COPIER> OPTION> CLEANING

OHP-PTH

Set of ITB clean transp threshold value

Lv.2 Details

When a large number of transparencies is fed, surface active agent 

which coats the surface of an transparency adheres to the ITB, and 

consequently the transfer efficiency is lowered, causing an image 

failure. After feeding a certain number of transparencies, a patch 

is formed on the ITB, and the ITB Cleaning Blade scrapes it off 

together with surface active agent.

This setting is used to set the threshold value for the number of fed 

transparency which is the condition to execute ITB cleaning.

Use case

When an image failure occurs due to lowering of the transfer 

efficiency

Adj/set/operate method 1) Enter the setting value, and then press OK key.

2) Turn OFF/ON the main power switch.

Display/adj/set range

0 to 100

0: Not executed

Unit

Number of sheets

Default value

15

Related service mode

COPIER> FUNCTION> CLEANING> TBLT-CLN

W-CLN-PH

ON/OFF of Charging Wire auto cleaning

Lv.2 Details

To set ON/OFF of automatic cleaning of the Primary Charging Wire 

and Pre-transfer Charging Wire.

Adj/set/operate method 1) Enter the setting value, and then press OK key.

2) Turn OFF/ON the main power switch.

Display/adj/set range

0 to 1

0: OFF, 1: ON

Default value

1

Related service mode

COPIER> OPTION> CLEANING> W-CLN-P, W-CLN-T

T-5-68

 

ENV-SET

COPIER> OPTION> ENV-SET

ENVP-INT

Temp, humid &Fix Belt temp log get cycle

Lv.1 Details

To set the cycle to obtain log of the humidity inside the machine and 

the surface temperature of the Fixing Belt.

As the value is incremented by 1, the cycle is increased by 1 minute. 

Obtained log can be displayed by selecting the following: COPIER > 

DISPLAY > ENVRNT

Use case

At trouble analysis

Adj/set/operate method 1) Enter the setting value, and then press OK key.

2) Turn OFF/ON the main power switch.

Display/adj/set range

0 to 480

Unit

1 minute

Default value

60

Related service mode

COPIER> DISPLAY> ENVRNT

DRY-CISU

ON/OFF of condensation prevention mode

Lv.1 Details

To set ON/OFF of condensation mode.

When droplets are appeared on the Scanner Unit due to 

condensation and image failure or E225 occurs, set “1: ON”. 

By selecting 1, the Scanner Unit (paper front) stops the fan for 

15 seconds and the Scanner Unit (paper back) lights LED for 30 

seconds from the next startup.  

Use case

When droplets are appeared on the Scanner Unit due to 

condensation and image failure or E225 occurs

Display/adj/set range

0 to 1

0: OFF (Normal mode), 1: ON (Anti-condensation mode)

T-5-69

Summary of Contents for imageRUNNER ADVANCE 9070 PRO series

Page 1: ...8 7 6 5 4 3 2 1 imageRUNNER ADVANCE C9075 PRO 9070 PRO 9065 PRO 9060 PRO C7065 7055 Series Rev 6 0 Service Manual Digest ...

Page 2: ...nformation as the need arises In the event of major changes in the contents of this manual over a long or short period Canon will issue a new edition of this manual The following paragraph does not apply to any countries where such provisions are inconsistent with local law Trademarks The product names and company names used in this manual are the registered trademarks of the individual companies ...

Page 3: ...switch closing the front door and closing the delivery unit door which results in supplying the machine with power 2 In the digital circuits 1 is used to indicate that the voltage level of a given signal is High while 0 is used to indicate Low The voltage value however differs from circuit to circuit In addition the asterisk as in DRMD indicates that the DRMD signal goes on when 0 In practically a...

Page 4: ...A1 Color Image Reader A1 3 154 Paper Deck Unit A1 3 155 POD Deck Light A1 3 155 Multi drawer Paper Deck A1 3 156 Buffer Path Unit F1 3 157 Insertion Unit H1 3 158 Professional Puncher C1 Professional Puncher Integration Unit B1 3 159 Insertion Unit J1 3 160 Paper Folding Unit G1 3 161 Paper Folding Insertion Unit G1 3 162 External 2 hole Puncher A1 External 2 3 Hole Puncher A1 External 2 4 Hole Pu...

Page 5: ...5 546 6 Parts Replacement and Cleaning List of Parts 6 2 List of Main Unit 6 2 List of Clutch Solenoid 6 10 List of Motor 6 12 List of Fan 6 22 List of Sensor 6 25 Lamp Heater others 6 34 List of Switch 6 38 List of PCB 6 41 Connector List 6 52 7 Product Overview Specifications 7 2 Specifications of main unit 7 2 Productivity print speed 7 3 Paper type 7 4 Product lineups 7 6 Main unit 7 6 Pickup ...

Page 6: ... of Laser System Turn power switch ON Points to Note About Turning Off the Main Power Switch Safety of Toner Notes When Handling a Lithium Battery Notes Before it Works Serving imageRUNNER ADVANCE C9075 PRO 9070 PRO 9065 PRO 9060 PRO C7065 7055 Series ...

Page 7: ...ay be used for a different product Laser Safety Laser beam radiation may pose a danger to the human body A laser scanner mounted on the machine is sealed with the protection housing and external cover to prevent the laser beam from leaking to the outside The laser beam never leaks out of the scanner as far as users operate the machine normally This product is certificated as a Class 1 laser produc...

Page 8: ...small amounts of dye Do not throw toner into fire It may cause explosion Toner on Clothing or Skin If your clothing or skin has come into contact with toner wipe it off with tissue then wash it off with water Do not use warm water which will cause the toner to jell and fuse permanently with the fibers of the cloth Tonner is easy to react with plastic material avoid contact with plastic Notes When ...

Page 9: ...1 1 Periodical Service Periodical Service Operation Item ...

Page 10: ... it with alcohol and lint free paper Execute this when replacing the Color Drum Unit 7 Toner Blocking Plastic sheet 4 Δ Clean it with lint free paper 8 Primary Charging Wire FL2 8915 1 PRDC 1 PRM WIRE 9 Primary Charging Wire Cleaning Pad Slider FL2 0462 1 PRDC 1 PRM CLN 10 Primary Charging Wire Cleaning Pad Holder FL2 2720 1 PRDC 1 PRM CLN2 11 Pre transfer Charging Wire FL2 8807 1 PRDC 1 PO WIRE 1...

Page 11: ...it with alcohol and lint free paper Execute this when replacing the ITB 30 ITB HP Sensor 1 Δ Clean it with blower brush Execute this when replacing the ITB 31 ITB Displacement Sensor 1 Δ Clean it with blower brush Execute this when replacing the ITB 32 ITB Cleaning Unit 1 Remove the toner piled up on the back of Scoop up Sheet when replacing the ITB Cleaning 33 ITB FY7 0409 1 DRBL 1 TR BLT 34 ITB ...

Page 12: ...ng Belt Unit FM4 5701 1 DRBL 1 FX BLT U 50 Pressure Belt Unit FM4 5702 1 DRBL 1 FX BLT L 51 Pickup Feeding System Right Deck Pickup Roller FC5 2524 1 DRBL 1 C1 PU RL 52 Left Deck Pickup Roller FC5 2524 1 DRBL 1 C2 PU RL 53 Right Deck Feed Roller FC5 2526 1 DRBL 1 C1 FD RL 54 Left Deck Feed Roller FC5 2526 1 DRBL 1 C2 FD RL 55 Right Deck Separation Roller FC5 2528 1 DRBL 1 C1 SP RL 56 Left Deck Sep...

Page 13: ...2 2 Adjustment Overview When replacing parts When clearing RAM ...

Page 14: ...Sensor p 2 9 ITB Cleaning Blade Unit p 5 11 ITB p 2 12 Primary Transfer Roller p 2 12 Patch Sensor Unit p 2 12 Waste Toner Container p 2 12 Waste Toner Full Sensor p 2 12 Fixing System Fixing belt Unit p 2 12 Pressure belt Unit p 2 12 Fixing assembly p 2 13 When replacing parts Controller System Main Controller PCB 1 Procedure of parts replacement Refer to Chapter 4 Removing the Main Controller PC...

Page 15: ... the accuracy of connector connection when slotting in this service part is provided with the PCB being installed to the frame 1 Before Replacing Perform the following operations Be sure to get an approval from the user beforehand 1 Backup of the set registered data Use the Remote UI Management Settings Data Management Import Export Target data Address List Forwarding Settings Settings Registratio...

Page 16: ...nt 3 After Replacing 1 After installing the parts turn ON the main power switch 2 Restoring the backup data Use the Remote UI Management Settings Data Management Import Export 3 Resetting registering the data While referring to the list of set registered data which was printed out before replacement reset register the data 4 When the user generates and adds the encryption key certificate and or CA...

Page 17: ...on When using the Card Reader and imageWARE Accounting Manager Card ID used for imageWARE Accounting Manager is stored in the HDD so NSA collection control is not enabled after the HDD replacement After the HDD is replaced reinstall the card ID from imageWARE Accounting Manager using the following procedures 1 Go to COPIER FUNCTION INSTALL CARD and enter the numerical value of the leading card whi...

Page 18: ...13 Laser Exposure System Laser Scanner Unit Procedure of parts replacement Refer to Chapter 0 Removing the Laser Scanner Unit Procedure of adjustment 1 Execute the initial position adjustment of the Skew Correction Motor COPIER FUNCTION LASER LD ADJ Y M C 2 Execute the color displacement correction Additional Functions Setup Register Adjustment Maintenance Image Adjustment Color Displacement Corre...

Page 19: ...install the Primary Charging Assembly to the Host Machine and then output the test print to check the image Procedure of adjustment 4 Adjust the Primary Charging Assembly in the case of dark image at the rear side on the test print NOTE In the case of dark image at the rear side of the test print 2 execute step 4 1 through 4 3 below until the density gets even Then if there is no density unevennes...

Page 20: ... and the Drum Unit Y M C Procedure of adjustment 1 Disable OFF the warm up rotation COPIER FUNCTION INSTALL AINR OFF 2 Turn OFF the main power switch Replace the Drum 3 Turn ON the main power switch 4 Forcible execution of Drum replacement mode COPIER FUNCTION DPC DRMRSETY M C K 5 Enable ON the warm up rotation COPIER FUNCTION INSTALL AINR OFF Developing Assembly Procedure of parts replacement Ref...

Page 21: ...2 bosses in the boss holes on the main unit F 2 1 T 2 22 Procedure of adjustment 2 Install the ITB Unit to the main unit NOTE Purpose to remove the ITB Unit in this procedure is to prevent the ITB from a damage caused by dropping a part 3 Connect a new cable to the connector on new electric potential sensor 4 Install the electric potential sensor by aligning with the boss A of the electrode for th...

Page 22: ... Saddle T 2 24 Procedure of adjustment 7 Place the electrode for electric potential sensor check on the Process Unit Inner Cover and clip the metal plate of the hinge area with the clip of the electrode to connect the grounding 1 ground Ground Electrode for the Potential Sensor Check Caution Check that the electrode for the Potential Sensor check is secured in place 8 Close the multi door Caution ...

Page 23: ...Counter Test Option Function Adjust I O Display OK OFST OK DPC DRM RSET OFST Y OFST M DRMRSETY OFST C DRMRSETM DPC READY LEVEL 1 1 2 Counter Test Option Function Adjust I O Display 14 Cancel to disable the pre rotation with the service mode Set to 0 with Service mode COPIER FUNCTION INSTALL AINR OFF 15 Turn the main power switch OFF 16 Install a new electric potential sensor to the Primary Chargin...

Page 24: ...te the offset adjustment of Waste Toner Full Sensor COPIER FUNCTION MISC P WTN OFST Waste Toner Full Sensor Procedure of parts replacement Refer to Chapter 6 List of Sensor Procedure of adjustment 1 Install the Waste Toner Container 2 Execute the offset adjustment of Waste Toner Full Sensor COPIER FUNCTION MISC P WTN OFST Fixing belt Unit Procedure of parts replacement Refer to Chapter 4 Removing ...

Page 25: ...eel of the Pressure Belt Position Sensor and the oil spilled from the Pressure Belt with lint free paper Pressure Sub Thermistor2 Contact Wheel 3 Clean the Inlet Guide and Sensor Flag with lint free paper moistened with alcohol 4 Clear the counter COPIER COUNTER DRBL 1 FX BLT L NOTE When the foregoing counter clear is executed the following item is cleared COPIER DISPLAY FIXING FX U TM1 8 COPIER D...

Page 26: ... foregoing counter clear is executed the following item is cleared COPIER COUNTER FIXING FX CNT COPIER DISPLAY FIXING FX U TM1 8 FX L TM1 8 FX U STR FX MTR2 8 T 2 36 When clearing RAM When clearing RAM Procedure of adjustment Before clearing RAM COPIER FUNCTION SYSTEM DSRAMBUP After clearing RAM COPIER FUNCTION SYSTEM DSRAMRES T 2 37 ...

Page 27: ...3 3 Error Code Over View Location Code Error Code Jam Code Alarm Code ...

Page 28: ...with the following pickup position code In the jam display screen the P row corresponds to the pickup position code Pickup position Pickup position code At Finisher jam At error avoidance jam At ADF jam without pickup operation at SEND Inbox etc 0 Right deck 1 Left deck 2 Cassette 3 3 Cassette4 4 Multi purpose Tray 5 Side Paper Deck 6 Duplex At duplex printing jam occurs after paper passes through...

Page 29: ...fter startup of pressure belt temperature control Measures Check if the detection temperature of the thermistor is risen in service mode COPIER DISPLAY ANALOG FIX xx A In case that either one of the thermistor detection temperature is risen A 1 Check the pressure belt main thermistor to see if the thermistor is disconnected the harness of the thermistor is disconnected foreign substance is in the ...

Page 30: ... B 2 Replace the DC controller PCB NOTE After performing the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E001 0011 05 Title Fixing main thermistor abnormal temperature rise circuit abnormality Description of detection Fixing main thermistor THM1 1 detected abnormal high temperature software detection ...

Page 31: ... Replace the DC controller PCB NOTE After performing the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E001 0103 05 Title Abnormal temperature rise of pressure subthermistor 2 THM4 circuit failure Description of detection Pressure subthermistor 2 THM4 sensed an abnormal high temperature ASIC detection M...

Page 32: ...the pressure stay B In case that the detection temperature is other than 250 degC B 1 The pressure main thermistor is disconnected the harness is disconnected foreign substance is gotten in or failure replace the main thermistor or pressure stay B 2 Replace the DC controller PCB NOTE After performing the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code...

Page 33: ... performing the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E002 0004 05 Title Insufficient fixing belt temperature rise 3 Description of detection In a warm up the temperature of fixing main thermistor THM1 1 does not reach to 130 degrees Celsius within 120 seconds after reaching to 110 degrees Celsi...

Page 34: ...orming the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E002 0006 05 Title Insufficient fixing belt temperature rise 5 Description of detection In a warm up the temperature of fixing main thermistor THM1 1 does not reach to the specified temerature for temperature control after reaching to 150 degrees ...

Page 35: ...following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E003 0001 05 Title Fixing belt abnormally low temperature Description of detection After standby fixing main thermistor THM1 1 detected less or equal to 130 degrees Celsius in succession for ten seconds Measures 1 Check the rear louver If the rear of the machine is close to the wall tempera...

Page 36: ...fter performing the above remedy work go through the following to clear the error COPIER FUNCTION CLEAR ERR E code Detailed code Occurance area Items Description E003 0003 05 Title Perssure belt abnormally low temperature Description of detection After went in standby Pressure sub thermistor 1 THM3 detected less or equal to 50 degrees Celsius for specified period of time 250sec Measures Check if t...

Page 37: ...board replacement E code Detailed code Occurance area Items Description E004 0201 05 Title Fixing belt temperature difference error 1 Description of detection Difference of detected temperature between the fixing subthermistor 2 THM1 3 and the fixing subthermistor 1 THM1 2 is bigger than the rated value Measures 1 Fixing main sub thermistor THM1 1 2 3 connector disconnetion pinching wire broken wi...

Page 38: ...ace the DC controller PCB E004 0301 05 Title IH overcurrent detection error Description of detection Detected an overcurrent on IH power supply board Measures 1 Faulty fixing belt unit replace the fixing belt unit 2 Faulty fixing IH unit replace the fixing IH unit 3 Faulty IH power PCB replace the IH power PCB E code Detailed code Occurance area Items Description E004 0401 05 Title 12V failure err...

Page 39: ...lacement direction is unknown Description of detection Full displacement of the fixing belt was detected but the displacement direction front rear was unknown Measures 1 Forgot to clear the counter at the fixing belt replacement clear the counter 2 Check physical relationship between the fixing belt position sensor 1 2 PS71 72 and the sensor flag A In case that both sensors are blocked from light ...

Page 40: ...ector or replace the fixing drawer cable 5 Faulty fixing feed driver PCB replace the fixing feed driver PCB E code Detailed code Occurance area Items Description E007 0021 05 Title Fixing belt displacement failure rear side Description of detection It was detected that the fixing belt was displaced to the position of Rear 2 rear side at 3 mm from the center Measures 1 Forgot to clear the counter a...

Page 41: ...PCB or the connector is physically removed if it is open circuit replace 2 Check if the installation of the fixing belt position sensor 1 2 is inappropriate 3 Faulty fixing belt position sensor 1 2 replace the sensor 4 Faulty fixing belt unit replace the fixing belt unit E code Detailed code Occurance area Items Description E007 9902 05 Title Pressure belt displacement failure Full displacement of...

Page 42: ...r Prior to Controller Version 1x xx Description of detection A This error occurs when the Drum Speed Detection PCB Y 1 2 signal error is detected B The lock signal for the drum motor Y M21 cannot be detected within a specified period Connector disconnected Breaking Breaking shorting Drum unit not inserted Drum unit failure Encoder failure This occurs in very rare cases E code Detailed code Occuran...

Page 43: ...m speed detection PCB E code Detailed code Occurance area Items Description E012 0103 05 Title Drum Speed Detection PCB Y 2 signal error Description of detection The signal is not detected for 80 msec or more Measures 1 Check the connection of the Drum Speed Detection PCB Y 2 UN21 Sensor side J7316 J7317 J8016 PCB side J1910 2 Take out the Drum Speed Detection PCB Y 2 to clean 3 Replace the Drum S...

Page 44: ...ion PCB M 1 2 is properly installed A 3 Check the connection of the Drum ITB Driver PCB UN6 PCB side J1910 A 4 Take out the Drum Speed Detection PCB M 1 2 to clean the Drum Speed Detection PCB M 1 2 and Encoder Wheel A 5 Replace the Drum Speed Detection PCB M 1 2 A 6 Replace the Drum ITB Driver PCB B B 1 Check the connection of the drum motor M M23 Connection of the connector Breaking Breaking sho...

Page 45: ...ion PCB E code Detailed code Occurance area Items Description E012 0203 05 Title Drum Speed Detection PCB M 2 signal error Description of detection The signal is not detected for 80 msec or more Measures 1 Check the connection of the Drum Speed Detection PCB M 2 UN23 Sensor side J7314 J7315 J8013 PCB side J1910 2 Take out the Drum Speed Detection PCB M 2 to clean 4 Replace the Drum Speed Detection...

Page 46: ...s properly installed A 3 Check the connection of the Drum ITB Driver PCB UN6 PCB side J1910 A 4 Take out the Drum Speed Detection PCB C 1 2 to clean the Drum Speed Detection PCB C 1 and Encoder Wheel A 5 Replace the Drum Speed Detection PCB C 1 2 A 6 Replace the Drum ITB Driver PCB B B 1 Check the connection between the drum motor C M25 and the drum ITB driver PCB UN6 Connection of the connector B...

Page 47: ...rum speed detection PCB E code Detailed code Occurance area Items Description E012 0303 05 Title Drum Speed Detection PCB C 2 signal error Description of detection The signal is not detected for 80 msec or more Measures 1 Check the connection of the Drum Speed Detection PCB C 2 UN25 Sensor side J7312 J7313 J8012 PCB side J1910 2 Take out the Drum Speed Detection PCB C 2 to clean 3 Replace the Drum...

Page 48: ...nstalled A 3 Check the connection of the Drum ITB Driver PCB UN6 PCB side J1911 A 4 Take out the Drum Speed Detection PCB Bk 1 2 to clean the Drum Speed Detection PCB Bk 1 2 and Encoder Wheel A 5 Replace the Drum Speed Detection PCB Bk 1 2 A 6 Replace the Drum ITB Driver PCB B B 1 Check the connection between the drum motor Bk M19 and the drum ITB driver PCB UN6 Connection of the connector Breakin...

Page 49: ...face of the drum speed detection PCB E code Detailed code Occurance area Items Description E012 0403 05 Title Drum Speed Detection PCB Bk 2 signal error Description of detection The signal is not detected for 80 msec or more Measures 1 Check the connection of the Drum Speed Detection PCB Bk 2 UN19 Sensor side J7310 J7311 PCB side J1911 2 Take out the Drum Speed Detection PCB Bk 2 to clean 4 Replac...

Page 50: ... Rotation Sensor Encoder Wheel rotates If the Encoder Wheel does not rotate replace the Drum Drive Unit A 5 Take out the ITB Drive Roller Speed Detection PCB 1 2 to clean the ITB Drive Roller Speed Detection PCB 1 2 and Encoder Wheel A 6 Replace the ITB Drive Roller Speed Detection PCB 1 2 A 7 Replace the Drum ITB Driver PCB B B 1 Check the connection between the ITB driver motor M3 and the drum I...

