Chapter 1 1 86 ...
Page 103: ...Chapter 1 1 87 ...
Page 104: ......
Page 105: ...Chapter 2 TECHNICAL REFERENCE ...
Page 106: ......
Page 172: ......
Page 173: ...Chapter 3 INSTALLATION ...
Page 174: ......
Page 176: ......
Page 218: ...Chapter 3 3 42 F 3 85 6 FAN UNIT 7 FAN UNIT A ...
Page 231: ...Chapter 3 3 55 F 3 107 6 FAN UNIT 7 FAN UNIT A ...
Page 233: ...Chapter 3 3 57 ...
Page 234: ......
Page 235: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Page 236: ......
Page 238: ......
Page 273: ...Chapter 4 4 35 ...
Page 274: ......
Page 275: ...Chapter 5 MAINTENANCE ...
Page 276: ......
Page 278: ......
Page 285: ...Chapter 5 5 7 ...
Page 286: ......
Page 287: ...Chapter 6 TROUBLESHOOTING ...
Page 288: ......
Page 354: ......
Page 355: ...Chapter 7 SERVICE MODE ...
Page 356: ......
Page 358: ......
Page 420: ......
Page 421: ...Chapter 8 ERROR CODE ...
Page 422: ......
Page 424: ......
Page 431: ...Aug 8 2007 ...
Page 432: ......