Chapter 6
6-2
<Countermeasure>
1) Check the ink tank to see if it is set properly.
2) Replace the ink tank.
3) Replace the ink tank unit.
4) Replace the main controller PCB.
6.1.2.5 Close Ink Tank Cover
0014-9149
iPF9000
<Cause>
The ink tank cover has been opened during printing,
<Probable fault location>
Operation method, ink tank cover switch, ink tank unit, main controller PCB
<Countermeasure>
1) Check the operation method
Make sure to have the ink tank cover closed
2) Visual check
If the ink tank cover is damaged or deformed, replace it.
3) Replace the ink tank unit.
4) Replace the main controller PCB.
6.1.2.6 End of paper feed. Cannot feed paper more.
0012-6615
iPF9000
<Cause>
In the manual feed mode, the main controller detected that the roll media had been fed by the maximum amount.
Maximum backward feed amount: Printing standby position (on the feed roller)
Maximum forward feed amount: Until the media sensor detects absence of roll media.
<Probable fault location>
Media, media sensor, main controller PCB
<Countermeasure>
1) Media check
If there is any damage or break on the media or the media size is not the specified one, replace the media.
2) Media loading position check
If the media loading position is wrong, load the media again.
3) Media sesor
Check for normal operation. If the operation is abnormal, replace the media sensor.
4) Replace the main controller PCB.
6.1.2.7 Paper Type Wrong
0014-9444
iPF9000
* Occurs as a warning when "ON" is selected for "Ignore Mismatch".
<Cause>
The type of the loaded media was different from the media type specified on the driver.
<Probable fault location>
Media, main controller PCB
<Countermeasure>
1) Media check
Load correct media type.
2) Replace the main controller PCB
6.1.2.8 GARO W12xx
0013-2101
iPF9000
Either of the following numbers will be displayed for "xx" (21, 22, 23, 25, 31, 32, 33, 34, 35)
<Cause>
The GARO command in the received data was invalid.
<Probable fault location>
Operation method or main controller
<Countermeasure>
1) Check the operation method and retry printing.
2) Replace the main controller PCB.
6.1.2.9 Check printed document.
0014-9213
iPF9000
<Cause>
The number of non-discharging nozzles has exceeded the number of nozzles that can back up the non-discharging.
<Probable fault location>
Printhead, head management sensor, head relay PCB, carriage relay PCB, main controller PCB
Summary of Contents for iPF9000 series
Page 1: ...Aug 8 2007 Service Manual iPF9000 series ...
Page 2: ......
Page 6: ......
Page 13: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 14: ......
Page 25: ...Chapter 1 1 9 F 1 13 ...
Page 102: ...Chapter 1 1 86 ...
Page 103: ...Chapter 1 1 87 ...
Page 104: ......
Page 105: ...Chapter 2 TECHNICAL REFERENCE ...
Page 106: ......
Page 172: ......
Page 173: ...Chapter 3 INSTALLATION ...
Page 174: ......
Page 176: ......
Page 218: ...Chapter 3 3 42 F 3 85 6 FAN UNIT 7 FAN UNIT A ...
Page 231: ...Chapter 3 3 55 F 3 107 6 FAN UNIT 7 FAN UNIT A ...
Page 233: ...Chapter 3 3 57 ...
Page 234: ......
Page 235: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Page 236: ......
Page 238: ......
Page 273: ...Chapter 4 4 35 ...
Page 274: ......
Page 275: ...Chapter 5 MAINTENANCE ...
Page 276: ......
Page 278: ......
Page 285: ...Chapter 5 5 7 ...
Page 286: ......
Page 287: ...Chapter 6 TROUBLESHOOTING ...
Page 288: ......
Page 354: ......
Page 355: ...Chapter 7 SERVICE MODE ...
Page 356: ......
Page 358: ......
Page 420: ......
Page 421: ...Chapter 8 ERROR CODE ...
Page 422: ......
Page 424: ......
Page 431: ...Aug 8 2007 ...
Page 432: ......