Page 51: ... Check if the Harness of the ITB Drive Roller Speed Detection PCB 1 is faulty Replace the Harness if it s disconnected A 5 Replace the Drum ITB Driver PCB UN6 B B 1 Check the connection between the ITB driver motor M3 and the drum ITB driver PCB UN6 Connection of the connector Breaking Breaking shorting Motor side J7518 J8047 J8050 PCB side J1921 J8011 J8050 B 2 Check the connection of the ITB dri...

Page 52: ...easures 1 Check the connection between the ITB Drive Motor and Drum ITB Driver PCB UN6 Sensor side J7518 J8047 J8050 PCB side J1912 J8011 2 Check the ITB Check to see if the ITB is displaced or ripped Refer to E075 if the ITB is displaced 3 Replace the ITB Cleaning Blade 4 Replace the Drum ITB Driver PCB E code Detailed code Occurance area Items Description E012 2000 05 Title Rotation error of Dru...

Page 53: ...f detection The sensor sampling result is not within a specified range Measures If the waste toner bottle is full of toner if toner is viewable at the height of the detection window go to Step 1 If the waste toner bottle is not full of toner if toner is not viewable at the height of the detection window and the detection window is stained with toner go to Step 2 If the toner bottle is new go to St...

Page 54: ...e If there is power output factor other than power supply can be the cause of the error 1 Check the fixing unit drive gear replace the gear 2 Replace the fixing motor M48 3 Replace the fixing feed driver PCB 4 Check the connection of the 38 V Power Supply connector 5 Replace the 38 V Power Supply 6 Replace the DC controller PCB E014 0002 05 Title Fixing motor error At regular rotation Description ...

Page 55: ...t are applied to the ITB If many scratches are found replace the ITB If dirt is applied clean the ITB In this case check the ITB cleaning blade at the same time 5 Replace the patch sensor unit E code Detailed code Occurance area Items Description E020 0082 05 Title Patch sensor light intensity correction error Description of detection When executing correction of patch sensor light intensity the P...

Page 56: ...ch shutter 5 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0130 05 Title Initia...

Page 57: ... on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0136 05 Title Initial installation patch Y sampling error Description of detection When executing developing assembly initial installation mode COPIER FUNCTION INSTALL INISET Y the variation before average patch P wave light intensity is more than...

Page 58: ...f COPIER DISPLAY DENS P LED DA is large 153 D or more and the value of COPIER DISPLAY DENS P SENS P is small there is a high possibility that dirt is applied to the patch sensor This occurs only at a regular timing When the value of COPIER DISPLAY DENS DENS S x is small 2 digits there is a high possibility that breaking occurred 1 Check whether the developing assembly and the drum unit are properl...

Page 59: ...2 J8035 PCB side J1242 4 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 5 Replace the patch sensor unit 6 Replace the developing assembly Check whether there is not uneven coating on the developing sleeve ...

Page 60: ...ch shutter 5 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0230 05 Title Initia...

Page 61: ... on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0236 05 Title Initial installation patch M sampling error Description of detection When executing developing assembly initial installation mode COPIER FUNCTION INSTALL INISET M the variation before average patch P wave light intensity is more than...

Page 62: ...he value of COPIER DISPLAY DENS P LED DA is large 153 D or more and the value of P SENS P is small there is a high possibility that dirt is applied to the patch sensor This occurs only at a regular timing When the value of COPIER DISPLAY DENS DENS S x is small 2 digits there is a high possibility that breaking occurred 1 Check whether the developing assembly and the drum unit are properly installe...

Page 63: ...2 J8035 PCB side J1242 4 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 5 Replace the patch sensor unit 6 Replace the developing assembly Check whether there is not uneven coating on the developing sleeve ...

Page 64: ...hutter 5 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0330 05 Title Initial in...

Page 65: ...assembly initial installation mode COPIER FUNCTION INSTALL INISET C the variation before average patch P wave light intensity is more than 100 Measures When the value of COPIER DISPLAY DENS P LED DA is large 153 D or more and the value of P SENS P is small there is a high possibility that dirt is applied to the patch sensor This occurs only at a regular timing When the value of COPIER DISPLAY DENS...

Page 66: ...he value of COPIER DISPLAY DENS P LED DA is large 153 D or more and the value of P SENS P is small there is a high possibility that dirt is applied to the patch sensor This occurs only at a regular timing When the value of COPIER DISPLAY DENS DENS S x is small 2 digits there is a high possibility that breaking occurred 1 Check whether the developing assembly and the drum unit are properly installe...

Page 67: ...J8035 PCB side J1242 4 Clean or replace the ITB Check whether the ITB belt is dirty or not If it is dirty perform cleaning with the service mode COPIER FUNCTION CLEANING TBLT CLN If it is assumed that this error occurred due to scratches on the ITB replace the ITB 5 Replace the patch sensor unit 6 Replace the developing assembly Check whether there is not uneven coating on the developing sleeve E ...

Page 68: ... due to scratches on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0434 05 Title Initial installation patch Bk density upper limit error Description of detection When executing developing assembly initial installation mode COPIER FUNCTION INSTALL INISET K the ATR patch output SigD is more than 97...

Page 69: ...at this error occurred due to scratches on the ITB replace the ITB 6 Replace the patch sensor unit 7 Replace the developing assembly E code Detailed code Occurance area Items Description E020 0490 05 Title Patch Bk density lower limit error Description of detection The ATR patch detection output SigD is less than 79 Measures When the value of COPIER DISPLAY DENS P LED DA is large 153 D or more and...

Page 70: ...85 M sensor side J7134 J8029 J8088 PCB side J1240 J8085 C sensor side J7135 J8030 J8089 PCB side J1240 J8086 Bk sensor side J7146 J8015 J8117 PCB side J1240 J8086 2 Check whether disconnection or shorting of the toner density sensor occurs or not 3 Replace the developing assembly E code Detailed code Occurance area Items Description E020 04A2 05 Title Toner density sensor Bk output upper limit err...

Page 71: ... developing assembly Y 3 Replace the DC controller interface PCB 4 Replace the developing sleeve drive motor Y E code Detailed code Occurance area Items Description E021 0201 05 Title Developing sleeve drive motor M error Description of detection The lock signal of the developing sleeve drive motor M M22 cannot be detected within a specified period Connector disconnected breaking shorting Failure ...

Page 72: ...bly C 3 Replace the DC controller interface PCB 4 Replace the developing sleeve drive motor C E code Detailed code Occurance area Items Description E021 0401 05 Title Developing sleeve drive motor Bk error Description of detection The lock signal of the developing sleeve drive motor Bk M18 cannot be detected within a specified period Connector disconnected breaking shorting Failure of the developi...

Page 73: ...isconnected breaking shorting Failure of the drum cleaning unit Overload Failure of the waste toner feed screw Overload Failure of the DC controller interface PCB Fuse FU5 burns Failure of the drum cleaning waste toner feed drive motor Measures 1 Check the connection between the drum cleaning waste toner feed drive motor and the DC controller interface PCB UN2 Connection of the connector Breaking ...

Page 74: ...nterface PCB 4 Check the contact of the drawer connector J8031 5 Replace the developing stirring motor M E code Detailed code Occurance area Items Description E023 0202 05 Title Developing stirring motor M error Description of detection Lock signal of Developing stirring motor M M28 cannot be detected for the specified period of time after first detection Connector disconnected breaking shorting F...

Page 75: ...place the developing stirring motor Bk E code Detailed code Occurance area Items Description E023 0402 05 Title Developing stirring motor Bk error Description of detection Lock signal of Developing stirring motor Bk M29 cannot be detected for the specified period of time after first detection Connector disconnected breaking shorting Failure of the developing assembly Sleeve overloaded Failure of t...

Page 76: ...ection between the release holder shift cam HP sensor PS8 and the hopper driver PCB Sensor side J7123 J8106 PCB side J1340 3 Replace the toner container drive motor 4 Clean and replace the release holder shift cam HP sensor 5 Replace the hopper unit CAUTION As for Remedy 5 since it is difficult to identify the cause it is recommended to replace the unit NOTE After performing the above remedy work ...

Page 77: ...djustment Maintenance Replace Specified Toner and check that toner replacement can be performed normally E code Detailed code Occurance area Items Description E025 01B0 05 Title Error in Y Toner Container Reciprocation HP Sensor PS11 Description of detection Unable to detect the change in the Release Holder Shift Cam HP Sensor status OFF ON when closing the cap so that open and close status of the...

Page 78: ...teps 5 Clear the error in service mode COPIER FUNCTION CLEAR ERR and then turn OFF and then ON the main power 6 Replace the toner reinstall the removed Toner Container at least once in user mode Adjustment Maintenance Replace Specified Toner and check that toner replacement can be performed normally E code Detailed code Occurance area Items Description E025 0200 05 Title Toner bottle motor lock M ...

Page 79: ...ide J1390 4 Replace the toner container inserting inlet cover open close sensor E code Detailed code Occurance area Items Description E025 02A0 05 Title Error in M Toner Container Reciprocation HP Sensor PS14 Description of detection Unable to detect the change in the Release Holder Shift Cam HP Sensor status ON OFF when opening the cap so that open and close status of the cap cannot be judged Mea...

Page 80: ...d normally E code Detailed code Occurance area Items Description E025 02C0 05 Title Error in M Toner Insertion Inlet Cover Sensor PS13 Description of detection Unable to detect opening of the Toner Insertion Inlet Cover when removing the Toner Container Measures Identify the cause of the error whether it is due to link mechanism to open the Toner Insertion Inlet Cover or problem at the Toner Inser...

Page 81: ...mended to replace the unit E code Detailed code Occurance area Items Description E025 0310 05 Title Toner container sealing release holder shift cam HP sensor timeout C error Description of detection HP sensor of release holder shift cam cannot detect within specified period of time Measures 1 Check the connection of the toner container drive motor M16 harness Check whether the wire is not caught ...

Page 82: ...djustment Maintenance Replace Specified Toner and check that toner replacement can be performed normally E code Detailed code Occurance area Items Description E025 03B0 05 Title Error in C Toner Container Reciprocation HP Sensor PS17 Description of detection Unable to detect the change in the Release Holder Shift Cam HP Sensor status OFF ON when closing the cap so that open and close status of the...

Page 83: ...teps 5 Clear the error in service mode COPIER FUNCTION CLEAR ERR and then turn OFF and then ON the main power 6 Replace the toner reinstall the removed Toner Container at least once in user mode Adjustment Maintenance Replace Specified Toner and check that toner replacement can be performed normally E code Detailed code Occurance area Items Description E025 0400 05 Title Toner bottle motor lock Bk...

Page 84: ...PCB side J1370 4 Replace the toner container inserting inlet cover open close sensor E code Detailed code Occurance area Items Description E025 04A0 05 Title Error in Bk Toner Container Reciprocation HP Sensor PS8 Description of detection Unable to detect the change in the Release Holder Shift Cam HP Sensor status ON OFF when opening the cap so that open and close status of the cap cannot be judge...

Page 85: ...d normally E code Detailed code Occurance area Items Description E025 04C0 05 Title Error in Bk Toner Insertion Inlet Cover Sensor PS7 Description of detection Unable to detect opening of the Toner Insertion Inlet Cover when removing the Toner Container Measures Identify the cause of the error whether it is due to link mechanism to open the Toner Insertion Inlet Cover or problem at the Toner Inser...

Page 86: ...stment tool is properly installed 2 Replace the potential sensor E code Detailed code Occurance area Items Description E061 0003 05 Title Potential control Vd failure Description of detection At the time of measurement of Vd at potential control the value is more than 50 V or less than 200 V against Vgrid Drum cleaning pre exposure is not performed correctly Primary charging is not performed corre...

Page 87: ...f it is damaged replace the attachment detachment drive unit FM3 4905 E code Detailed code Occurance area Items Description E075 0000 05 Title Steering HP error Description of detection The home position of the steering roller cannot be detected It cannot move from the home position Measures 1 Check the connection between the steering drive HP sensor PS3 and the ITB relay PCB UN28 Connector Breaki...

Page 88: ...driver J1550 DC controller interface PCB J1214 3 Check the connection between the secondary transfer roller detachment motor M31 and the pickup feed driver PCB UN4 Connector Breaking shorting Motor side J7003 DC controller interface side 1409 4 Check the connection between the pickup feed driver PCB and the DC controller interface PCB Connector Breaking shorting Pickup feed driver PCB J1401 DC con...

Page 89: ...e laser scanner unit 5 Replace the laser interface PCB 6 Replace the laser power relay PCB E code Detailed code Occurance area Items Description E100 0401 05 Title Laser scanner motor BD Bk error Description of detection The laser scanner motor cannot detect the VLOCK signal and PLOCK signal during BD rotation Measures 1 Check whether the cover is not opened 2 Check the connection of the relay PCB...

Page 90: ...ser interface PCB J5509 Connection of the connector Shorting Wire caught by parts 3 Replace the laser scanner unit 4 Replace the laser interface PCB 5 Replace the laser power relay PCB E code Detailed code Occurance area Items Description E110 0201 05 Title Laser scanner motor M error Description of detection The laser scanner motor cannot detect the VLOCK signal during FG rotation Measures 1 Chec...

Page 91: ...ed code Occurance area Items Description E197 0006 05 Title Serial communication error Description of detection Ex serial communication error with the DC Controller Interface PCB Measures 1 Check the connection between the DC Controller Interface PCB J1201 and the DC Controller PCB J100 2 Replace the DC Controller Interface PCB 3 Replace the DC Controller PCB E197 0007 05 Title Serial communicatio...

Page 92: ...B 3 Replace the DC Controller PCB E code Detailed code Occurance area Items Description E197 0031 05 Title Serial communication error Description of detection HOB serial communication error in the Drum ITB Driver PCB Measures 1 Check the connection between the Drum ITB Driver PCB J1901 and the DC Controller Interface PCB J1210 2 Replace the DC Controller Interface PCB 3 Replace the Drum ITB Driver...

Page 93: ... Measures 1 Check the connection between the Buffer Driver PCB J1401 and the DC Controller Interface PCB J1211 2 Replace the DC Controller Interface PCB 3 Replace the Buffer Driver PCB E197 005c 05 Title Serial communication error Description of detection Ex serial communication error with the Hopper Driver PCB Measures 1 Check the connection between the Hopper Driver PCB J1310 and the DC Controll...

Page 94: ...to the DADF driver PCB PCB1 E code Detailed code Occurance area Items Description E227 0001 04 Title Power supply 24 V error Description of detection The 24 V port is turned off at the time of power on Measures Because the DC Controller turns OFF the 24 V Power Supply when an error is detected it is needed to restart and check the power output before the machine detects the error to determine whet...

Page 95: ...er supply and Relay PCB on the Printer side 5 Replace the Reader Controller PCB and DADF Driver PCB E code Detailed code Occurance area Items Description E227 0101 04 Title Power supply 24 V error Description of detection The 24 V port is turned off at the time of power on at DADF Measures Because the DC Controller turns OFF the 24 V Power Supply when an error is detected it is needed to restart a...

Page 96: ...t each sale company bases E247 0002 00 Title System error Description of detection Measures Contact each sale company bases E code Detailed code Occurance area Items Description E247 0003 00 Title System error Description of detection Measures Contact each sale company bases E247 0004 00 Title System error Description of detection Measures Contact each sale company bases E248 0000 00 Title SRAM er...

Page 97: ...nnector of the optical unit DADF 2 Displacement disconnection of the connector of the reader controller PCB PCB1 3 Failure of the optical unit DADF 4 Failure of the reader controller PCB E280 0001 04 Title Failure of communication between the reader controller PCB PCB1 and the optical unit reader Description of detection Communication does not start between the reader controller PCB and the front ...

Page 98: ... main controller PCB E350 0000 00 Title System error Description of detection Measures Contact each sale company bases E350 0001 00 Title System error Description of detection Measures Contact each sale company bases E350 0002 00 Title System error Description of detection Measures Contact each sale company bases E code Detailed code Occurance area Items Description E350 0003 00 Title System error...

Page 99: ... motor M8 3 Failure of the tray home position sensor 4 Failure of the tray up down motor E code Detailed code Occurance area Items Description E407 0002 04 Title Failure of the tray up down motor M8 Description of detection Even when the tray up down motor M8 is driven the paper surface sensor SR6 is not turned ON within a specified period Measures 1 Displacement disconnection of the connector of ...

Page 100: ...n sensor 2 4 Failure of the detachment motor 2 5 Failure of the DADF driver PCB PCB1 E423 0001 04 Title DADF SDRAM error Description of detection SDRAM access error Measures Failure of the SDRAM video image memory located on the reader controller PCB PCB1 E423 0002 04 Title DADF SDRAM error Description of detection SDRAM Verify error Measures Failure of the SDRAM video image memory located on the ...

Page 101: ...Occurance area Items Description E503 0002 05 Title A Error in communication between the finisher saddle stitcher Finisher A1 B Error in communication between the finisher saddle stitcher Finisher B1 Description of detection A Communication failed between the finisher and the saddle stitcher B The communication with the saddle stitcher is interrupted Measures A A 1 The connector on the wiring betw...

Page 102: ...sher and the integration unit is faulty 3 The finisher controller PCB is faulty 4 The integration controller PCB is faulty E code Detailed code Occurance area Items Description E503 0042 05 Title Error in communication between the finisher integration unit Finisher A1 Description of detection Communication failed between finisher integration unit Measures 1 The connector on the cable between the f...

Page 103: ...B The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E505 0002 05 Title A Backup data error failed data writing Document Insertion Unit J1 Paper Folding Unit G1 B EEPROM error External 2 Hole Puncher A1 Description of detection A Data failed to be written properly B The checksum for the EEPROM data has an error Measures A DC controller PCB is faulty B Punch...

Page 104: ...cted 2 The wiring of the gripper HP sensor or the gripper motor are faulty 3 The gripper HP sensor is faulty 4 The gripper motor is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E514 8005 05 Title Error in the gripper motor Finisher A1 Description of detection The gripper does not come off the position sensor when the gripper motor has been dr...

Page 105: ...nd front aligning plate motor is faulty B 3 The front aligning plate is faulty B 4 The front aligning plate motor M103 is faulty B 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E530 8002 05 Title A Error in the front alignment motor Finisher A1 B Front aligning plate home position error Finisher B1 Description of detection A The front alignment HP se...

Page 106: ...ring of the stapler shift HP sensor or the staple shift motor are faulty 3 The stapler shift HP sensor is faulty 4 The staple shift motor is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E532 8001 05 Title A Error in the staple motor Finisher A1 B Stapler shift home position error Finisher B1 Description of detection A The staple unit does not...

Page 107: ...de HP sensor is faulty 4 The swing guide motor is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E535 0003 05 Title Error in the swing guide motor Finisher A1 Description of detection The swing guide height detection sensor failed to be ON even though specified period of time has passed when lowering the swing guide Measures 1 The connector of ...

Page 108: ...late is faulty B 4 The rear aligning plate motor M104 is faulty B 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E537 8002 05 Title A Error in the rear alignment motor Finisher A1 B Rear aligning plate home position error Finisher B1 Description of detection A The rear alignment HP sensor does not detect the rear alignment plate when the rear alignmen...

Page 109: ...angerous area is reached before the tray 1 paper surface sensor detects paper surface during the paper surface detection operation A discontinuous area is detected during tray operation Measures A A 1 The connectors of the tray 1 area sensors S122 S123 S124 or the tray 1 shift motor M105 are disconnected A 2 The wiring of the tray 1 area sensors or the tray 1 shift motor are faulty A 3 The tray 1 ...

Page 110: ...07 is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E540 8013 05 Title Error in the swing guide safety switch Description of detection The swing guide safety switch is turned ON while the tray 1 operates Measures 1 The connector of the swing guide safety switch front rear SW102 SW104 or the staple position switch SW103 are disconnected 2 The c...

Page 111: ... safety switch is faulty 4 The tray 2 shift motor is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E542 8004 05 Title The tray 2 shift motor clock error Finisher B1 Description of detection The FG input cannot be detected when the tray 2 shift motor has been driven for 0 2 second Measures 1 The Tray 2 shift area sensor PCB is faulty 2 The wiri...

Page 112: ...er controller PCB is faulty E551 0002 05 Title A Error in power supply fan Paper Folding Unit B Error in power supply fan FAN101 Finisher Description of detection The lock status is released when the fan stops Measures A A 1 Connector of the power supply fan is disconnected A 2 Power supply fan is faulty B B 1 The connector of the power supply fan FAN101 is disconnected B 2 The wiring of the power...

Page 113: ...faulty 3 The feed roller separation HP sensor is faulty 4 The feed roller disengage buffer flapper motor is faulty 5 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E568 8002 05 Title Error in the feed roller disengage buffer flapper motor Finisher A1 Description of detection The feed roller separation HP sensor does not detect the disengage roller when ...

Page 114: ...disconnected 2 C fold stopper motor is faulty 3 Connector of the C fold stopper HP sensor S17 is disconnected 4 C fold stopper HP sensor is faulty E code Detailed code Occurance area Items Description E56A 8002 05 Title C fold stopper motor of paper folding unit failed to return to HP Document Insertion Folding Unit Paper Folding Unit Description of detection The C fold stopper motor HP sensor S17...

Page 115: ...ining guide motor M10 is disconnected 2 Lead edge retaining guide motor is faulty 3 Connector of the lead edge retaining guide HP sensor S25 is disconnected 4 Lead edge retaining guide HP sensor is faulty E code Detailed code Occurance area Items Description E56E 8002 05 Title Lead edge retaining guide motor of paper folding unit failed to return to HP Paper Folding Unit Description of detection T...

Page 116: ... faulty E code Detailed code Occurance area Items Description E57C 8002 05 Title Error in the processing tray paper retainer motor Finisher A1 Description of detection The paper retainer HP sensor does not detect the paper retainer when the processing tray paper retainer motor has been driven for 3 seconds Measures 1 The connector of the paper retainer HP sensor S135 or the processing tray paper r...

Page 117: ...A The shutter HP sensor does not detect the shutter when the stack delivery lower shutter motor has been driven for 3 seconds B The shutter does not return to the shutter home position when the stack ejection motor has been driven for 3 seconds Measures A A 1 The connector of the shutter HP sensor S106 or the stack delivery lower shutter motor M122 are disconnected A 2 The wiring of the shutter HP...

Page 118: ... sensor is faulty A 7 The punch motor is faulty A 8 The puncher driver PCB PCB1 is faulty A 9 The finisher controller PCB is faulty B B 1 The punch home position sensor PI63 and punch motor clock sensor PI62 is faulty B 2 The wiring between the punch controller PCB and sensor is faulty B 3 The punch mechanism is faulty B 4 The punch motor M61 is faulty B 5 The punch controller PCB is faulty B 6 Th...

Page 119: ... faulty 4 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E592 8002 05 Title Trailing edge sensor error External 2 Hole Puncher Description of detection The voltage of the light received is 2 0 V or more even when the light emitting duty of the trailing edge sensor has been decreased to 0 Measures 1 The LED PCB photosensor PCB is faulty 2 The punch contr...

Page 120: ...s faulty E592 800A 05 Title Horizontal registration sensor 4 error External 2 Hole Puncher Description of detection The voltage of the light received is 2 0 V or more even when the light emitting duty of the horizontal registration sensor 4 LED4 PTR4 has been decreased to 0 Measures 1 The LED PCB photosensor PCB is faulty 2 The punch controller PCB is faulty 3 The finisher controller PCB is faulty...

Page 121: ...roller PCB PCB1 is faulty E code Detailed code Occurance area Items Description E5A3 0002 05 Title Error in the registration motor Finisher A1 Description of detection The registration HP sensor does not turn OFF when the registration motor has been driven for 0 67 msecond Measures 1 The connector of the registration HP sensor S105 or the registration motor M102 are disconnected 2 The wiring of th...

Page 122: ...e Detailed code Occurance area Items Description E5BA 8002 05 Title Error in the front estrangement motor Finisher A1 Description of detection The front estrangement motor HP sensor does not turn OFF when the front estrangement motor has been driven for 0 724 second after the front estrangement motor HP sensor has turned ON Measures 1 The connector of the front estrangement motor HP sensor S102 or...

Page 123: ...or M2 is disconnected 2 The tray lift motor is faulty 3 The connector of the paper feed sensor S3 is disconnected 4 The Paper feed sensor is faulty E code Detailed code Occurance area Items Description E5E1 8002 05 Title Tray lift motor of paper folding unit failed to return to HP Document Insertion Folding Unit Description of detection During initialization or lowering of the inserter paper feed ...

Page 124: ...me position sensor PI7 is faulty B 2 The positioning plate drive mechanism is faulty B 3 The paper positioning plate motor M4 is faulty B 4 The saddle stitcher controller PCB is faulty E code Detailed code Occurance area Items Description E5F1 8001 05 Title A Saddle folder feeder motor clock error Finisher A1 B Paper folding motor clock error Finisher B1 Description of detection A The drive speed ...

Page 125: ...home position sensor does not turn ON when the guide motor has been driven for 700 pulses Measures A A 1 The connector of the saddle roller guide HP sensor S207 or the saddle roller guide motor M204 are disconnected A 2 The wiring of the saddle roller guide HP sensor the saddle roller guide motor are faulty A 3 The saddle roller guide HP sensor is faulty A 4 The saddle roller guide motor is faulty...

Page 126: ...ate drive mechanism is faulty B 3 The aligning motor M5 is faulty B 4 The saddle stitcher controller PCB is faulty E code Detailed code Occurance area Items Description E5F3 8002 05 Title A Error in the saddle alignment guide motor Finisher A1 B Aligning plate home position error Finisher B1 Description of detection A The saddle alignment guide does not come off the saddle alignment plate HP senso...

Page 127: ...tcher HP sensor S223 or the saddle stitcher motor M209 are disconnected A 2 The wiring of the saddle stitcher HP sensor the saddle stitcher motor are faulty A 3 The saddle stitcher HP sensor is faulty A 4 The saddle stitcher motor is faulty A 5 The saddle stitcher controller PCB is faulty A 6 The finisher controller PCB is faulty B B 1 The stitcher home position sensor rear SW5 is faulty B 2 The s...

Page 128: ...3 The saddle stitcher controller PCB is faulty E code Detailed code Occurance area Items Description E5F6 8001 05 Title A Error in the saddle paper push on plate motor Finisher A1 B Paper pushing plate home position error Finisher B1 Description of detection A The saddle paper push on plate HP sensor does not detect the saddle paper push on plate when the saddle paper push on plate motor has been ...

Page 129: ...motor clock error Finisher A1 B Paper pushing plate motor clock error Finisher B1 Description of detection A The drive speed of the saddle paper push on plate motor is less than 6 clocks B The number of pulses detected by the paper pushing plate motor clock sensor is 6 pulses or less Measures A A 1 The connector of the saddle paper push on plate motor sensor S213 or the saddle paper push on plate ...

Page 130: ...4 The saddle trailing edge retainer motor is faulty 5 The saddle stitcher controller PCB is faulty 6 The finisher controller PCB is faulty E code Detailed code Occurance area Items Description E5F8 8001 05 Title Error in the saddle tapping motor Finisher A1 Description of detection The saddle paper tapping HP sensor does not detect the saddle tapping plate when the saddle tapping motor has been dr...

Page 131: ...disengage motor has been driven for 50 pulses Measures 1 The connector of the saddle lead in roller HP sensor S222 or the saddle lead in roller disengage motor M214 are disconnected 2 The wiring of the saddle lead in roller HP sensor the saddle lead in roller disengage motor are faulty 3 The saddle lead in roller HP sensor is faulty 4 The saddle lead in roller disengage motor is faulty 5 The saddl...

Page 132: ...escription of detection No font for Korea Traditional chinese and Simplified chinese Measures 1 Re installation of the system 2 HDD is faulty E code Detailed code Occurance area Items Description E602 0011 00 Title Hard disk failure Description of detection No font for Korea Traditional chinese and Simplified chinese Measures 1 Re installation of the system 2 HDD is faulty E602 0012 00 Title Hard ...

Page 133: ...ead Write level 1 Check a cable or power supply connector 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0112 00 Title Hard disk failure Description of detection FSTDEV is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to r...

Page 134: ...cute HDD CLEAR and then power cycle in the case of BOOTDEV BOOTDEV2 APL_SEND execute re format reinstallation with SST 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0200 00 Title Hard disk failure Description of detection IMG_MNG is abnormal Measures 1 Check a cable or power supply connector 2 If no...

Page 135: ...NGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0213 00 Title Hard disk failure Description of detection IMG_MNG is abnormal Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a partit...

Page 136: ...f still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0301 00 Title Hard disk failure Description of detection FSTCDEV is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then p...

Page 137: ...ecute HDD CLEAR and then power cycle in the case of BOOTDEV BOOTDEV2 APL_SEND execute re format reinstallation with SST 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0314 00 Title Hard disk failure Description of detection FSTCDEV is abnormal Measures This is an error due to data error or software b...

Page 138: ...er OFF ON 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0402 00 Title Hard disk failure Description of detection THUMDEV is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE R...

Page 139: ...d use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0421 00 Title Hard disk failure Description of detection THUMDEV is abnormal Measures This is an error that usually does not occur at ...

Page 140: ...em SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0503 00 Title Hard disk failure Description of detection APL_GEN is abnormal Measures 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to so...

Page 141: ...ce HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0522 00 Title Hard disk failure Description of detection APL_GEN is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OF...

Page 142: ...hen power cycle E code Detailed code Occurance area Items Description E602 0604 00 Title Hard disk failure Description of detection TMP_GEN is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 3 If still not recovery replac...

Page 143: ...and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0623 00 Title Hard disk failure Description of detection TMP_GEN is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 ...

Page 144: ...l Measures 1 Input applicable CHK TYPE into a partition and execute HDD CLEAR and then power cycle 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0710 00 Title Hard disk failure Description of detection TMP_FAX is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode a...

Page 145: ...2 0724 00 Title Hard disk failure Description of detection TMP_FAX is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E602 0725 00 Title Hard disk ...

Page 146: ...and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0811 00 Title Hard disk failure Description of detection TMP_PSS is abnormal Measures This is an error that usually does not occur at Read Write level 1 Check a cable ...

Page 147: ...5 00 Title Hard disk failure Description of detection TMP_PSS is abnormal Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to some dozens of minutes and then power cycle 2 If not recovery input applicable CHK TYPE into a partition and execute HDD CLEAR and then power cycle ...

Page 148: ...OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 0911 00 Title Hard disk failure Description of detection PDLDEV is abnormal Measures This is an error that usually does not occur at Read Write level 1 Check a cable or power supply connector 2 If not recovery replace HDD and re install system based on ...

Page 149: ...0 Title Hard disk failure Description of detection PDLDEV is abnormal Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to some dozens of minutes and then power cycle 2 If not recovery input applicable CHK TYPE into a partition and execute HDD CLEAR and then power cycle in t...

Page 150: ...heck a cable or power supply connector 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1012 00 Title Hard disk failure Description of detection BOOTDEV is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system S...

Page 151: ...L_SEND execute re format reinstallation with SST 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1100 00 Title Hard disk failure Description of detection APL_MEAP is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format an...

Page 152: ...NGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1113 00 Title Hard disk failure Description of detection APL_MEAP is abnormal Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a parti...

Page 153: ...e install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1201 00 Title Hard disk failure Description of detection APL_SEND is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode a...

Page 154: ...HDD failure E code Detailed code Occurance area Items Description E602 1213 00 Title Hard disk failure Description of detection APL_SEND is abnormal Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to some dozens of minutes and then power cycle 2 If not recovery input appli...

Page 155: ...f still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1301 00 Title Hard disk failure Description of detection APL_KEEP is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then ...

Page 156: ...ecute HDD CLEAR and then power cycle in the case of BOOTDEV BOOTDEV2 APL_SEND execute re format reinstallation with SST 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1314 00 Title Hard disk failure Description of detection APL_KEEP is abnormal Measures This is an error due to data error or software ...

Page 157: ...wer OFF ON 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1402 00 Title Hard disk failure Description of detection APL_LOG is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE ...

Page 158: ...d use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1421 00 Title Hard disk failure Description of detection APL_LOG is abnormal Measures This is an error that usually does not occur at ...

Page 159: ...tem SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1503 00 Title Hard disk failure Description of detection CRBDEV is abnormal Measures 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to so...

Page 160: ...ce HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 1522 00 Title Hard disk failure Description of detection CRBDEV is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF...

Page 161: ...hen power cycle E code Detailed code Occurance area Items Description E602 1604 00 Title Hard disk failure Description of detection APL_CDS is abnormal Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 3 If still not recovery replac...

Page 162: ...tem based on judging HDD failure E code Detailed code Occurance area Items Description E602 1623 00 Title Hard disk failure Description of detection APL_CDS is abnormal Measures This is an error due to data error or software bug 1 Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cycle of main power Power OFF ON 2 If not recovery re...

Page 163: ...ce HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 FF01 00 Title Hard disk failure Description of detection Abnormality of unidentified partition Measures 1 Check a cable or power supply connector 2 If not recovery Boot up in safe mode and use SST to execute full format and to re install system SYSTEM LANGUAGE RUI and then power cyc...

Page 164: ...ecute HDD CLEAR and then power cycle in the case of BOOTDEV BOOTDEV2 APL_SEND execute re format reinstallation with SST 3 If still not recovery replace HDD and re install system based on judging HDD failure E code Detailed code Occurance area Items Description E602 FF14 00 Title Hard disk failure Description of detection Abnormality of unidentified partition Measures This is an error due to data e...

Page 165: ...sed on judging HDD failure E602 FF25 00 Title Hard disk failure Description of detection Abnormality of unidentified partition Measures It is very likely that document data such as Inbox on the HDD are damaged 1 Input applicable CHK TYPE into a partition and execute HDD CHECK requires several minutes to some dozens of minutes and then power cycle 2 If not recovery input applicable CHK TYPE into a ...

Page 166: ...cription E674 0011 00 Title FAX is abnormal Description of detection FAX is abnormal Measures Main controller board replacement E674 0030 00 Title FAX is abnormal Description of detection Check sum error Measures System software download for 2 line FAX E677 0001 00 Title Print server failure Description of detection Abnormality detected on the exhaust fan operation of printer server Measures 1 Che...

Page 167: ...vendor failure Description of detection Error in IPC when CoinVendor is running In the case of disconnection of IPC or an error in which IPC communication failed to be recovered When disconnection of the pickup delivery signal is detected When illegal connection is detected short circuit with Tx and Rx of IPC Measures Check the connection between charging management equipment and machine and check...

Page 168: ... Take out the serial New Card Reader COPIER Function CLEAR CARD COPIER Function CLEAR ERR E719 0032 00 Title Communication error after the card reader a serial number startup Description of detection Communication failed in the middle of the operation although communication with the serial New Card Reader was successful at start up Measures Check if the cable of the serial New Card Reader is disco...

Page 169: ...ystem full format and installation 2 Main controller board 1 replacement E code Detailed code Occurance area Items Description E730 C001 00 Title PDL software failure Description of detection HDD access error Measures 1 System full format and installation 2 HDD replacement 3 Main controller board 1 replacement E731 3000 00 Title Image processing module failure Description of detection Image proces...

Page 170: ...reader controller PCB PCB1 3 Failure of the main controller PCB E code Detailed code Occurance area Items Description E743 0003 04 Title DDI communication error Description of detection The reader controller PCB detected a failure in communication between the main controller PCB and the reader controller PCB Measures 1 Failure of the connection between the main controller PCB and the reader contro...

Page 171: ...e machine restarts automatically E code Detailed code Occurance area Items Description E746 0033 00 Title Error in engine ID of SoftID Description of detection Error that can be recovered Measures When the TPM key was backed up it can be restored 1 Connect the USB memory which stores the TPM key 2 Go to Management Settings Data Management TPM Settings and then click Restore TPM Key 3 Enter the pas...

Page 172: ...on Main controller board 2 access errors Measures DDR2 SDRAM M0 M1 P removing and inserting replacement E748 2024 00 Title Main controller board 2 access errors Description of detection Main controller board 2 access errors Measures Main controller board 1 2 removing and inserting replacement E748 4xxx 00 Title Main controller board 2 errors Description of detection Main controller board 2 errors ...

Page 173: ...ace the IH power supply fan FM7 E code Detailed code Occurance area Items Description E804 0010 05 Title Fan error Description of detection A failure was detected at the delivery heat fan 1 FM10 Measures 1 Check the connection of the connector 2 Replace the delivery heat fan 1 FM10 0011 05 Title Fan error Description of detection A failure was detected at the delivery heat fan 2 FM11 Measures 1 Ch...

Page 174: ...r fan 2 FM20 failure E code Detailed code Occurance area Items Description E880 0005 00 Title HDD cooling fan FM21 error Description of detection When detect a failure of the power supply cooling fan Measures 1 Connector disconnection 2 HDD cooling fan FM21 failure E905 0001 05 Title POD deck light air assist fan error Description of detection Even when the maximum LOW interval was passed there wa...

Page 175: ...ir heater unit HT101 2 Failure of the air heater PCB harness 3 Failure of the upper deck air heater PCB 4 Failure of the deck driver PCB 5 Failure of the DC controller PCB in the host machine E code Detailed code Occurance area Items Description E906 0011 05 Title High temperature error at the air heater for the middle multi cassette deck Description of detection A high temperature error was detec...

Page 176: ... Failure of the AC distribution PCB F6 5 Failure of the deck driver PCB 6 Failure of the DC controller PCB in the host machine E907 0001 05 Title Multi cassette deck pickup motor error Description of detection The multi cassette deck pickup motor DC is not locked even when a specified period of time has elapsed Measures 1 Failure of the deck pickup motor M001 2 Failure of the deck driver PCB 3 Fai...

Page 177: ...hile ejecting to the escape delivery tray OTH JAM Other jams STNRY ESC Stationary jam while ejecting to the escape delivery tray STP Staple SDL STP Saddle stitch staple INIT ROT Residual at initial rotation UP DEVICE Upper stream device jam OTHER Others ERROR Error RETRY ERR Retry error STOP Press Stop key ROT Keeps rotating PROGRAM Program TIME OUT Time out PUNCH Punch MEDIA NG Misprint T 3 15 Ma...

Page 178: ... 1 PS33 ACC ID Jam Code Type Sensor Name Description Sensor ID 00 0214 STNRY Reverse Vertical Path Sensor 2 PS34 00 0215 STNRY Reverse Vertical Path Sensor 3 PS35 00 0216 STNRY Duplex Sensor 1 PS24 00 0217 STNRY Duplex Sensor 2 PS25 00 0218 STNRY Duplex Sensor 3 PS26 00 0219 STNRY Duplex Sensor 4 PS27 00 0A01 POWER ON Right Deck Pickup Sensor PS49 00 0A02 POWER ON Left Deck Pickup Sensor PS54 00 0...

Page 179: ...covered by opening and closing the Door 00 0D91 MEDIA NG Misprint paper length is short 00 0D92 MEDIA NG Misprint Although transparency setting is set paper other than transparency is fed 00 0D93 MEDIA NG Misprint Although transparency setting is not set transparency is fed 00 1E00 OTHER Finisher sequence error jam 1 The state is recovered by opening and closing the Door or turning OFF and then ON...

Page 180: ...B4 01 0049 DELAY Lead sensor 2 SR5 01 0050 STNRY Lead sensor 2 SR5 01 0051 DELAY Delivery sensor PCB5 01 0052 STNRY Delivery sensor PCB5 01 0053 DELAY 3 Reversal sensor SR23 01 0054 STNRY 3 Reversal sensor SR23 01 0071 SEQ NG 2 01 0073 ERROR 1 Disengaging HP sensor 1 SR15 01 0074 ERROR 1 Disengaging HP sensor 2 SR16 01 0075 ERROR 1 Pickup roller unit lifter HP sensor SR12 01 0090 ADF OP DADF open ...

Page 181: ...sensor PS6 00 0A1A POWER ON Deck pickup sensor PS1 00 0A1B POWER ON Deck pull out sensor PS6 F 3 4 T 3 19 Paper Deck Unit A1 PS1 PS6 ACC ID Jam Code Type Sensor Name Description Sensor ID 00 011A DELAY deck pickup sensor PS6 00 011B DELAY deck feed sensor PS1 00 021A STNRY deck pickup feed sensor PS6 00 021B STNRY deck feed sensor PS1 00 0A1A POWER ON deck pickup feed sensor PS6 00 0A1B POWER ON d...

Page 182: ...ddle deck pickup sensor S201 00 0221 STNRY Middle deck pull out sensor S202 00 0222 STNRY Lower deck pickup sensor S301 00 0223 STNRY Lower deck pull out sensor S302 00 0224 STNRY Lower deck feed sensor S004 00 0225 STNRY Vertical path upper sensor S001 00 0226 STNRY Vertical path middle sensor S002 00 0227 STNRY Vertical path lower sensor S003 00 0229 STNRY Delivery sensor S005 00 0A1E POWER ON U...

Page 183: ...Type Sensor Name Description Sensor ID 00 011C DELAY Buffer Sensor 1 PS85 00 011D DELAY Buffer Sensor 2 PS86 00 021C STNRY Buffer Sensor 1 PS85 00 021D STNRY Buffer Sensor 2 PS86 00 0A1C RESIDUAL Buffer Sensor 1 PS85 00 0A1D RESIDUAL Buffer Sensor 2 PS86 T 3 21 ...

Page 184: ...d sensor S8 02 11F6 STNRY Middle feed sensor Reverse entrance sensor S8 S18 02 11F7 STNRY Reverse sensor S17 02 11F8 STNRY Reverse timing sensor S16 02 13CC COVER OP Front upper cover open close switch Upper cover open close switch Inserter open close sensor SW1 SW2 S19 02 14CD POWER ON Detected presence of paper at power on at initialization at warm up rotation by any sensors on the feed path 02 ...

Page 185: ...1F71 RESIDUAL Idle rotation jam 02 1F78 TIME OUT Time out jam 02 1F79 SEQ NG Abnormality during receipt from upstream installation 02 1F7F STOP Press Stop key only if the finisher is connected 02 1F7B UP DEVICE Jam caused by other installation 02 1051 DELAY bypass 1 sensor RS1 02 1152 STNRY bypass 1 sensor RS1 02 1053 DELAY reverse path 1 sensor RS2 02 1154 STNRY reverse path 1 sensor RS2 02 1055 ...

Page 186: ...Y Paper registration sensor S4 02 11C2 STNRY Reverse entrance sensor S12 02 11C3 STNRY Reverse sensor S10 02 11C4 STNRY Reverse timing sensor S11 02 1FD1 OTHER No papers at the time of Inserter Tray pickup Tray paper sensor 1 Tray paper sensor 2 S7 S8 02 1FD7 POWER ON Paper registration sensor Reverse sensor Reverse timing sensor Reverse entrance sensor S4 S10 S11 S12 02 1FD8 DOOR OP Front upper c...

Page 187: ...C STNRY Upper stopper paper sensor S33 02 11FD STNRY Delivery sensor 1 S22 02 11FE STNRY Fold tray paper sensor S27 02 1FD0 TIME OUT Failed to detect OFF of EntryStart although a specified period of time has passed after replying ON of EntryStartAck 02 13DD POWER ON Detected presence of paper at power on at initialization at warm up rotation by any sensors on the feed path 02 14DC COVER OP Front u...

Page 188: ...02 10BA DELAY C fold delivery sensor S15 02 11C1 STNRY Paper registration sensor S4 02 11C2 STNRY Reverse entrance sensor S12 02 11C3 STNRY Reverse sensor S10 02 11C4 STNRY Reverse timing sensor S11 02 11C5 STNRY Slowdown timing sensor S24 02 11C6 STNRY Release timing sensor S21 02 11C7 STNRY Fold position sensor S23 02 11C8 STNRY Upper stopper sensor S22 02 11C9 STNRY Delivery sensor S25 02 11CA ...

Page 189: ...Puncher A1 PI63 PCB12 F 3 13 ACC ID Jam Code Type Sensor Name Description Sensor ID 02 1012 DELAY Trailing edge sensor LED5 PTR5 PCB11 PCB12 02 1122 STNRY Trailing edge sensor LED5 PTR5 PCB11 PCB12 02 1F44 PUNCH Punch home position sensor PI63 02 1F45 POWER ON Trailing edge sensor LED5 PTR5 PCB11 PCB12 T 3 27 ...

Page 190: ...BA during paper feed 02 1205 TIMING Inlet sensor S101 02 1307 POWER ON Inlet sensor Feed path senor S101 S102 02 1387 POWER ON Saddle inlet sensor Saddle vertical path sensor Saddle delivery sensor 1 Saddle delivery sensor 2 S201 S203 S226 S227 02 138A POWER ON Detected presence of paper at power on after opening and then closing the door by any sensors on the feed path 02 1408 DOOR OP Front door ...

Page 191: ...et sensor PI103 02 1307 POWER ON Inlet sensor Delivery sensor Escape tray path sensor PI103 PI104 PI118 02 1387 POWER ON Delivery sensor Vertical path paper sensor No 1 paper sensor No 2 paper sensor No 3 paper sensor Saddle inlet sensor PI11 PI17 PI18 PI19 PI20 PI22 02 1408 COVER OP Front cover sensor Front cover switch PI102 MSW101 02 1488 COVER OP Inlet cover sensor Front cover sensor PI9 PI102...

Page 192: ...error in LIPS 73 0024 LIPS Boot error in LIPS 73 0025 LIPS When the graphic library is in use for image processing if the memory allocation is failed 73 0026 LIPS Data format error of image mode 75 0001 Error occurred in Yukon 75 0002 Error occurred due to invalid SVG analysis from Yukon 76 0001 Font No memory for internal font 76 0002 Font Fails to assure the work area to analyze the font that is...

Page 193: ...er error Movement The left deck pickup motor M42 stops The left deck is not used Cause The left deck lifter does not move up A failure occurred in the left deck paper surface sensor PS57 Measures Turn OFF ON the power to eliminate the problem 04 0231 Cassette 3 lifter error Movement The cassette 3 pickup motor M44 stops The cassette 3 is not used Cause The cassette 3 lifter does not move up A fail...

Page 194: ... eliminate the problem 04 3045 The lower limit of the value of counting the paper remaining on the upper multi cassette deck has been exceeded Movement The upper deck lifter motor M101 stops The upper deck is not used Measures Turn OFF ON the power to eliminate the problem Alarm Code Title A movement B cause C measures 04 3145 The lower limit of the value of counting the paper remaining on the mid...

Page 195: ...ent of whether or not to replace the corresponding parts Alarm Code Title A movement B cause C measures 34 0002 Image position correction patch detection alarm 2 Movement None Cause The image position correction patch pattern cannot be detected at all Failure of the patch sensor Failure of the shutter Image failure 1 1 Check whether the color image is formed correctly for 4 colors a Perform test p...

Page 196: ...ration sensor Scratches on the belt Measures 1 Check whether a color image is formed correctly for 4 colors a Perform test print in the following condition COPIER TEST PG TYPE 6 Output one sheet for each color in the paper of LTR A4 A3 size more than 290mm in a horizontal scanning direction b Check the following points Check whether there is color displacement in a horizontal scanning direction ba...

Page 197: ...atch image failure Measures 1 Check whether a color image is formed correctly for 4 colors a Perform test print in the following condition COPIER TEST PG TYPE 6 Output one sheet for each color in the paper of LTR A4 A3 size more than 290mm in a horizontal scanning direction b Check the following points Check whether there is color displacement in a horizontal scanning direction based on the Bk sta...

Page 198: ...ob is cancelled Alarm Code Title A movement B cause C measures 75 9106 Failure in transfer of video data from an external controller When a video data transfer error occurred retransmission of the video data is internally performed so no measures need to be taken However when retransmission is performed over a specified number of times the corresponding job is cancelled 75 9107 Failure in transfer...

Page 199: ...ver when retransmission is performed over a specified number of times the corresponding job is cancelled Alarm Code Title A movement B cause C measures 75 9116 Failure in transfer of video data from an external controller When a video data transfer error occurred retransmission of the video data is internally performed so no measures need to be taken However when retransmission is performed over a...

Page 200: ...ver when retransmission is performed over a specified number of times the corresponding job is cancelled Alarm Code Title A movement B cause C measures 75 B106 Failure in transfer of video data from an external controller When a video data transfer error occurred retransmission of the video data is internally performed so no measures need to be taken However when retransmission is performed over a...

Page 201: ...ver when retransmission is performed over a specified number of times the corresponding job is cancelled Alarm Code Title A movement B cause C measures 75 B116 Failure in transfer of video data from an external controller When a video data transfer error occurred retransmission of the video data is internally performed so no measures need to be taken However when retransmission is performed over a...

Page 202: ...ning input encode error Remove and place the document decrease the sharpness level and perform printing again If this alarm occurs frequently check the connection of the DDIS video cable replace the reader and replace the video controller 2 85 0003 Scanning input encode error 2 Remove and place the document decrease the sharpness level and perform printing again If this alarm occurs frequently che...

Page 203: ...4 4 User Mode List of User Mode ...

Page 204: ... multiple machines at the same time Your machine is capable of both sending and receiving device information which can be delivered manually and automatically parent machine child machines child machines child machines Environment Settings Paper Settings Default Settings Item Setting Description Device Information DeliveryAvailable Paper Settings Plain Recycled Color Pre punched No A5R STMTR Origi...

Page 205: ...tus Monitor Cancel On Off No Default Screen Status Monitor Cancel Default Status Type Copy Print Send Receive Store Consumables No Status Log Job Status Log No Details Print Jobs Send Jobs Receive Jobs Copy Fax Forward Local Print Printer RX Print Print Report No Copy Screen Display Settings Regular Copy Express Copy No Display Fax Function On Off No Enable Fax in Scan and Send Function On Off No ...

Page 206: ...rements Yes Change Energy Saver Mode 10 25 50 None Enerqv Saver Mode Time 5 10 15 20 30 40 50 min 1 hour 90 min 2 3 4 hours Network If you are configuring the settings for the first time in Interface Settings TCP IPv4 Settings TCP IPv6 Settings or Settings Common to TCP IPv4 and TCP IPv6 use the control panel of the machine After configuring the TCP IP settings you can change them using the Remote...

Page 207: ...gs DNS Server Address Settings IPv4 Primary DNS Server IP Address 0 0 0 0 Yes No Secondary DNS Server IP Address 0 0 0 0 Yes No IPv6 Primary DNS Server IPv6 Address Yes No Secondary DNS Server IPv6 Address Yes No DNS Host Domain Name Settings Yes No IPv4 Host Name 47 characters maximum Yes No Domain Name 47 characters maximum Yes No IPv6 Use Same Host Name Domain Name as IPv4 On Off Yes No Host Na...

Page 208: ... Yes IPP Print Settings IPP Print Settings On Off Yes Yes Use SSL On Off Yes No Use Authentication On Off Yes No User User name for IPP authentication 24 characters maximum Yes No Password Password for IPP authentication 24 characters maximum Yes No Multicast Discovery Settings Response On Off Yes Yes Scope name Scope name to be used for a multicast discovery 32 characters maximum Yes No Use HTTP ...

Page 209: ...rt Specify by Port Number Specify by Service Name Yes No IKE Settings IKE mode Main Aggressive Yes No Authentication Method Pre Shared Key Method Digital sig Method Yes No Auth Encryption Algorithm Auto Manual Settings Yes No IPSec Network Settings Validity Time 1to65535minuites 480minuites Yes No Validity Size 1to65535 MB 65535 MB Yes No PFS On Off Yes No Auth Encryption Algorithm Auto Manual Set...

Page 210: ...terval 1 to 255seconds 5seconds Yes No Printer Form 0 to 255 0 Yes No Buffer Size 3 to 20KB 20KB Yes No Service Mode Service only currently mounted form Change forms as needed Minimize form changes across print queues Minimize form changes within print queues Yes No NPrinter Settings Print ServerName 64 characters maximum Yes No Tree Name 32 characters maximum Yes No Context 256 characters maximum...

Page 211: ... User MIB Access Permission Security Settings Authent Algorithm Authent Password Encryption Algorithm Encryption Password Yes No Details Edit User MIB Access Permission Security Settings Authent Algorithm Authent Password Encryption Algorithm Encryption Password Yes No Delete Yes No Context Settings Context Name 32 characters maximum Register Context Name 32 characters maximum Yes No Edit Yes No D...

Page 212: ...e 24 characters maximum Yes No Firewall Settings IP Address Block Log Time Category IP Address Result Yes No IPv4 Address Filter Send Filter Yes No Use Filter On Off Yes No Default Policy Allow Reject Yes No IPv4 Address Up to 16 IPv4 addresses can be stored Yes No Receive Filter Use Filter On Off Yes No Default Policy Allow Reject Yes No IPv4 Address Up to 16 IPv4 addresses can be stored Yes No I...

Page 213: ...tings Standard Slightly Slow Slow No Reversed Display Color On Off No Adjustment Maintenance Adjust Image Quality Default Settings Item Setting Description Device Information Delivery Available Auto Adjust Gradation Quick Adjust Press Start Full Adjust Automatic after the machine prints and scans four sets of test pages No Correct Density Copy Scan and Store Mail Box Black Send Scan and Store othe...

Page 214: ...s Start No Original Scanning Area Cleaning Method 1 Press Done No Function Settings Common Default Settings 1Indicates items that appear only when the appropriate optional equipment is attached 2Indicates information that is delivered only if the number of output trays in the host machine and client machines is the same 3Indicates items that cannot be used with the default setting Also the Adobe L...

Page 215: ...to Black Text Priority Photo Priority Yes Local Print Default Settings Select Paper All Paper Sources Auto No No of Prints 1 to 9 999 sets 1set No Finishing No If No Finisher Is Attached Do Not Collate Collate Page Order Rotate Collate Group Same Pages Rotate Group No If the Stapele Finisher A1 Is Attached Do Not Collate Collate Page Order Offset Group Same Pages Offset Group Staple CornerTop Left...

Page 216: ...Buffer Pass Unit F1 and Document Insertion Folding Unit G1 Are Attached Do Not Collate Collate Page Order Offset Group Same Pages Offset Group Staple Corner Top Left Bottom Left Top Right Bottom Right Double Left Right Hole Punch Fold Face Up Face Down If the Staple Finisher B1 Booklet Finisher B1 Buffer Pass Unit F1 External 2 3 Hole Puncher A1 and Document Insertion Folding Unit G1 Are Attached ...

Page 217: ...2 2 Yes Auto Online On Off Yes Auto Online On Off Yes Generate File High Compression Image Quality Level Image Level in Text Photo Mode or Photo Mode Data Size Priority Normal Image Quality Priority Yes Image Level in Text Mode Data Size Priority Normal Image Quality Priority Yes OCR Text Searchable Settings Smart Scan On Off Yes Num of Char for File Name Setting 1 to 24 Yes Trace Smooth Settings ...

Page 218: ...ttings No Shortcut 3 No Settings No Shortcut 4 No Settings No Shortcut 5 No Settings No Shortcut 6 No Settings No Auto Collate On Off Yes Image Orientation Priority On Off Auto Orientation On Off Yes Select Color Settings for Copy Use Auto Color Black On Off Yes Use Full Color On Off Yes Printer Default Settings 1 Indicates items that appear only when the appropriate optional equipment is attached...

Page 219: ...lete M1 to M18 Check Content Yes Show Comment On Off Yes Display Confirmation for Favorite Settings On Off No Change Default Screen Standard Address Book One touch Favorite Settings No Change Default Settings Register Initialize No Register Options Shortcuts Shortcut 1 2 Sided No Settings No Shortcut 2 Different Size Originals No Settings No TX Report For Error Only On Off Yes Report with TX Image...

Page 220: ...ser User name for SMTP authentication 64 characters maximum No Password Password for SMTP authentication 32 characters maximum No Allow SSL POP On Off No Allow SSL SMTP Send On Off No Display Auth Screen When Send On Off No Allow SSL SMTP Receive Always SSL On Off No Maximum Data Size for Sending 0 Off 1 to 99 MB 3MB Yes Default Subject 40 characters maximum Attached Image Yes Use SMTP Authenticat...

Page 221: ...Yes Send Receive Separate On Off Yes Yes Set Line Register User Telephone No 20 digits maximum No Register Unit Name 24 characters maximum No Select Line Type Pulse Tone No Line 2 to 8 If the Super G3 FAX Board and Super G3 2nd Line Fax Board are installed Line 2 No If the Super G3 FAX Board Super G3 2nd Line Fax Board and Super G3 3rd 4th Line Fax Board are installed Line 2 Line 3 Line 4 No Selec...

Page 222: ...efault Setting 1 Indicates items that appear only when the appropriate optional equipment is attached 7 Indicates item that is not delivered as device information Item Setting Description Device Information Delivery Available Print Report TX RX User Data List Print No Fax User Data List 1 Print No Common Settings Print on Both Side On Off Yes Select Drawer SwitchA On Off Yes SwitchB On Off Yes Swi...

Page 223: ...nd Notice for RX Errors On Off Yes Fax Settings 1 ECM RX On Off Yes Fax RX Report For Error Only On Off Yes Confidential Fax Inbox RX Report On Off Yes Receive Start Speed 33600 bps 14400 bps 9600 bps 7200 bps 4800 bps 2400 bps Yes Receive Password 20 digits maximum No Store Access Files Default Setting Item Setting Description Device Information Delivery Available Common Settings Scan and Store S...

Page 224: ...f Yes File Formats Allowed for Storing Printable Formats Only Common Office Formats All Yes Network Settings Network Place Settings Register Details Delete Yes Protocol for External Reference SMB On Off Yes WebDAB On Off Yes Encrypted Secure Print Default Setting 1 Indicates items that appear only when the appropriate optional equipment is attached Item Setting Description Device Information Deliv...

Page 225: ...ess Book Open Make Remote Address Book Open On Off Yes Management Settings User Management Default Settings 1 Indicates items that appear only when the appropriate optional equipment is attached Item Setting Description Device Information Delivery Available System Manager Information Settings System Manager ID Seven digit number maximum Yes System PIN Seven digit number maximum Yes System Manager ...

Page 226: ...twork Settings Include Exclude Dept ID On Off Address Book On Off Printer Settings On Off Paper Information On Off Manual Delivery Settings Registration Value On Off Network Settings Include Exclude Dept ID On Off Address Book On Off Printer Settings On Off Paper Information On Off Restrictions for Receiving Device Info On Off Restore Data Settings Registration Value Dept ID Address Book Printer S...

Page 227: ...enerate Key Generate Update Device Signature Key No Certificate Settings Key and Certificate List Key and Certificate List for this Machine Editing Key Pairs and Server Certificates Confirming a Key Pair and Device Certificate Certificate Details Version Serial Number Signature Algorithm Issue Destination Start Date of Validity End Date of Validity Issuer Public Key Cert Thumbprint Certificate No ...

Page 228: ...Print No Use SSL On Off No On Use SSL On Off No Remote UI On Off Yes Use SSL On Off No On Use SSL On Off No Use Reference Print On Off Yes Delete Message Board Contents Clear No Data Management Default Settings 1 Indicates items that appear only when the appropriate optional equipment is attached Item Setting Description Device Information Delivery Available HDD Data Complete Deletion Timing of De...

Page 229: ...5 5 Service Mode Overview COPIER FEEDER SORTER BOARD Soft Counter List Test Print ...

Page 230: ...e DC controller PCB or executed the RAM clear function adjustment values for ADJUST or OPTION return to default Therefore when you made adjustments and changed values of the Service Mode in the field be sure to write down the changed values in the service label When there is no relevant field in the service label write down the values in a blank field Service Label F 5 1 ...

Page 231: ...troller PCB ROM ver Lv 1 Details To display the ROM ver of Option Controller PCB Use case When upgrading the firmware Display adj set range 00 01 to 99 99 MN CONT Display of MNCON firmware version Lv 1 Details To display the firmware version of Main Controller PCB Use case When upgrading the firmware Display adj set range 00 01 to 99 99 RUI Display of remote UI version Lv 1 Details To display the ...

Page 232: ...y the version of Russian language file Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION LANG SL Display of Slovenian language file ver Lv 2 Details To display the version of Slovenian language file Use case When upgrading the firmware Display adj set range 00 01 to 99 99 LANG SV Display of Swedish language file version Lv 2 Details To display the ver...

Page 233: ...ctionary is displayed when no file is found Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION TTS FR Dis of French voice dictionary version Lv 1 Details To display the version of French voice dictionary is displayed when no file is found Use case When upgrading the firmware Display adj set range 00 01 to 99 99 TTS ES Dis of Spanish voice dictionary ve...

Page 234: ...mware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION MEDIA TK Dis of Turkish media information version Lv 2 Details To display the version of Turkish media information Use case When upgrading the firmware Display adj set range 00 01 to 99 99 MEDIA CS Dis of Czech media information version Lv 2 Details To display the version of Czech media information Use case When upgrading the firmwa...

Page 235: ... when the 1 path DADF is connected is displayed when the 1 path DADF is not connected Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION FAX1 Display of 1 line FAX PCB ROM version Lv 1 Details To display the ROM version of 1 line FAX PCB NULL is displayed if the PCB is not connected Use case When upgrading the firmware Display adj set range ASCII chara...

Page 236: ...ing the firmware Display adj set range 00 01 to 99 99 MOBPR AP Display of mobile print JAVA UI version Lv 1 Details To display the version of the mobile print application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION RPTL AP Display of RUI portal version Lv 1 Details To display the RUI portal version Use case When upgrading the firmware Di...

Page 237: ...application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION COPY PL Dis of COPY appli Polish file version Lv 2 Details To display the Polish language file version of COPY application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPY PT Dis of COPY appli Portuguese file ver Lv 2 Details To display the Port...

Page 238: ...ile version of SEND application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION SEND KO Dis of SEND appli Korean file version Lv 2 Details To display the Korean language file version of SEND application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 SEND CS Dis of SEND appli Czech file version Lv 2 Details ...

Page 239: ... adj set range 00 01 to 99 99 COPIER DISPLAY VERSION SEND SK Dis of SEND appli Slovak file version Lv 2 Details To display the Slovak language file version of SEND application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 SEND TK Dis of SEND appli Turkish file version Lv 2 Details To display the Turkish language file version of SEND application JAVA UI Use case ...

Page 240: ...ul Features application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION INTRO PL Dis of useful func intro Polish file ver Lv 2 Details To display the version of Polish language file of Introduction to Useful Features application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 INTRO PT Dis useful func intro Portuguese fileve...

Page 241: ... version of traditional Chinese language file for custom menu application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION CSTMN KO Dis of custom menu Korean file version Lv 2 Details To display the version of Korean language file for custom menu application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 CSTMN CS Dis of cus...

Page 242: ...m menu application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION CSTMN SK Dis of custom menu Slovak file version Lv 2 Details To display the version of Slovak language file for custom menu application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 CSTMN TK Dis of custom menu Turkish file version Lv 2 Details To display t...

Page 243: ...ccessibility application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION ACSBT PL Dis of accessibility Polish file version Lv 2 Details To display the version of Polish language file for Accessibility application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 ACSBT PT Dis of accessibility Portuguese file ver Lv 2 Details T...

Page 244: ...display the version of Korean language file for ERS application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION ERS CS Display of ERS Czech file version Lv 2 Details To display the version of Czech language file for ERS application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 ERS DA Display of ERS Danish file version Lv ...

Page 245: ...o display the version of Catalan language file for ERS application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION UAC FR Display of UAC French file version Lv 1 Details To display the version of French language file for UAC application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 Supplement memo UAC User Access Control ...

Page 246: ...ading the firmware Display adj set range 00 01 to 99 99 Supplement memo UAC User Access Control COPIER DISPLAY VERSION UAC PT Display of UAC Portuguese file ver Lv 2 Details To display the version of Portuguese language file for UAC application Use case When upgrading the firmware Display adj set range 00 01 to 99 99 Supplement memo UAC User Access Control UAC RU Display of UAC Russian file versio...

Page 247: ...PROM version 1 digit hexadecimal notation COPIER DISPLAY VERSION ROM K Display of Bk clr Laser Scanner version Lv 2 Details To display the lot No unit version and EEPROM version written in EEPROM of Laser Scanner Unit Bk Use case When checking the lot No or EEPROM version of Laser Scanner Unit Adj set operate method N A display only Display adj set range Lot No 4 digits decimal notation unit versi...

Page 248: ...e file for BOX application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION BOX ET Dis of BOX appli Estonian file version Lv 2 Details To display the version of Estonian language file for BOX application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 BOX FI Dis of BOX appli Finnish file version Lv 2 Details ...

Page 249: ...old application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION HOLD FR Dis of job hold French file version Lv 1 Details To display the French language file version of job hold application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 HOLD IT Dis of job hold Italian file version Lv 1 Details To display the...

Page 250: ...ld application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 COPIER DISPLAY VERSION HOLD SL Dis of job hold Slovenian file version Lv 2 Details To display the Slovenian language file version of job hold application JAVA UI Use case When upgrading the firmware Display adj set range 00 01 to 99 99 HOLD SV Dis of job hold Swedish file version Lv 2 Details To displa...

Page 251: ...5 23 5 ...

Page 252: ...5 5 24 ...

Page 253: ...5 25 5 ...

Page 254: ...5 5 26 ...

Page 255: ...5 27 5 ...

Page 256: ...5 5 28 ...

Page 257: ...5 29 5 ...

Page 258: ...5 5 30 ...

Page 259: ...5 31 5 ...

Page 260: ...5 5 32 ...

Page 261: ...5 33 5 ...

Page 262: ...5 5 34 ...

Page 263: ...5 35 5 ...

Page 264: ...5 5 36 ...

Page 265: ...5 37 5 ...

Page 266: ...5 5 38 ...

Page 267: ...5 39 5 ...

Page 268: ...5 5 40 ...

Page 269: ...5 41 5 ...

Page 270: ...5 5 42 ...

Page 271: ...5 43 5 ...

Page 272: ...5 5 44 ...

Page 273: ...5 45 5 ...

Page 274: ...5 5 46 ...

Page 275: ...5 47 5 ...

Page 276: ...5 5 48 ...

Page 277: ...5 49 5 ...

Page 278: ...5 5 50 ...

Page 279: ...5 51 5 ...

Page 280: ...5 5 52 ...

Page 281: ...5 53 5 ...

Page 282: ...5 5 54 ...

Page 283: ...5 55 5 ...

Page 284: ...5 5 56 ...

Page 285: ...5 57 5 ...

Page 286: ...he connecting state of Finisher related options Use case When checking the connection of Finisher related options Display adj set range Left column connecting state of Finisher related options 1 to 5 1 Without Saddle 2 With Saddle without Folding Unit 3 With Saddle and Inserter without Folding Unit 4 With Saddle and Folding Unit without Inserter 5 With Saddle Inserter and Folding Unit Right column...

Page 287: ...isplay the model name of HDD Use case When checking the model name of HDD used on the machine PCI1 Display of PCI1 connected PCB name Lv 1 Details To display the name of the PCB that is connected to PCI1 Use case When checking the name of the PCB that is connected to PCI1 Display adj set range No PCB connected Voice Board Voice PCB 3DES Board Encryption PCB 1Gbit Board Giga Ethernet PCB PCI2 Displ...

Page 288: ...e When checking the edge temperature of the Fixing Belt Display adj set range 0 to 999 Unit Deg C COPIER DISPLAY ANALOG FIX LC Dis of Pressure Belt center temperature Lv 1 Details To display the center temperature of the Pressure Belt detected by the Pressure Main Thermistor Use case When checking the temperature at the center of the Pressure Belt Unit Deg C Appropriate target value At standby 90 ...

Page 289: ...R DISPLAY ANALOG MDK HUM Dis of POD Deck compartment humidity Lv 1 Details To display the compartment humidity of the Multi Deck It may be out of order if the indicated humidity is greatly different from the machine right after power on Display adj set range 0 to 100 Unit Related service mode COPIER DISPLAY ANALOG HUM MDK TEMP DEVTEMP1 Dis of Y M Developing Ass y temperature Lv 2 Details To displa...

Page 290: ...range 0 to 900 Unit uA COPIER DISPLAY HV STS 1ATVC K4 Dis pry trns ppr intvl crrnt Bk clr Lv 2 Details To display the decuple value of the paper interval current lastly flown on the Bk Primary Transfer Roller by the primary transfer paper interval ATVC control At full color jobs Use case When estimating the life of Primary Transfer Roller based on the displayed value Display adj set range 0 to 900...

Page 291: ...lated service mode COPIER ADJUST HV TR 2TR TGT1 to 8 TR PPR1 to 8 COPIER DISPLAY HV STS 2ATVC F2 Sec Trns ATVC target current clr 1 2 SPD Lv 2 Details To display the decuple value of the target current At full color 1 2 speed derived from the latest secondary transfer Full ATVC control Use case When judging whether the secondary transfer is appropriately set At image failure Caution The correct va...

Page 292: ...arge current ctrl sampling point Y Lv 2 Details To display the AC current value flown on the Y Charging Roller when the certain voltage is Applied by the latest discharge current control AC current current to be Applied At 1 1 speed is derived from 6 sampling results Use case When checking the sampling results of discharge current control Display adj set range 0 to 5000 Unit 1 uA Appropriate targe...

Page 293: ...6 COPIER DISPLAY CCD GAIN OR Gain level of Img Sensor odd bit R frt Lv 2 Details To display the Red gain level adjustment value in odd numbered bit on CMOS Sensor of Scanner Unit paper front Continuous display of upper limit is considered a failure of the Scanner Unit Reader Controller PCB Use case When replacing the Reader Controller PCB At scanned image failure Display adj set range 0 to FFFF Ap...

Page 294: ... gain level adjustment value 1 of Scanner Unit paper front Use case When image failure occurs at front side scanning in B W mode Display adj set range 1 to 47 Appropriate target value 1 to 47 COPIER DISPLAY CCD GAIN BW2 Img Sensor gain level adj VL2 B W frt Lv 2 Details To display the CMOS Sensor B W gain level adjustment value 2 of Scanner Unit paper front Use case When image failure occurs at fr...

Page 295: ... Sensor even bit R bck Lv 2 Details To display the Red gain level adjustment value in even numbered bit on CMOS Sensor of Scanner Unit paper back Continuous display of upper limit is considered a failure of the Scanner Unit Reader Controller PCB Use case When replacing the Reader Controller PCB At scanned image failure Display adj set range 1 to 47 Appropriate target value 1 to 47 GAIN2 EG Gain le...

Page 296: ... transfer Full ATVC control The appropriate range may be exceeded due to wrong media setting Use case When transfer failure occurs on certain media Display adj set range 0 to 5000 Unit V Appropriate target value Depending on media COPIER DISPLAY DPOT 2TR BASE Dis of sec transfer ATVC base voltage Lv 2 Details To display the base voltage set by the latest secondary transfer Full ATVC control The ap...

Page 297: ...e case At the occurrence of an image density failure When analyzing the cause of a problem Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0 to 255 Unit V Appropriate target value 20 to 120 COPIER DISPLAY DPOT PVCONT M Dis of target patch contrast potntl M Lv 2 Details To display the target M patch contrast potential Check t...

Page 298: ...by D max PASCAL D max control against the environment table value Use case When image density is not appropriate Display adj set range 100 to 100 Unit COPIER DISPLAY DPOT D CONT Y Display of Y Drum total charging time Lv 1 Details To display the total charging time charging counter for the Drum Unit Y The counter can be reset in COPIER FUNCTION DPC DRMRSETY Use case When checking if the high volta...

Page 299: ...3 speed Use case When checking Display adj set range 0 to 1000 Unit V Appropriate target value 400 to 900 CHG DCM2 Dis of pry chg DC voltg M 1 2 1 3 SPD Lv 1 Details To display the primary charging DC voltage lastly applied to the Charging Roller M at 1 2 and 1 3 speed Use case When checking Display adj set range 0 to 1000 Unit V Appropriate target value 400 to 900 COPIER DISPLAY DPOT CHG DCC2 Dis...

Page 300: ...o 2 Related service mode COPIER DISPLAY DENS SGNL C COPIER DISPLAY DENS DENS K Dis of Bk developer density change ratio Lv 1 Details To display difference between Bk color developer density and the target value in percentage Intolerable difference will trigger E020 This may be caused by deterioration of the developer failure disconnection of the Toner Density Sensor or error in toner supply system...

Page 301: ... target value for the Toner Density Sensor Bk Display adj set range 0 to 255 Appropriate target value 80 to 210 COPIER DISPLAY DENS SGNL Y Display of Y color developer density Lv 1 Details To display the measured value of Y color developer density The density is measured with the Toner Density Sensor Y for each job The value is updated upon print operation after power on Display adj set range 0 to...

Page 302: ... DENS D K TRGT Dis of ATR ctrl Bk patch target density Lv 2 Details To display the Bk patch image target density created by ATR control Use case When analyzing the cause of a problem Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0 to 1023 Appropriate target value 200 to 800 D CRNT P Dis of ATR ctrl dark current P wave Lv 2...

Page 303: ...et range 0 to 1023 Appropriate target value 200 to 800 COPIER DISPLAY DENS DS S C H Dis of C clr patch image density history Lv 2 Details To display the latest 8 C patch image density log data This provides cause judgment basis for E020 occurrence etc Sharp change in values may indicate failure in Patch Sensor Shutter or laser whereas gradual change may indicate failure in toner supply system This...

Page 304: ...isplay adj set range 0 to 5 Appropriate target value 0 to 5 CONT M Dis Toner Density Sensor M ctrl voltg Lv 1 Details To display the density detection control voltage of the Toner Density Sensor M Use case When checking before clearing RAM data Display adj set range 0 to 255 Unit V Appropriate target value 140 to 240 Related service mode COPIER ADJUST DENS CONT M CONT Y Dis Toner Density Sensor Y ...

Page 305: ...ue is 130 1 3 A and higher and display an error E008 001 when the value is 150 1 5 A and higher Use case When investigating the drive torque at the Pressure Belt Unit replacement or error occurrence Adj set operate method N A display only Caution Press the Clear key at FX BLT L when replacing the Pressure Belt Unit For other than the replacement execute FX L CLR to reset Display adj set range 0 to...

Page 306: ... control Adj set operate method N A display only Caution When replacing the Fixing Belt Unit press the Clear key at FX BLT U to reset Display adj set range 0 to 10 0 to 10 Related service mode COPIER COUNTER DRBL 1 FX BLT U COPIER DISPLAY FIXING FX U TM1 Dis Fix Belt Uni STBY total running time Lv 2 Details To display the total value of Fixing Belt Unit s STBY equivalent running time at all proces...

Page 307: ...d Related service mode COPIER COUNTER DRBL 1 FX BLT U COPIER DISPLAY FIXING FX U TM8 Dis Fix Belt Unit running time 32mm s Lv 2 Details To display the running time of the Fixing Belt Unit at process speed of 32 mm sec Use case When checking the use history at the Fixing Belt Unit replacement or error occurrence Adj set operate method N A display only Caution When replacing the Fixing Belt Unit pre...

Page 308: ...of 107 mm sec Use case When checking the use history at the Pressure Belt Unit replacement or error occurrence Adj set operate method N A display only Caution When replacing the Pressure Belt Unit press the Clear key at FX BLT L to reset Display adj set range 0 to 4294967295 Unit Second Related service mode COPIER COUNTER DRBL 1 FX BLT L FX L TM7 Dis Press Belt Unit running time 93mm s Lv 2 Detail...

Page 309: ...Quality Support Division Display adj set range 00 to FF Unit Hex hexadecimal Appropriate target value 50 to FF LPOWER M Display of laser light intensity M Lv 2 Details To display the M laser intensity in real time Use case When analyzing the cause of the image density failure Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0...

Page 310: ...opriate target value 0 to 700 Default value 255 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C TGT A K Dis of ARCDAT screen A Bk clr target VL Lv 2 Details To display the Bk patch target value of screen A in ARCDAT control When hue variation occurs and the displayed value is not in the tolerable range execute the auto gradation adjustment reset the target value Check the Pa...

Page 311: ...te target value 0 to 700 Default value 255 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C TGT C M Dis of ARCDAT screen C M color target VL Lv 2 Details To display the M patch target value of screen C in ARCDAT control When hue variation occurs and the displayed value is not in the tolerable range execute the auto gradation adjustment reset the target value Check the Pa...

Page 312: ...on Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C SUM A K Dis ARCDAT screen A Bk color ctrl differ Lv 2 Details To display Bk patch control difference of screen A in ARCDAT control When hue variation occurs and the displayed value is not in the tolerable range execute the auto gradation adjustment reset target value Check t...

Page 313: ...adj set range 1023 to 1023 Default value 0 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C SUM C M Dis ARCDAT screen C M color ctrl differ Lv 2 Details To display M patch control difference of screen C in ARCDAT control When hue variation occurs and the displayed value is not in the tolerable range execute the auto gradation adjustment reset target value Check the Patch...

Page 314: ...ivision Display adj set range 0 to 1023 Default value 0 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C SGNL B Y Dis ARCDAT screen B Y patch current VL Lv 2 Details To display the current Y patch value of screen B in ARCDAT control When hue variation occurs or the value shown is not in the tolerable range check the Patch Sensor or replace the developer Use case When hue vari...

Page 315: ...in accordance with the instructions from the Quality Support Division Display adj set range 0 to 1023 Default value 0 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C DLTA A Y Dis of ARCDAT screen A Y density differ Lv 2 Details To display the difference between the Y patch target value and the current value of screen A in ARCDAT control When hue variation occurs and the...

Page 316: ... Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen B Low screen ruling screen COPIER DISPLAY HT C DLTA B C Dis of ARCDAT screen B C density differ Lv 2 Details To display the difference between the C patch target value and the current value of screen B in ARCDAT control When hue variation occurs and the value shown is not in the tolerable range execute auto gradation adjust...

Page 317: ...ssing screen COPIER DISPLAY HT C TGT A Y2 ARCDAT scrn A Y clr target VL 1 2 SPD Lv 2 Details To display the Y patch target value of screen A in ARCDAT control at 1 2 speed Use case When checking ARCDAT control operation Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0 to 1023 Appropriate target value 0 to 700 Supplement mem...

Page 318: ...j set range 0 to 1023 Appropriate target value 0 to 700 Supplement memo Screen B Low screen ruling screen COPIER DISPLAY HT C TGT B C3 ARCDAT scrn B C color target VL 1 3 SPD Lv 2 Details To display the C patch target value of screen B in ARCDAT control at 1 3 speed Use case When checking ARCDAT control operation Caution Take necessary action in accordance with the instructions from the Quality Su...

Page 319: ...een C in ARCDAT control at 1 2 speed Use case When checking ARCDAT control operation Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0 to 1023 Appropriate target value 0 to 700 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C TGT C Y3 ARCDAT scrn C Y color target VL 1 3 SPD Lv 2 Details To display ...

Page 320: ...on Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C SUM A K2 ARCDAT scrnA Bk clr ctrl differ 1 2 SPD Lv 2 Details To display Bk patch control difference of screen A in ARCDAT control at 1 2 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gradation adjustment reset the target valu...

Page 321: ...adj set range 1023 to 1023 Default value 0 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C SUM C M2 ARCDAT scrn C M clr ctrl differ 1 2 SPD Lv 2 Details To display M patch control difference of screen C in ARCDAT control at 1 2 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gradation adjustment reset the target value Check...

Page 322: ...on Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C DLT A K2 ARCDAT scrn A Bk density differ 1 2 SPD Lv 2 Details To display the difference between Bk patch target value and the current value of screen A in ARCDAT control at 1 2 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gra...

Page 323: ...adj set range 1023 to 1023 Default value 0 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C DLT C M2 ARCDAT scrn C M density differ 1 2 SPD Lv 2 Details To display the difference between M patch target value and the current value of screen C in ARCDAT control at 1 2 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gradation a...

Page 324: ...ivision Display adj set range 0 to 1023 Default value 0 Supplement memo Screen A High screen ruling screen COPIER DISPLAY HT C SGL B Y2 ARCDAT scrnB Y patch current VL 1 2 SPD Lv 2 Details To display the current Y patch value of screen B in ARCDAT control at 1 2 speed When hue variation occurs and the value shown is not in the tolerable range check the Patch Sensor or replace the developer Use cas...

Page 325: ... replace the developer Use case When hue variation occurs Caution Take necessary action in accordance with the instructions from the Quality Support Division Display adj set range 0 to 1023 Default value 0 Supplement memo Screen C Copier image processing screen COPIER DISPLAY HT C SUM A Y3 ARCDAT scrnA Y clr ctrl differ 1 3 SPD Lv 2 Details To display Y patch control difference of screen A in ARCD...

Page 326: ... Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen B Low screen ruling screen COPIER DISPLAY HT C SUM B C3 ARCDAT scrnB C clr ctrl differ 1 3 SPD Lv 2 Details To display C patch control difference of screen B in ARCDAT control at 1 3 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gradation adjustment reset target value If not ...

Page 327: ...t memo Screen C Copier image processing screen COPIER DISPLAY HT C DLT A Y3 ARCDAT scrn A Y density differ 1 3 SPD Lv 2 Details To display the difference between the Y patch target value and the current value of screen A in ARCDAT control at 1 3 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gradation adjustment reset target value If not corrected ch...

Page 328: ...n Display adj set range 1023 to 1023 Default value 0 Supplement memo Screen B Low screen ruling screen COPIER DISPLAY HT C DLT B C3 ARCDAT scrn B C density differ 1 3 SPD Lv 2 Details To display the difference between the C patch target value and the current value of screen B in ARCDAT control at 1 3 speed When hue variation occurs and the value shown is not in the tolerable range execute auto gra...

Page 329: ... Screen C Copier image processing screen COPIER DISPLAY HT C SGL A Y3 ARCDAT scrnA Y patch current VL 1 3 SPD Lv 2 Details To display the current Y patch value of screen A in ARCDAT control at 1 3 speed When hue variation occurs and the value shown is not in the tolerable range check Patch Sensor or replace the developer Use case When hue variation occurs Caution Take necessary action in accordanc...

Page 330: ...adj set range 0 to 1023 Default value 0 Supplement memo Screen B Low screen ruling screen COPIER DISPLAY HT C SGL C Y3 ARCDAT scrnC Y patch current VL 1 3 SPD Lv 2 Details To display the current Y patch value of screen C in ARCDAT control at 1 3 speed When hue variation occurs and the value shown is not in the tolerable range check Patch Sensor or replace the developer Use case When hue variation ...

Page 331: ...5 103 5 ...

Page 332: ...5 5 104 ...

Page 333: ...5 105 5 ...

Page 334: ...5 5 106 ...

Page 335: ...5 107 5 ...

Page 336: ...5 5 108 ...

Page 337: ...5 109 5 ...

Page 338: ...5 5 110 ...

Page 339: ...5 111 5 ...

Page 340: ...5 5 112 ...

Page 341: ...5 113 5 ...

Page 342: ...5 5 114 ...

Page 343: ...5 115 5 ...

Page 344: ...5 5 116 ...

Page 345: ...5 117 5 ...

Page 346: ...5 5 118 ...

Page 347: ...5 119 5 ...

Page 348: ...5 5 120 ...

Page 349: ...5 121 5 ...

Page 350: ...5 5 122 ...

Page 351: ...5 123 5 ...

Page 352: ...5 5 124 ...

Page 353: ...5 125 5 ...

Page 354: ...5 5 126 ...

Page 355: ...5 127 5 ...

Page 356: ...5 5 128 ...

Page 357: ...5 129 5 ...

Page 358: ...5 5 130 ...

Page 359: ...5 131 5 ...

Page 360: ...5 5 132 ...

Page 361: ...5 133 5 ...

Page 362: ...5 5 134 ...

Page 363: ...5 135 5 ...

Page 364: ...5 5 136 ...

Page 365: ...5 137 5 ...

Page 366: ...5 5 138 ...

Page 367: ...5 139 5 ...

Page 368: ...e 6 For R D use 7 For R D use P003 0 For R D use 1 For R D use 2 For R D use 3 For R D use 4 For R D use 5 For R D use 6 For R D use 7 For R D use P004 0 For R D use 1 For R D use 2 For R D use 3 Not used 4 Not used 5 For R D use 6 For R D use 7 For R D use Address bit Name Symbol Remarks P005 0 For R D use 1 For R D use 2 For R D use 3 For R D use 4 For R D use 5 For R D use 6 For R D use 7 For R...

Page 369: ... 1 Drive current C 14 Pre fixing Feed Motor Current Switch 0 M35 13 Fixing Belt Displacement Control Motor Current Switch 1 M46 I1 I0 0 0 HOLD_OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current C 12 Fixing Belt Displacement Control Motor Current Switch 0 M46 11 Fixing Pressure Release Motor Current Switch 1 M47 I1 I0 0 0 HOLD_OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current...

Page 370: ...1 Secondary transfer constant current OFF 3 Secondary Transfer Static Elimination High Voltage ON 0 Secondary transfer static elimination high voltage ON 1 Secondary transfer static elimination high voltage FF 2 Fixing Motor Brake M48 1 ON 0 OFF 1 Fixing Motor Speed Switch M48 0 300 to 1200rpm 1 1600 to 2400rpm 0 Reserve Address bit Name Symbol Remarks P010 15 Fixing Motor ON OFF Control M48 0 ON ...

Page 371: ...tep 1 Fixing Belt Position Sensor 2 PS72 PS71 PS72 1 1 Belt position 3 5 rear or 3 5 front error 0 1 Belt position 1 0 1 step 0 0 Center 1 0 Belt position 1 0 1 step 0 Reserve Address bit Name Symbol Remarks P012 15 Fixing Pressure Release Sensor PS73 1 Pressure release 14 Fixing Pressure Release Sensor PS73 1 Pressure release 13 Fixing Wrapping Sensor PS74 1 Paper presence 12 Fixing Inner Deliver...

Page 372: ...15 15 Reverse Sensor PS32 1 Paper presence 14 Reverse Vertical Path Sensor 1 PS33 1 Paper presence 13 Reverse Vertical Path Sensor 2 PS34 1 Paper presence 12 Reverse Vertical Path Sensor 3 PS35 1 Paper presence 11 Outer Delivery Sensor PS31 1 Paper presence 10 Left Lower Cover Sensor PS36 0 Open 1 Close 9 Multi purpose Tray Paper Sensor PS37 1 Paper presence 8 Multi purpose Tray Last Paper Sensor ...

Page 373: ...nsor PS50 0 Normal 1 Upper limit 9 Right Deck Paper Height Sensor PS52 0 Paper surface reaches to the upper limit 1 Up 8 Vertical Path Sensor 1 PS53 1 Paper presence 7 Left Deck Upper Limit Sensor PS55 0 Normal 1 Upper limit 6 Left Deck Paper Height Sensor PS57 0 Paper surface reaches to the upper limit 1 Up 5 Left Deck Pullout Sensor PS58 1 Paper presence 4 Left Deck Pickup Sensor PS54 1 Paper pr...

Page 374: ...OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current C 14 Right Deck Vertical Path Motor_I0 M40 13 Left Deck Vertical Path Motor_ I1 M41 I1 I0 0 0 HOLD_OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current C 12 Left Deck Vertical Path MotorI0 M41 11 Cassette Vertical Path Motor_ I1 M39 I1 I0 0 0 HOLD_OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current C 10 Cassette Verti...

Page 375: ...M31 I1 I0 0 0 HOLD_OFF 0 1 Drive current A 1 0 Drive current B 1 1 Drive current C 2 Secondary Transfer Roller Disengagement Motor_I0 M31 1 Pre Pre registration Multi purpose Tray Drive Motor_MD M36 1 2phase 0 1 2phase 0 Delivery Motor_MD M37 1 2phase 0 1 2phase Address bit Name Symbol Remarks P022 15 Reverse Motor_MD M38 1 2phase 0 1 2phase 14 Reserve 13 Left Deck Pickup Motor_ RESET M42 0 CLR th...

Page 376: ...tch Sensor LED ON PS21 1 ON 2 Registration Patch Shutter Solenoid SL1 1 ON 1 For R D use 0 Primary Charging C AC_CC ON Address bit Name Symbol Remarks P024 15 Primary Charging C DC ON 0 ON 14 Primary Charging C AC_CV ON 0 ON 13 Primary Charging M AC_CC ON 0 ON 12 Primary Charging M DC ON 0 ON 11 Primary Charging M AC_CV ON 0 ON 10 Primary Charging Y AC_CC ON 0 ON 9 Primary Charging Y DC ON 0 ON 8 ...

Page 377: ...tage Remote 1 Enable high voltage 0 Stop high voltage 1 Multi Deck Reset 1 Multi Deck RESET 0 Clear Multi Deck RESET 0 Multi Deck Remote ON 1 Multi Deck Remote ON 0 Multi Deck Remote OFF Address bit Name Symbol Remarks P026 15 For R D use 14 Printer Reception Signal 13 24V Pickup Remote 0 24V pickup ON 1 24V pickup OFF 12 Interruption to Controller during Spool 11 Drum Cleaning Pre exposure LED Bk...

Page 378: ...serve 2 For R D use 1 Transparency Sensor PS29 1 Paper 0 Transparency 0 Laser Interface PCB Ready Signal UN100 1 Detect After 1 is detected Clear reset Address bit Name Symbol Remarks P028 15 Multi purpose Tray Cover Sensor PS79 0 Open 14 Pressure Belt Position Sensor 1 PS76 PS76 PS77 1 1 Error 0 1 Belt position 1 0 1 step backward 0 0 Center 1 0 Belt position 1 0 1 step forward 13 Pressure Belt P...

Page 379: ...it0 DCON P030 Bit1 0 0 Full Speed 1 0 Full Speed 0 1 Half Speed 1 1 Stop Address bit Name Symbol Remarks P030 15 Primary Charging Suction Fan Full Speed FM2 DCON P030 Bit15 Bit14 0 0 Stop 0 0 Full Speed 1 0 Full Speed 0 1 Half Speed 14 Primary Charging Suction Fan Half Speed FM2 13 Primary Charging Wire Cleaning Motor IN A1 M1 DCON P030 Bit13 Bit12 0 0 Stop 1 0 CCW 0 1 CW 1 1 Brake 12 Primary Char...

Page 380: ...ose 0 Open 1 Toner Container Insertion Inlet Cover Sensor M Detection PS13 1 Close 0 Open 0 Toner Container Insertion Inlet Cover Sensor Y Detection PS10 1 Close 0 Open Address bit Name Symbol Remarks P052 15 Release Holder Shift Cam HP Sensor Y HP Detection PS11 1 HP 14 Release Holder Shift Cam HP Sensor M HP Detection PS14 1 HP 13 Release Holder Shift Cam HP Sensor C HP Detection PS17 1 HP 12 Re...

Page 381: ... Drive Motor Bk CW M7 1 ON 0 Toner Container Drive Motor Bk CCW M7 1 ON Address bit Name Symbol Remarks P054 15 Wiper Rotation Motor Y ON M11 1 ON 14 Wiper Rotation Motor M ON M14 1 ON 13 Wiper Rotation Motor C ON M17 1 ON 12 Wiper Rotation Motor Bk ON M8 1 ON 11 Primary Charging Exhaust Fan Full Speed FM3 DCON P054 Bit11 Bit10 0 0 Stop 1 0 Full Speed 0 1 Half Speed 1 1 Half Speed 10 Primary Charg...

Page 382: ...5 For R D use P004 0 7 Not used 8 9 For R D use 10 Bypass PCB Detection 0 Absence 1 Presence 11 Bypass PCB Detection 0 Absence 1 Presence 12 Main Controller PCB 2 Version bit0 13 Main Controller PCB 2 Version bit1 14 Main Controller PCB 2 Version bit2 15 Main Controller PCB Version bit3 P005 0 10 For R D use 11 SCPRDY Controller reception is available 12 Clear reset of image process chip 13 15 For...

Page 383: ...d 2 Fan Lock Signal Reserve 3 DDI SRTS 0 Reception is available 4 DDI SCPRDY 0 Controller ready 5 Silent Mode 1 Normal start up 0 Silent start up 6 Board Test 1 Normal start up 0 PCB check 7 12V Power Supply Monitor 0 Power supply P002 0 24V Power Supply Monitor 0 Power supply 1 Reader DADF Connect 1 Connect 0 Unconnected AP 2 Location Information 0 Not used 3 Location Information 1 Not used 4 Deb...

Page 384: ...e PCB2 1 Paper presence 4 Post separation 2 Sensor SR3 0 Paper presence 5 Post separation 1 Sensor SR2 0 Paper presence 6 Pickup Roller Unit Lifting HP Sensor SR12 1 HP Escape 7 Scanner Unit Cooling Fan Alarm FM3 0 Failure P003 0 Disengagement HP Sensor 2 SR16 1 HP Disengagement 1 1 path Duplex Model Identification 1 1 path duplex 0 Reverse duplex 2 Leading Edge Position Sensor SR22 1 Paper presen...

Page 385: ...rent M5 1 Operation is available 4 Delivery Motor Direction M5 1 CCW Delivery direction 5 6 7 T 5 17 Paper Deck Unit DC CON P048 to P050 Address bit Name Symbol Remarks P048 15 14 not used 13 not used 12 not used 11 not used 10 deck main motor hold M1 9 deck open solenoid SL2 0 open 1 close 8 deck lifter motor M2 0 up 1 down 7 deck lifter motor ON signal M2 0 OFF 1 ON 6 deck main motor ON signal M...

Page 386: ...18 POD Deck Lite DC CON P047 to P050 Address bit Name Symbol Remarks P047 15 Not used 14 Not used 13 Not used 12 Not used 11 Not used 10 Not used 9 Not used 8 Not used 7 Expansion Fan OFF FAN3 1 OFF 0 ON 6 Not used 5 Air Heater Control Signal H1 0 0 0 60 degC 3 1 1 90 degC 4 3 Swing Control Signal M3 0 0 0 250 pps 3 1 1 850 pps 2 1 Fan Control Signal FAN1 FAN2 FAN3 0 0 0 26V 3 1 1 13 5V 0 P048 15 ...

Page 387: ...2 1 0 bit2 0 1 Humidity DATA 1 1 bit1 1 0 bit1 0 0 Humidity DATA 0 1 bit0 1 0 bit0 0 P050 15 Large Deck ID Fix to 0 14 Deck Lifter Motor Error M2 1 Error 0 Normal 13 Deck Lite ID Fix to 0 12 Deck Lite ID Fix to 1 11 Deck Receptacle Left Open Sensor PS9 1 Close 0 Open 10 Deck Engagement Disengagement Sensor PS5 1 Open 0 Close 9 Deck Lifter Lower Limit Detection Switch SW2 1 Normal 0 Abnormal 8 Deck...

Page 388: ... heater unit READY HT101 0 Low Temperature 1 Blast temperature 1 upper deck right flotation fan ERR FAN102 0 error 0 upper deck left flotation fan ERR FAN101 0 error Address bit Name Symbol Remarks P037 15 Not use 14 Not use 13 upper deck lifter motor I1 M101 Reserve 12 upper deck lifter motor I0 M101 11 middle deck lifter motor I1 M201 Reserve 10 middle deck lifter motor I0 M201 9 lower deck lift...

Page 389: ...004 0 paper 0 delivery sensor S005 0 paper Address bit Name Symbol Remarks P041 15 middle deck right flotation fan EN FAN202 1 ON 14 middle deck left flotation fan EN FAN201 1 ON 13 air heater unit ON SEL HT201 1 5V A1T2 ON 12 air heater unit ON HT201 1 ON 11 air heater unit BIT1 HT201 1 BIT1 Select 10 air heater unit BIT0 HT201 1 BIT0 Select 9 middle deck swing motor DIR M202 1 CW 0 CCW 8 middle ...

Page 390: ...rature 1 Blast temperature 1 lower deck right flotation fan ERR FAN302 0 error 0 lower deck left flotation fan ERR FAN301 0 error Address bit Name Symbol Remarks P045 15 lower deck right flotation fan EN FAN302 1 ON 14 lower deck left flotation fan EN FAN301 1 ON 13 air heater unit ON OFF SEL HT301 1 5V A1T3 ON 12 air heater unit ON HT301 1 ON 11 air heater unit BIT1 HT301 1 BIT1 Select 10 air hea...

Page 391: ...istance Adjustment Motor 1_CW M50 1 CCW Compression distance increase 0 CW Compression distance increase 6 Decurler Compression Distance Adjustment Motor 2_CW M53 1 CCW Compression distance increase 0 CW Compression distance increase 5 Decurler Feed Motor 1_CW M51 1 CCW 0 CW CCW only 4 Decurler Feed Motor 2_CW M52 1 CCW 0 CW CW only 3 Decurler Compression Distance Adjustment Motor 1_MD M50 1 2phas...

Page 392: ... motor2CLK P31 1 P32 0 1 2phase 7 6 5 S10 4 S13 3 2 1 0 Address bit Name Symbol Remarks P040 15 14 13 Reserve solenoid SOL1 0 PWM 1 PWM 12 upper tray registration sensor S3 0 no paper 1 paper 11 lower tray registration sensor S7 0 no paper 1 paper 10 9 8 7 EEPROM IO DO signal 0 data bit 0 1 data bit 1 6 5 4 3 2 1 0 P041 15 14 13 12 11 10 EEPROM CS signal 9 EEPROM DA IO DIsignal 8 EEPROM DA IO CLK ...

Page 393: ...ta bus 1 0 pickup motor CLK M1 Address bit Name Symbol Remarks P044 15 lower tray pick sensor S6 0 outside pick position 1 pick position 14 lower tray last paper sensor2 S15 0 no paper 1 paper 13 lower tray last paper sensor1 S14 0 paper 1 no paper 12 lower tray Empty sensor S12 0 paper 1 no paper 11 upper tray lower limit sensor S4 0 outside lower limit 1 lower limit 10 upper tray pick sensor S2 ...

Page 394: ...hing Motor HP Sensor PS7 1 paper 11 Integration unit reverse path 3 sensor RS4 1 paper 10 Integration unit reverse path 2 sensor RS3 1 paper 9 Integration unit reverse path 1 sensor RS2 1 paper 8 Integration unit bypass 1 sensor RS1 1 paper 7 P puncher bypass 8 sensor S8 1 paper 6 P puncher bypass 7 sensor S7 1 paper 5 P puncher bypass 6 sensor S6 1 paper 4 P puncher bypass 5 sensor S5 1 paper 3 P...

Page 395: ... 1 paper 7 6 5 4 3 2 Fold tray branch flapper solenoid SOL4 0 PWM 1 PWM 1 Flash write Communication received 0 Flash write Communication Send Address bit Name Symbol Remarks P031 15 EEPROM IO DO signal 0 data bit0 1 data bit1 14 C fold tray motor CLK M7 13 lead edge holding guide motor CLK M10 12 Rotation direction of lead edge holding guide motor M10 0 CW 1 CCW 11 C fold stopper adjustment motor ...

Page 396: ... 15 14 13 12 11 10 9 8 7 Fold unit pull out sensor S29 0 close 1 open 6 Fold tray paper sensor S27 1 paper 5 Fold tray full sensor S26 1 paper 4 Fold tray HP sensor S28 0 HP outside 1HP input 3 Delivery 1 sensor S22 1 paper 2 2nd fold push on stopper HP sensor S23 0 HP outside 1HP input 1 C fold stopper HP sensor S24 0 HP outside 1HP input 0 Lead edge holding guide HP sensor S25 0 HP outside 1HP i...

Page 397: ...signal M110 5 Swing Guide Motor rotation signal M110 0 CW 1 CCW 4 Inlet Sensor S101 0 paper 1 no paper 3 Swing Guide Height Detection Sensor S118 1 detected 2 1 0 Feed Path Senor S102 0 no paper 1 paper P002 15 Inlet Feed Motor M200 0 CW 1 CCW 14 Inlet Feed Motor M200 13 Stack Delivery Lower Shutter Motor rotation M122 0 CW 1 CCW 12 Stack Delivery Lower Shutter Motor clock M122 11 DA converter 1 c...

Page 398: ...er 14 Tray Paper Surface Sensor 4 PBA700 0 no paper 1 paper 13 Tray Paper Surface Sensor 1 PBA700 0 no paper 1 paper 12 Tray Paper Surface Sensor 2 PBA700 0 no paper 1 paper 11 Gripper Base Rear Sensor S117 1 front 10 Gripper Base Front Sensor S116 1 rear 9 Gripper Position Sensor S115 0 front 1 rear 8 Gripper HP Sensor S140 1 home 7 EXIO2 chip select 6 5 4 Display LED2 0 ON 1 OFF 3 Display LED1 0...

Page 399: ...r CW M105 0 CW 1 CCW 8 Tray 1 Shift Motor CUR M105 0 OFF 1 ON 7 Stapler Shift HP Sensor S107 1 home 6 Escape Tray Paper Sensor S130 1 detected 5 Tray 1 Paper Sensor S104 0 no paper 1 paper 4 Tray 1 Area Sensor 1 S122 0 no paper 1 paper 3 Tray 1 Area Sensor 2 S123 0 no paper 1 paper 2 Tray 1 Area Sensor 3 S124 0 no paper 1 paper 1 Tray 1 Shift Motor M105 0 abnormal 1 normal 0 Tray 2 Shift Motor ala...

Page 400: ...Guide Motor CLK M112 0 Paper Return Guide Motor DIR M112 0 CW 1 CCW Address bit Name Symbol Remarks P013 15 Punch slide motor CW M101 0 CW 1 CCW 14 Punch slide motor CLK M101 13 12 11 10 9 8 7 Inserter connection 0 connected 6 IF connection 0 connected 5 4 Punch connection 0 connectecd 3 Punch motor CCW M102 0 CW 1 CCW 2 Punch motor CW M102 0 CCW 1 CW 1 Punch motor ON M102 0 OFF 1 ON 0 P014 15 Pow...

Page 401: ...CW 7 6 5 Push switch 0 ON 1 OFF 4 Push switch 0 ON 1 OFF 3 Dip switch 4 0 ON 1 OFF 2 Dip switch 3 0 ON 1 OFF 1 Dip switch 2 0 ON 1 OFF 0 Dip switch 1 0 ON 1 OFF Address bit Name Symbol Remarks P017 15 14 13 12 11 10 9 8 Punch slide motor standby signal 0 stanfby 1 ready 7 Punch slide motor enable signal 0 enable 1 disenable 6 5 DipSW input 2 0 ON 1 OFF 4 DipSW input 1 0 ON 1 OFF 3 2 1 0 P018 15 Sa...

Page 402: ...er 1 Saddle Paper Tapping HP Sensor S215 1 home 0 Saddle Inlet Sensor S201 1 paper Address bit Name Symbol Remarks P021 15 14 13 12 11 Saddle Stitcher Motor CCW signal M209 0 CW 1 CCW 10 Saddle Stitcher Motor CW signal M209 0 CCW 1 CW 9 Saddle Stitcher Motor ON signal M209 0 OFF 1 ON 8 Inserter lock power source detection 0 detected 24V 7 Saddle Roller Guide Motor rotation M204 1 CW 0 CCW 6 Saddle...

Page 403: ...P sensor S104 0 release position 1 feed position 14 Front estrangement motor HP sensor S102 0 feed position 1 release position 13 Paper delivery sensor 1 paper 12 11 DIPSW 1 0 ON 1 OFF 10 DIPSW 2 0 ON 1 OFF 9 DIPSW 3 0 ON 1 OFF 8 DIPSW 4 0 ON 1 OFF 7 Press motor CW CCW switching signal M105 0 release 1 touch 6 Press motor standby signal M105 0 standby 1 ready 5 Press motor output permission signal...

Page 404: ... Front estrangement motor current setting PWM output M103 11 Rear estrangement motor current setting PWM output M104 10 Press motor current setting PWM output M105 9 Front estrangement motor output permission signal M103 0 permission 1 prohibition 8 Front estrangement motor drive clock output M103 7 6 5 5V shutdown signal 1 shutdown 4 3 2 Paddle solenoid ON signal SL102 0 ON 1 OFF 1 Stopper soleno...

Page 405: ...ignal1 2 1 0 P050 7 Through pass IN_motor driver current Analog input 6 Paper feed motor driver current Analog input 5 4 3 2 1 0 P051 7 6 5 4 3 2 1 0 Address bit Name Symbol Remarks P052 7 Folding unit sensor H No unit 6 By Borah motor driver_standby signal H Movement is possible L stop 5 Reverse solenoid_PWM SL1 PWM 4 3 2 1 PCB LED2 L ON 0 PCB LED1 L ON P053 7 6 DSW5 L ON 5 DSW6 L ON 4 DSW7 L ON ...

Page 406: ... A M3 H active 5 Reserve unit motorB M3 H active 4 Reserve unit motorA M3 H active 3 Straight path feed motor IN B M9 H active 2 Straight path feed motor IN A M9 H active 1 Straight path feed motor IN B M9 H active 0 Straight path feed motor IN A M9 H active P048 7 DAconverter Cssignal 6 C fold flapper solenoid SL5 H Absorption 5 4 Fold transport motor Clock signal M5 3 Straight path feed motor IN...

Page 407: ...ustment motor A M10 H active 5 Fold position adjustment motor B M10 H active 4 Fold position adjustment motor A M10 H active 3 Reverse sensor S10 H paper on 2 C fold stopper sensor S17 H home 1 C fold tray motor sensor S19 H home 0 C fold tray empty sensor S18 L paper on Address bit Name Symbol Remarks P057 7 C fold stopper solenoid SL7 H Absorption 6 C fold guide solenoid SL6 H Absorption 5 EEPRO...

Page 408: ... 0 drive electric current 1 maintenance electric current 4 not used 3 not used 2 not used 1 not used 0 not used Address bit Name Symbol Remarks P045 7 SW602 on the punch controller PCB 0 ON 1 OFF 6 SW603 on the punch controller PCB 0 ON 1 OFF 5 for R D 4 not used 3 LED602 on the punch controller PCB 0 OFF 1 ON 2 horizontal registration motor phase B signal M62 0 phase B ON 1 phase B ON 1 horizonta...

Page 409: ...otor clock signal M101 1 punch feed motor clock signal M63 0 punch paper trailing edge detection 0 not detected 1 detected P005 7 not used 6 not used 5 tray motor clock signal 4 saddle serial signal 3 saddle serial signal 2 PWM output for solenoid 1 for R D 0 for R D Addres bit Description Symbol Remarks P006 7 not used 6 not used 5 expansion I O read signal 4 for R D 3 expansion I O write signal ...

Page 410: ...andby M63 0 standby 1 drive 3 punch feed motor electric current change I0 M63 2 punch feed motor electric current change I1 M63 1 feed motor electric current change I0 M101 0 feed motor electric current change I1 M101 Addres bit Description Symbol Remarks P014 7 tray 1 shift motor enable signal M107 0 standby 1 drive 6 tray 1 shift motor CW CCW signal M107 0 CW 1 CCW 5 tray 1 shift motor ON signal...

Page 411: ...lock signal M105 P020 7 not used 6 not used 5 not used 4 not used 3 escape feed motor phase B signal M112 2 escape feed motor phase A signal M112 1 escape feed motor phase B signal M112 0 escape feed motor phase A signal M112 Addres bit Description Symbol Remarks P021 7 puncher unit connection detection 0 connected 1 unconnected 6 tray 2 paper surface sensor 2 PI120 0 paper present 1 paper absent ...

Page 412: ... 0 besides HP 1 HP Addres bit Description Symbol Remarks P031 7 guide motor phase B signal M3 6 guide motor phase A signal M3 5 alignment motor B signal M5 4 alignment motor A signal M5 3 not used 2 paper positioning plate motor phase B signal M4 1 paper positioning plate motor phase A signal M4 0 feed motor CW CCW signal M1 0 CCW 1 CW P032 7 saddle rear staple electric current detection AD 0 OFF ...

Page 413: ...le software IPC communication 5 saddle software IPC communication 4 stitcher motor front CW signal M7 0 ON 1 OFF 3 stitcher motor front CCW signal M7 0 ON 1 OFF 2 staple sensor front SW6 0 needle absent 1 needle present 1 not used 0 not used Addres bit Description Symbol Remarks P039 7 SW504 8 on the saddle controller PCB 0 ON 1 OFF 6 SW504 7 on the saddle controller PCB 0 ON 1 OFF 5 SW504 6 on th...

Page 414: ...djust the image reading start position in horizontal scanning direction at DADF reading When replacing the Reader Controller PCB clearing RAM data enter the value of service label As the value is incremented by 1 the image position moves to the rear side by 0 1mm Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and then press OK k...

Page 415: ...Display adj set range 1 to 9999 Default value 8271 Related service mode COPIER ADJUST CCD W PLT Y W PLT Z BW TGT W PLT Y White level data Y entry of white plate Lv 1 Details When replacing the Reader Controller PCB clearing RAM data enter the value of service label When replacing the Copyboard Glass enter the value of barcode label which is affixed on the glass Use case When replacing the Reader C...

Page 416: ...UST CCD DFTAR R Shading target value R Front side Lv 1 Details When replacing the Reader Controller PCB enter the value of service label When replacing the Copyboard Glass Scanner Unit paper front execute COPIER FUNCTION CCD DF WLVL1 DF WLVL2 and write the value which is automatically set in the service label Use case When replacing the Reader Controller PCB clearing RAM data When replacing the Co...

Page 417: ... switch Display adj set range 20 to 80 Default value 50 Related service mode COPIER FUNCTION CCD MTF CLC COPIER ADJUST CCD MTF2 M6 MTF value 6 setting horz scan Front Lv 1 Details Setting value for MTF filter coefficient calculation Enter the value of service label on the Reader Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and...

Page 418: ... Reader Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 20 to 80 Default value 50 Related service mode COPIER FUNCTION CCD MTF CLC COPIER ADJUST CCD MTF2 S7 MTF value 7 setting vert scan Front Lv 1 Details Setting value for MTF filter coefficient calc...

Page 419: ...Complex chart No 10 data B Front side Lv 1 Details To derive the front back side linearity set the Blue data for paper front of No 10 image in DADF complex chart Enter the value of service label on the Reader This setting is enabled for 1 path DADF only Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and then press OK key 2 Turn ...

Page 420: ... switch Display adj set range 20 to 85 Default value 50 Related service mode COPIER FUNCTION CCD MTF CLC COPIER ADJUST CCD MTF M6 MTF value 6 setting horz scan Back Lv 1 Details Setting value for MTF filter coefficient calculation Enter the value of service label on the Reader Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and t...

Page 421: ... replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 20 to 85 Default value 50 Related service mode COPIER FUNCTION CCD MTF CLC COPIER ADJUST CCD MTF S7 MTF value 7 setting vert scan Back Lv 1 Details Setting value for MTF filter coefficient calculation Enter the value...

Page 422: ...ck side Lv 1 Details To derive the front back side linearity set the Green data for paper back of No 2 image in DADF complex chart Enter the value of service label on the Reader Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 1 to 2550 Default value 2...

Page 423: ...ower switch Display adj set range 20 to 85 Default value 50 Related service mode COPIER FUNCTION CCD MTF CLC COPIER ADJUST CCD MTF M11 MTF value 11 setting horz scan Back Lv 1 Details Setting value for MTF filter coefficient calculation Enter the value of service label on the Reader Use case When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Enter the setting value...

Page 424: ...ain power switch Display adj set range 0 to 2550 Default value 0 Related service mode COPIER ADJUST CCD DFCH R2 DFCH R10 DFCH B2 DFCH B10 DFCH G2 DFCH G10 DFCH K2 COPIER FUNCTION CCD DF LNR COPIER ADJUST CCD DFTAR BW Shading target value B W Front side Lv 1 Details When replacing the Reader Controller PCB enter the value of service label When replacing the Copyboard Glass Scanner Unit paper front ...

Page 425: ...DF WLVL4 and write the value which is automatically set in the service label Use case When replacing the Reader Controller PCB clearing RAM data When replacing the Copyboard Glass Scanner Unit paper back Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 700 to 1400 Default value 1126 Related service mode COPIER FUNCTION...

Page 426: ...al service Display adj set range 128 to 127 Unit 1 pixel Default value 0 COPIER ADJUST IMG REG REG V C Adj C color write start pstn vert scan Lv 1 Details To adjust the write start position of cyan color image in the vertical scanning direction in increments of 1 pixel Use case When cyan color displacement in the vertical scanning direction occurs Adj set operate method Enter the setting value swi...

Page 427: ...ails To adjust the standard magnification of Bk color in horizontal scanning direction Other colors are adjusted by auto registration All correction values registered in the media list are proportionally changed Use case When adjusting the standard magnification due to environmental change etc Adj set operate method Enter the setting value switch negative positive by key and press OK key Caution D...

Page 428: ...r ATR patch dens target VL Lv 1 Details To enter the C color ATR patch density target value which is set at Developing Assembly INIT After the entry write the value in the service label Use case When re entering the value at the time of DC Controller PCB replacement RAM clear Display adj set range 0 to 1023 Default value 200 to 800 COPIER ADJUST DENS SIGG K Adj of Bk color ATR patch dens target VL...

Page 429: ...uctions from the Quality Support Division Do not use the setting value 11 Display adj set range 2 to 2 2 2 0 1 1 0 0 0 1 1 0 2 2 0 Default value 0 Related service mode COPIER FUNCTION INSTALL INISET C 4 Supplement memo Toner dropping A symptom that toner drops from the Developing Unit COPIER ADJUST DENS LLMT PTY Toner Dens Sensr Y dens crrct lowr limit Lv 2 Details To adjust the lower limit of the...

Page 430: ...The offset is reset when D max control Full Adjust is executed Use case When any image failure occurs due to environment change Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution Do not use this at the normal service This is limited for the use of printer model Display adj set range 30 to 30 Default value 0 COPIER ADJUST DENS DMAX C A...

Page 431: ...dation Full Adjust COPIER ADJUST DENS P TG K Adj of Bk color ATR patch dens target VL Lv 2 Details To adjust the offset of the ATR patch target value for Bk When the target value determined upon initialization is changed the T D ratio is also changed Fogging and density increase are alleviated when the value is smaller and carrier adherence is alleviated when it is larger Use case When density fai...

Page 432: ...STALL INISET K 4 Supplement memo Toner dropping A symptom that toner drops from the Developing Unit COPIER ADJUST DENS LLMT PTK Tonr Dens Sensr Bk dens crrct lowr limit Lv 2 Details To adjust the lower limit of the target density T D ratio adjustment of the Toner Density Sensor Bk If the lower limit is smaller the density increase can be prevented in the case of high duty because QM down of develo...

Page 433: ...hen a failure occurs due to limiter of D max control Adj set operate method 1 Enter the setting value and then press OK key 2 Execute Auto Adjust Gradation Quick Adjust Caution Do not use this at the normal service Display adj set range 300 to 300 Unit 1 V Related user mode Adjustment Maintenance Adjust Image Quality Auto Adjust Gradation Quick Adjust COPIER ADJUST DENS DMLMT LC C toner charging D...

Page 434: ...n on the leading edge of paper As the value is incremented by 1 the margin is increased toward the center of the paper by 1 pixel 0 0423 mm Use case When reducing the margin upon user s request When enlarging the margin for transfer separation fixing separation Adj set operate method Enter the setting value and then press OK key Caution Do not use this at the normal service Display adj set range 0...

Page 435: ...se case When reducing the margin upon user s request When enlarging the margin for transfer separation fixing separation Adj set operate method Enter the setting value and then press OK key Display adj set range 0 to 1000 Unit 1 pixel Default value 0 T 5 35 V CONT COPIER ADJUST V CONT VCONT K Adj of Bk color contrast potential Lv 2 Details To adjust the offset of the contrast potential Vcont for B...

Page 436: ...t Adjustment Maintenance Adjust Image Quality Correct Color Cast COPIER ADJUST V CONT VBACK C Adj C color fogging removal potential Lv 2 Details To adjust the offset of the fogging removal potential Vback for C As the value is incremented by 1 the fogging removal potential changes by 10 V Reduction of fogging increase of carrier adhesion and increase of white spots at the edge Increase of fogging ...

Page 437: ... for ATR patch As the value is incremented by 1 the target contrast potential changes by 1 V Potential is increased Potential is decreased Display adj set range 40 to 50 Unit 1 V Related service mode COPIER ADJUST V CONT PT VCT M PT VCT C PT VCT K PT VCT M Adj M ATR patch target contrast potntl Lv 2 Details To adjust the M patch target contrast potential for ATR patch As the value is incremented b...

Page 438: ...10 to 10 Unit 10 V Default value 0 Required time 1 minute Related service mode COPIER ADJUST V CONT VDGAIN Y VDGAIN M COPIER ADJUST V CONT LPGAIN Y Adjustment of Y color laser power Lv 2 Details To adjust the offset of the laser power for Y As the value is incremented by 1 the laser power changes by 4 Hex Increase the gain when the density is low and decrease the gain when the density is high or a...

Page 439: ...uality Auto Adjust Gradation Full Adjust Adjustment Maintenance Adjust Image Quality Correct Color Cast COPIER ADJUST V CONT VBACK2 C Adj C fogging removal potential 1 2SPD Lv 2 Details To adjust the fogging removal potential Vback for C at 1 2 speed Fogging is alleviated but white black spots are increased due to carrier adherence White black spots are alleviated but fogging is increased Use case...

Page 440: ...ity Auto Adjust Gradation Full Adjust Adjustment Maintenance Adjust Image Quality Correct Color Cast COPIER ADJUST V CONT VBACK3 C Adj C fogging removal potential 1 3SPD Lv 2 Details To adjust the fogging removal potential Vback for C at 1 3 speed Fogging is alleviated but white black spots are increased due to carrier adherence White black spots are alleviated but fogging is increased Use case Wh...

Page 441: ... Default value According to the adjustment value of the Reader at factory shipment OFST P C C density adj at test print reading Lv 1 Details To adjust the offset of C color test print reading signal at Auto Adjust Gradation Full Adjust When replacing the Reader Controller PCB clearing RAM data enter the value of service label As the greater value is set the image after adjustment gets darker Use c...

Page 442: ... user s request Adj set operate method 1 Enter the setting value switch negative positive by key and press OK key 2 Turn OFF ON the main power switch Display adj set range 8 to 8 Default value 0 COPIER ADJUST COLOR ADJ K Bk color balance adjustment Lv 1 Details To adjust the default value of the color balance for Bk when the density of Bk varies between machines As the greater value is set the ima...

Page 443: ...olor Balance COPIER ADJUST COLOR OFST K Adj Bk bright area dens color balance Lv 1 Details To adjust the bright area density and color balance of Bk As the greater value is set the image gets darker Lower the value when the background cannot be read correctly because the density of a document is dark and increase the value when the density of a document is light Lower the value when removal of the...

Page 444: ...o 8 Default value 0 Related user mode Adjustment Maintenance Adjust Image Quality Color Balance COPIER ADJUST COLOR MD OFS M Color balance adj of M mid dens area Lv 2 Details To adjust the color balance of the intermediate density area of M As the greater value is set the image gets darker This setting is linked with Adjustment Maintenance Adjust Image Quality Color Balance Use case Do not use thi...

Page 445: ...ntenance Adjust Image Quality Color Balance COPIER ADJUST COLOR HD OFS K Color balance adj of Bk high dens area Lv 2 Details To adjust the color balance of the high density area of Bk As the greater value is set the image gets darker This setting is linked with Adjustment Maintenance Adjust Image Quality Color Balance Use case Do not use this when the machine is operating correctly Adj set operate...

Page 446: ...itive by key and press OK key 2 Turn OFF ON the main power switch Display adj set range 8 to 8 Default value 0 COPIER ADJUST COLOR PM OFS K Clr blnce adj of Bk mid dens area PDL Lv 2 Details To adjust the color balance of the intermediate density area of Bk at PDL print As the greater value is set the image gets darker Use case Do not use this when the machine is operating correctly Adj set operat...

Page 447: ...key Caution Do not use this at the normal service Display adj set range 10 to 6 Unit 1 uA Default value 0 DIS TGY Discharge current ctrl Y offset adj Lv 2 Details To adjust the offset of the target current for Y upon discharge current control for plain paper Caution Do not use this when the machine is operating correctly Display adj set range 10 to 15 Unit 5 uA Default value 0 DIS TGM Discharge cu...

Page 448: ... ADJUST HV PRI OFSTAC M OFSTAC C COPIER ADJUST HV PRI OFSTAC M Adj of M color charging AC voltage Lv 1 Details To adjust the offset of the charge AC voltage for M As the value is incremented by 1 the voltage value is increased by 20 Vpp Increase the value when the density is low and decrease the value when the density is high or a spotted image occurs Use case At the occurrence of an image density...

Page 449: ...t range 20 to 20 Unit 20 Vpp Default value 0 Related service mode COPIER ADJUST HV PRI OFSTACY2 OFSTACM2 COPIER ADJUST HV PRI OFSTACY3 Adjust Y charge AC voltage 1 3 speed Lv 1 Details To adjust the offset of the charge AC voltage for Y at 1 3 speed As the value is incremented by 1 the offset is increased by 20 Vpp Increase the value when the density is low and decrease the value when the density ...

Page 450: ... PCB clearing RAM data When an image failure occurs leopard patterns on Bk solid image Adj set operate method Enter the setting value and then press OK key Caution Do not use this at the normal service Display adj set range 30 to 40 Unit 5 uA Default value 0 2TR TGT1 Sec trns indiv set target currnt set 1 Lv 2 Details To adjust the target current of secondary transfer for setting 1 Setting 1 is th...

Page 451: ...t 2 uA Default value 0 Related service mode COPIER ADJUST HV TR TR ENV2 TR PPR2 TR CLR2 TR DUP2 2TR SHR2 COPIER ADJUST HV TR 2TR TGT3 Sec trns indiv set target currnt set 3 Lv 2 Details To adjust the target current of secondary transfer for setting 3 Setting 3 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV3 TR PPR3 TR CLR3 and TR...

Page 452: ...t 2 uA Default value 0 Related service mode COPIER ADJUST HV TR TR ENV4 TR PPR4 TR CLR4 TR DUP4 2TR SHR4 COPIER ADJUST HV TR 2TR TGT5 Sec trns indiv set target currnt set 5 Lv 2 Details To adjust the target current of secondary transfer for setting 5 Setting 5 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV5 TR PPR5 TR CLR5 and TR...

Page 453: ...t 2 uA Default value 0 Related service mode COPIER ADJUST HV TR TR ENV6 TR PPR6 TR CLR6 TR DUP6 2TR SHR6 COPIER ADJUST HV TR 2TR TGT7 Sec trns indiv set target currnt set 7 Lv 2 Details To adjust the target current of secondary transfer for setting 7 Setting 7 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV7 TR PPR7 TR CLR7 and TR...

Page 454: ...value by 1 while checking the symptom each time Display adj set range 10 to 10 Unit 100 V Default value 0 Related service mode COPIER ADJUST HV TR TR ENV1 TR PPR1 TR CLR1 TR DUP1 2TR TGT1 COPIER ADJUST HV TR 2TR SHR2 Sec trns indiv set ppr allot voltg set 2 Lv 2 Details To adjust the paper allotted voltage of secondary transfer for setting 2 Setting 2 is the combination condition of environment pa...

Page 455: ... 100 V Default value 0 Related service mode COPIER ADJUST HV TR TR ENV5 TR PPR5 TR CLR5 TR DUP5 2TR TGT5 COPIER ADJUST HV TR 2TR SHR6 Sec trns indiv set ppr allot voltg set 6 Lv 2 Details To adjust the paper allotted voltage of secondary transfer for setting 6 Setting 6 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV6 TR PPR6 TR C...

Page 456: ...NV8 TR PPR8 TR CLR8 TR DUP8 2TR TGT8 COPIER ADJUST HV TR TR PPR1 Sec trns indiv setting paper type set 1 Lv 2 Details To set the paper type paper weight for setting 1 Setting 1 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV1 TR PPR1 TR CLR1 and TR DUP1 When this condition is satisfied the target current that is set in 2TR TGT1 an...

Page 457: ...abels Default value 1 Related service mode COPIER ADJUST HV TR TR ENV2 TR CLR2 TR DUP2 2TR TGT2 2TR SHR2 COPIER ADJUST HV TR TR PPR3 Sec trns indiv setting paper type set 3 Lv 2 Details To set the paper type paper weight for setting 3 Setting 3 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV3 TR PPR3 TR CLR3 and TR DUP3 When this ...

Page 458: ...abels Default value 1 Related service mode COPIER ADJUST HV TR TR ENV4 TR CLR4 TR DUP4 2TR TGT4 2TR SHR4 COPIER ADJUST HV TR TR PPR5 Sec trns indiv setting paper type set 5 Lv 2 Details To set the paper type paper weight for setting 5 Setting 5 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV5 TR PPR5 TR CLR5 and TR DUP5 When this ...

Page 459: ...abels Default value 1 Related service mode COPIER ADJUST HV TR TR ENV6 TR CLR6 TR DUP6 2TR TGT6 2TR SHR6 COPIER ADJUST HV TR TR PPR7 Sec trns indiv setting paper type set 7 Lv 2 Details To set the paper type paper weight for setting 7 Setting 7 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV7 TR PPR7 TR CLR7 and TR DUP7 When this ...

Page 460: ...3 and less 2 Normal humidity 5 9 to 15g m3 3 High humidity 15 1g m3 and more Default value 2 Related service mode COPIER ADJUST HV TR TR PPR1 TR CLR1 TR DUP1 2TR TGT1 2TR SHR1 COPIER ADJUST HV TR TR ENV2 Sec trns indiv setting environment set 2 Lv 2 Details To set the environment absolute moisture amount for setting 2 Setting 2 is the combination condition of environment paper type paper weight co...

Page 461: ... more Default value 2 Related service mode COPIER ADJUST HV TR TR PPR5 TR CLR5 TR DUP5 2TR TGT5 2TR SHR5 COPIER ADJUST HV TR TR ENV6 Sec trns indiv setting environment set 6 Lv 2 Details To set the environment absolute moisture amount for setting 6 Setting 6 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV6 TR PPR6 TR CLR6 and TR D...

Page 462: ... then press OK key Display adj set range 1 to 2 1 B W mode 2 Color mode Default value 1 Related service mode COPIER ADJUST HV TR TR ENV1 TR PPR1 TR DUP1 2TR TGT1 2TR SHR1 COPIER ADJUST HV TR TR CLR2 Sec trns indiv setting color mode set 2 Lv 2 Details To set B W color for setting 2 Setting 2 is the combination condition of environment paper type paper weight color mode and feed side that are set i...

Page 463: ... mode Default value 1 Related service mode COPIER ADJUST HV TR TR ENV6 TR PPR6 TR DUP6 2TR TGT6 2TR SHR6 COPIER ADJUST HV TR TR CLR6 Sec trns indiv setting color mode set 6 Lv 2 Details To set B W color for setting 6 Setting 6 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV6 TR PPR6 TR CLR6 and TR DUP6 When this condition is satis...

Page 464: ...elated service mode COPIER ADJUST HV TR TR ENV1 TR PPR1 TR CLR1 2TR TGT1 2TR SHR1 COPIER ADJUST HV TR TR DUP2 Sec trns indiv setting feed side set 2 Lv 2 Details To set the feed side for setting 2 Setting 2 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV2 TR PPR2 TR CLR2 and TR DUP2 When this condition is satisfied the target curr...

Page 465: ... Lite Default value 1 Related service mode COPIER ADJUST HV TR TR ENV5 TR PPR5 TR CLR5 2TR TGT5 2TR SHR5 COPIER ADJUST HV TR TR DUP6 Sec trns indiv setting feed side set 6 Lv 2 Details To set the feed side for setting 6 Setting 6 is the combination condition of environment paper type paper weight color mode and feed side that are set in TR ENV6 TR PPR6 TR CLR6 and TR DUP6 When this condition is sa...

Page 466: ...e to the primary transfer occurs Adj set operate method 1 Enter the setting value switch negative positive by key and press OK key 2 Turn OFF ON the main power switch Display adj set range 10 to 10 Unit 0 5 uA Default value 0 COPIER ADJUST HV TR 1TR TGC Adj of prmry trns ATVC C target current Lv 2 Details To adjust the offset of the target current for C upon primary transfer ATVC control As the va...

Page 467: ... Details To adjust the offset of the target current value for Y upon primary transfer ATVC control at 1 2 speed Increase the value when spots mottled image or image failure due to insufficient transfer current occurs Decrease the value when image fogging due to transfer memory or drum memory due to strong transfer current occurs Use case When an image failure due to inappropriate primary transfer ...

Page 468: ... power switch Display adj set range 10 to 10 Default value 0 COPIER ADJUST HV TR 1TR TGC3 Adj C Pry Trns ATVC tgt crrnt 1 3 speed Lv 2 Details To adjust the offset of the target current value for C upon primary transfer ATVC control at 1 3 speed Increase the value when spots mottled image or image failure due to insufficient transfer current occurs Decrease the value when image fogging due to tran...

Page 469: ...omes smaller An image moves upward Top margin becomes larger An image moves downward When replacing the DC Controller PCB clearing RAM data enter the value of service label Use case When replacing the DC Controller PCB clearing RAM data Adj set operate method Enter the setting value switch negative positive by key and press OK key Display adj set range 50 to 50 Unit 0 1 mm Default value 0 ADJ C1 R...

Page 470: ...eds 320 mm execute mechanical adjustment Display adj set range 100 to 100 Unit 0 1 mm Default value 0 COPIER ADJUST FEED ADJ ADJ C4 Cassette 4 write start pstn in horz scan Lv 1 Details To adjust the image write start position in the horizontal scanning direction when feeding paper from the Cassette 4 paper width is within 320 mm As the value is incremented by 1 the margin on the left edge of pape...

Page 471: ...n by changing the timing to turn ON the Registration Motor when feeding heavy paper As the value is incremented by 1 the margin on the left edge of paper is increased by 0 1 mm Top margin becomes smaller An image moves upward Top margin becomes larger An image moves downward Adj set operate method Enter the setting value switch negative positive by key and press OK key Display adj set range 50 to ...

Page 472: ...istration when feeding heavy paper transparency from the Multi purpose Tray As the value is incremented by 1 the pre registration arch amount changes 0 1 mm Increase Decrease Adj set operate method Enter the setting value switch negative positive by key and press OK key Display adj set range 50 to 50 Unit 0 1 mm Default value 0 COPIER ADJUST FEED ADJ LP DUP1 Duplex pre rgst arch amount Plain Lv 1 ...

Page 473: ...s Paper Settings Paper Type Management Settings Supplement memo The paper weight B that serves as the condition for the fan to rotate at full speed is set according to the paper weight classification A of the paper used A 91 to 105g m2 B 104g m2 A 106 to 150 g m2 B 149 g m2 A 151 to 180 g m2 B 179 g m2 A 181 to 220 g m2 B 219 g m2 A 221 to 256 g m2 B 255 g m2 A 257 to 300 g m2 B 299 g m2 COPIER AD...

Page 474: ...ity mode is selected in user mode timing to turn ON at 1 2 speed is changed and the margin is adjusted Adj set operate method Enter the setting value switch negative positive by key and press OK key Display adj set range 50 to 50 Unit 0 1 mm Related user mode Function Settings Common Print Settings Coated Productivity Image Quality Priority COPIER ADJUST FEED ADJ REG MF Rgst start timing adj MP Tr...

Page 475: ... around the Secondary Transfer Outer Roller If the value is too large the arch between the pre fixing feed and fixing processes becomes too large and consequently an image failure and or jam might occur Use case When the trailing edge of thin paper or recycled paper winds around the Secondary Transfer Outer Roller and a jam occurs Adj set operate method Enter the setting value switch negative posi...

Page 476: ... 1 If the setting value is out of the range between 4 and 0 banding of other pitch might get worse After execution check magnification in the vertical scanning direction and leading edge margin and then execute auto registration Display adj set range 30 to 30 30 to 9 9 to 30 Not used Unit 0 03 Appropriate target value 0 to 4 Default value 0 Related service mode COPIER OPTION IMG TR ITB TYPE COPIER...

Page 477: ...ulti purpose Tray Paper Width Detection PCB or registering a new value execute COPIER FUNCTION CST A4 Use case When replacing the DC Controller PCB clearing RAM data When the Multi purpose Tray Paper Width Detection PCB is replaced or a new value is registered Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution After the setting value ...

Page 478: ...lue in the service label Display adj set range 0 to 255 Related service mode COPIER FUNCTION CST A5R MDK3 A4 Adj of Multi Deck Lower A4 paper width Lv 1 Details To adjust the width of A4 size paper in the Multi Deck Lower When replacing the DC Controller PCB clearing RAM data enter the value of service label When replacing the Paper Width Detection PCB or registering a new value execute COPIER FUN...

Page 479: ...ve by key and press OK key 2 Turn OFF ON the main power switch Display adj set range 2 to 2 Default value 1 COPIER ADJUST MISC ACS CNT Set jdgmt pixel count area in ACS front Lv 2 Details To set the area which counts the pixel to judge the color presence in ACS mode As the greater value is set the judgment area is widened Use case When adjusting the area which counts the pixel to judge the color p...

Page 480: ...pecified area Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 4 Default value 2 Related service mode COPIER TEST PG TYPE COPIER ADJUST MISC SEG ADJ3 Set text photo jdgmt stdrd back side Lv 1 Details To set the judgment level of text photo original in Text Photo Map mode back side at duplex reading with 1 path As ...

Page 481: ...lue is too large moire is likely to occur in an output image of COPY and SEND To match the image quality with that of the second side in the 1 path duplex stream reading mode decrease the value when moire on the first side is stronger than the second side and increase the value when it is weaker Use case When moire frequently occurs on images of COPY and SEND output Adj set operate method 1 Enter ...

Page 482: ...in power switch Caution Do not use this at the normal service Display adj set range 10 to 10 Unit 10 mA Default value 0 PR EXP M Setting of M Pre exposure LED current Lv 2 Details To set the current of the Cleaning Pre exposure LED M Increase the value when taking a measure for drum ghost Decrease the value when potential is not applied well Use case When drum ghost is significant drum pitch is no...

Page 483: ...ng a measure for drum ghost Decrease the value when potential is not applied well Use case When drum ghost is significant drum pitch is not correct When potential is not applied well Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 2 0 40 mA 1 80 mA 2 80 mA Unit 1 mA Default value 0 T 5 45 ...

Page 484: ...5 5 256 ...

Page 485: ...5 257 5 ...

Page 486: ...5 5 258 ...

Page 487: ...5 259 5 ...

Page 488: ...5 5 260 ...

Page 489: ...5 261 5 ...

Page 490: ...5 5 262 ...

Page 491: ...5 263 5 ...

Page 492: ...5 5 264 ...

Page 493: ...5 265 5 ...

Page 494: ...5 5 266 ...

Page 495: ...5 267 5 ...

Page 496: ...5 5 268 ...

Page 497: ...5 269 5 ...

Page 498: ...5 5 270 ...

Page 499: ...5 271 5 ...

Page 500: ...5 5 272 ...

Page 501: ...5 273 5 ...

Page 502: ...5 5 274 ...

Page 503: ...5 275 5 ...

Page 504: ...5 5 276 ...

Page 505: ...5 277 5 ...

Page 506: ...5 5 278 ...

Page 507: ...5 279 5 ...

Page 508: ...nstallation of the machine At occurrence of an image failure Adj set operate method Select the item and then press OK key Display adj set range During operation ACTIVE When operation finished normally OK Required time Approx 60 seconds Related service mode COPIER FUNCTION INSTALL STIR Y STIR M STIR C STIR K COPIER FUNCTION INSTALL SPLY H Y Supply of Y toner to Supply Screw Lv 1 Details Supply Y co...

Page 509: ...e Lv 1 Details To automatically execute operation necessary for initial installation of the Y Developing Assembly 1 Patch light intensity correction 2 Background correction 3 Potential control 4 Idle rotation of the Developing Assembly 5 Initialization of the Toner Density Sensor 6 Initialization of the Patch Sensor 7 Counter reset of the Developing Assembly After execution the AINR OFF setting au...

Page 510: ...C INISET K INISET 4 COPIER FUNCTION INSTALL E RDS Set use no use of Embedded RDS function Lv 1 Details To set whether to use the Embedded RDS function Use case When using Embedded RDS Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution Be sure to use E RDS RGW PORT COM TEST COM LOG and RGW ADR as a set Display adj set range 0 Function ...

Page 511: ...t range YYYYMMDDHHMM 12 digits YYYY Year MM Month DD Date HH Hour MM Minute Default value 000000000000 Supplement memo Embedded RDS Function to send device information such as the device counter failure and consumables to the sales company s server via SOAP protocol COPIER FUNCTION INSTALL CNT INTV Set counter send interval to SC server Lv 1 Details To set the interval of sending counter informati...

Page 512: ...ccessful OK is displayed If NG is displayed execute a communication test using COM TEST The setting is enabled after reboot Whether the service browser is ON or OFF can be checked in COPIER DISPLAY USER BRWS STS 1 ON 2 OFF Use case When using the service browser At operation check Adj set operate method 1 Select the item and then press OK key 2 Turn OFF ON the main power switch Caution After execu...

Page 513: ...DFTBK R DFTBK G DFTBK B DF WLVL2 White level adj in DADF mode color Lv 1 Details To adjust the white level for DADF scanning automatically by setting the paper which is usually used by the user on the DADF Use case When replacing the Copyboard Glass When replacing the Scanner Unit When replacing the Reader Controller PCB clearing RAM data Adj set operate method 1 Set paper on the DADF 2 Select the...

Page 514: ...d white shading target value Use case When replacing the Copyboard Glass Scanner Unit Caution Be sure to execute this item after execution of COPIER ADJUST CCD W PLT X W PLT Y W PLT Z Display adj set range 1 to 2047 Related service mode COPIER ADJUST CCD W PLT X W PLT Y W PLT Z T 5 47 LASER COPIER FUNCTION LASER LD ADJ Y Restore Y Skew Crrct Motor initial pstn Lv 2 Details When Y color skew volume...

Page 515: ...or all colors total charging time target Vd values for potential control and drum durability are reset Use case When replacing the Drum Units for all colors Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch When the drum replacement mode is enabled it becomes disabled automatically after execution Caution Be sure to execute this item after r...

Page 516: ...uired time Approx 2 minutes Related service mode COPIER FUNCTION DPC DRM RSET DRMRSETY DRMRSETC DRMRSETK COPIER FUNCTION DPC DRMRSETC Forcible exe of C Drum replacement mode Lv 1 Details When replacement of Drum Unit is completed within 30 minutes warm up rotation may not be executed at power off on because of high fixing temperature In such cases drum potential becomes unstable causing an image f...

Page 517: ...the Multi purpose Tray Make a fine adjustment by COPIER ADJUST CST ADJ MF A4R Adj set operate method 1 Set A4R paper on the Multi purpose Tray and set the guide so that it fits the paper width 2 Select the item and then press OK key The value is registered after automatic adjustment Caution After execution check the registered value by COPIER ADJUST CST ADJ MF A4R and write it down on the service ...

Page 518: ... service label Display adj set range 0 to 255 Related service mode COPIER ADJUST CST ADJ MDK2 A4 COPIER FUNCTION CST MDK2 A5R Reg Multi Deck Middle A5R stdrd width Lv 1 Details To register the standard value of A5R paper width 148 5 mm on the Multi Deck Middle Make a fine adjustment by COPIER ADJUST CST ADJ MDK2 A5R Adj set operate method 1 Set A5R paper on the Multi Deck Middle and set the guide ...

Page 519: ...red time Approx 10 seconds BK BNDEX Toner supply to Photosensitive Drum Lv 1 Details To form the toner band on the Photosensitive Drum and collect it with the Drum Cleaning Blade to decrease friction between the two All Photosensitive Drums and the ITB perform idle rotation and stop after toner cleaning Use case When image smear occurs due to the Drum Cleaning Blade Adj set operate method Select t...

Page 520: ...t NG Related service mode COPIER DISPLAY ANALOG FX L POS T 5 52 PANEL COPIER FUNCTION PANEL LCD CHK Check of LCD Panel dot missing Lv 1 Details To check whether there is a missing dot on the LCD Panel of the Control Panel Use case When replacing the LCD Panel Adj set operate method 1 Select the item and then press OK key 2 Check that the LCD Panel lights up in the order of white black red green an...

Page 521: ...ART CHK CL Supplement memo Remove the Inner Cover so that the Clutch can be checked visually COPIER FUNCTION PART CHK FAN Specification of operation Fan Lv 1 Details To specify the Fan to operate Use case When replacing the Fan checking the operation Adj set operate method Enter the value and then press OK key Display adj set range 1 to 23 1 Pre fixing Feed Suction Fan FM1 2 Primary Charging Sucti...

Page 522: ...While the Toner Container Drive Motor is active be sure to remove the Toner Container Otherwise toner leakage may occur in the machine Display adj set range During operation ACTIVE When operation finished normally OK Required time 1 minute Related service mode COPIER FUNCTION PART CHK MTR COPIER FUNCTION PART CHK SL Specification of operation Solenoid Lv 1 Details To specify the Solenoid to operat...

Page 523: ...and then press OK key PWD CLR Clear of system administrator password Lv 1 Details To clear the password of the system administrator set in the user mode Use case When clearing the password of the system administrator Adj set operate method Select the item and then press OK key COPIER FUNCTION CLEAR ADRS BK Clear of address book Lv 1 Details To clear the address book data Use case When clearing the...

Page 524: ...are additionally registered by the user Use case When a service person replaces discards the device Adj set operate method 1 Select the item and then press OK key 2 Check that OK is displayed 3 Turn OFF ON the main power switch Caution Unless this item is executed at the time of replacement discard of the device the CA certificate and key pair which are additionally registered by the user remain i...

Page 525: ...s OK key 2 Reboot the machine T 5 55 MISC R COPIER FUNCTION MISC R SCANLAMP Light up check of LED Lv 1 Details To light up the LED for 3 seconds Use case When replacing the LED Adj set operate method Select the item and then press OK key Display adj set range During operation ACTIVE When operation finished normally OK Required time 3 seconds 1PSCLB A DADF 2 faces color differ crrct front Lv 1 Deta...

Page 526: ... 1 Weak control 2 Strong control COPIER FUNCTION MISC R CLM PLTN Sampling of color copyboard read MTF VL Lv 1 Details The MTF value for the Reader Unit is sometimes displaced from the factory setting value depending on the condition at transportation storage If the machine is installed without correcting the value it may cause an image failure such as moire Therefore it is necessary to readjust th...

Page 527: ...TF S1 to 12 COPIER FUNCTION MISC R BWM DF2 Sampling B W back stream read MTF value Lv 1 Details The MTF value for the Reader Unit is sometimes displaced from the factory setting value depending on the condition at transportation storage If the machine is installed without correcting the value it may cause an image failure such as moire Therefore it is necessary to readjust the MTF value by reading...

Page 528: ...Related service mode COPIER FUNCTION MISC R CLM DF1 CLM TGT COPIER ADJUST CCD MTF2 M1 to 12 MTF2 S1 to 12 COPIER FUNCTION MISC R BWDF1 EN B W front stream read MTF VL initial set Lv 1 Details To return the MTF value for B W front side stream reading to the factory setting value Since overwriting is performed with the backup data retained in the Reader Controller PCB the MTF value obtained by sampl...

Page 529: ...hipment COPIER FUNCTION MISC R BWM TGT Fine adjustment of B W MTF value Lv 1 Details To perform the filter processing inside of the Reader Controller so that the MTF value measured by BWM PLTN BWM DF1 BWM DF2 becomes 55 or lower of the value When 1 is specified the MTF correction filter is calculated again and the MTF value becomes 50 or lower of the value the image becomes foggy The backed up MTF...

Page 530: ...ss OK key COPIER FUNCTION MISC P USER PRT Output of user mode list Lv 1 Details To print the user mode list Use case When printing the user mode list Adj set operate method 1 Place paper in Cassette 1 2 Select the item and then press OK key Caution Be sure to use A4 LTR size plain paper recycled paper Required time Approx 35 seconds Supplement memo It takes approximately 3 seconds before printing ...

Page 531: ...print job history all job Lv 1 Details To print the history of all print jobs stored in the machine with detailed information for maximum 5000 jobs The difference between PJH P 1 and this item is only the number of jobs printed Use case When printing the print job history with detailed information Adj set operate method 1 Place paper in Cassette 1 2 Select the item and then press OK key Caution Be...

Page 532: ...ion ACTIVE When operation finished normally OK 58 to 64 T 5 57 SYSTEM COPIER FUNCTION SYSTEM DOWNLOAD Shift to download mode Lv 1 Details To make the machine enter the download mode and wait for a command Perform downloading by SST Use case At upgrade Adj set operate method 1 Select the item and then press OK key 2 Perform downloading by SST Caution Do not turn OFF the power before HOLD is display...

Page 533: ...r troubleshooting at the time of trouble occurrence Caution During operation the setting data changes by manual or automatic adjustment When backup data which has been left for a long period of time is restored it is overwritten by the old setting data and the new data is deleted Related service mode COPIER FUNCTION SYSTEM DSRAMRES DSRAMRES Restore of DC Controller PCB SRAM Lv 2 Details To restore...

Page 534: ...5 5 306 ...

Page 535: ...5 307 5 ...

Page 536: ...5 5 308 ...

Page 537: ...5 309 5 ...

Page 538: ...5 5 310 ...

Page 539: ...5 311 5 ...

Page 540: ...5 5 312 ...

Page 541: ...5 313 5 ...

Page 542: ...5 5 314 ...

Page 543: ...5 315 5 ...

Page 544: ...5 5 316 ...

Page 545: ...5 317 5 ...

Page 546: ...5 5 318 ...

Page 547: ...5 319 5 ...

Page 548: ...5 5 320 ...

Page 549: ...5 321 5 ...

Page 550: ...5 5 322 ...

Page 551: ...5 323 5 ...

Page 552: ...5 5 324 ...

Page 553: ... selecting ON reduces productivity because the scanning area gets larger Use case When matching the scanning area with the paper size Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 OFF calculated from the detected original size 1 ON calculated from the specified paper size Default value 0 COPIER OPTION FNC S...

Page 554: ...size set in DADF mode LGL Lv 2 Details To set the size of special paper LGL configuration that cannot be recognized in DADF stream reading mode Use case Upon user s request When picking up special paper size original from DADF Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 10 0 LEGAL R 1 FOOLSCAP R 2 OFICIO R 3 ...

Page 555: ...d Default value 3 COPIER OPTION FNC SW MODELSZ2 Ppr size dtct global support in bookmode Lv 2 Details To set ON OFF for global support of document size detection in copyboard reading mode Use case Upon user s request mixed media original with AB Inch configuration Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution Do not use this at t...

Page 556: ...ress OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Following the current setting 1 Image reduction Default value 0 COPIER OPTION FNC SW REBOOTSW Restart setting at E240 error occurrence Lv 2 Details To set whether to reboot in the case of E240 error In the case of E240 error the machine is automatically rebooted due to the possibility of continuous operation of the driv...

Page 557: ... COPIER OPTION FNC SW SJOB CL Set of scan job canceling by logout Lv 1 Details To set whether to cancel the scan job in operation by logout of the user Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution The job in scanning operation cannot be canceled Display adj set range 0 to 1 0 Disabled 1 Enabled Defau...

Page 558: ...set the type of password that is required to enter when getting into service mode 2 types are available one for service technician and the other for system administrator service technician When selecting the type for system administrator service technician enter the password for service technician after the password entry by the user s system administrator Use case Upon request from the user who c...

Page 559: ...at convenience stores which do not allow PDL to be used Use case When prohibiting the use of PDL Display adj set range 0 to 1 0 Registered PDL license is enabled 1 Disabled Default value 0 COPIER OPTION FNC SW IMGCNTPR Setting of image quality mode Lv 1 Details To set the image quality mode The counter priority mode is applied when 1 is set and the image quality priority mode is applied when 0 is ...

Page 560: ... 1 0 Half speed 1 Full speed Default value 0 COPIER OPTION FNC SW OP FAN Setting of Anti adhesion Fan airflow Lv 2 Details In the normal sequence the Anti adhesion Fan is set to OFF for the reverse delivery and 1 1 speed for the straight delivery or 2 sided delivery Set the airflow of the Anti adhesion Fan when the delivery adhesion occurs or the delivery stackability decreases Set to 1 1 2 speed ...

Page 561: ...to obtain output the user expects When 0 FURUYA mode is set image is output as displayed on the screen by the new algorithm adopted from the iR ADV C Series Pseudo outline boundary for processing divided graphics separately occurred with the iR C Series does not occur However when PDL job with special data structure is sent output the user expects may not be obtained When 1 FLAG mode is set the dr...

Page 562: ...or hide the copy function Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 1 UI BOX Display hide of Inbox screen Lv 2 Details To set whether to display or hide the Inbox function Use case Upon user s request Adj set operate method 1 Enter the setting va...

Page 563: ...er mode Lv 2 Details To set whether to display or hide the Toner Container replacement screen in user mode Display adj set range 0 to 1 0 OFF 1 ON Default value 0 Required time Adjustment Maintenance Maintenance Replace Specified Toner COPIER OPTION DSPLY SW FXMSG SW ON OFF of Fixing Ass y rplce warning dis Lv 2 Details To set whether to display the warning prompting to replace the Fixing Assembly...

Page 564: ...I RSCAN Display hide of remote scan screen Lv 2 Details To set whether to display or hide the remote scan screen on the Control Panel Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 1 COPIER OPTION DSPLY SW UI EPRNT Display hide of extended print scree...

Page 565: ...y hide of mobile print Lv 2 Details To set whether to display or hide Mobile Print in the main menu Use case Upon user s request Display adj set range 0 to 1 0 Hide 1 Display Default value 1 COPIER OPTION DSPLY SW FCOT DSP ON OFF of FCOT priority mode in usermode Lv 1 Details To set whether to display Color Black Priority for First Print Time in the user mode When 1 is set the home position of the...

Page 566: ... the specifications Adj set operate method Enter the setting value and then press OK key Display adj set range 0 to 3 0 Initial value 1 Initial value 60 seconds 2 Initial value 120 seconds 3 Initial value 180 seconds Unit 60 seconds Default value 0 TMP ST1 Adjustment of standby 1 temperature Lv 1 Details To adjust the fixing start target temperature fixing recovery target temperature and standby 1...

Page 567: ... failure a separation failure wrinkles or an image failure occurs Adj set operate method Enter the setting value and then press OK key Caution When 3 or less is set a fixing failure might occur Display adj set range 9 to 2 9 45 deg C 8 40 deg C 7 35 deg C 6 30 deg C 5 25 deg C 4 20 deg C 3 15 deg C 2 10 deg C 1 5 deg C 0 0 deg C 1 5 deg C 2 10 deg C Unit 5 deg C Default value 0 COPIER OPTION IMG F...

Page 568: ...l ration temperature and print temperature 2 and 3 for Heavy 1 Set a positive value when a fixing failure occurs and set a negative value when a separation failure or wrinkles occur When an image failure occurs adjust appropriately Use 0 initial value in the normal operation Use case When a fixing failure a separation failure wrinkles or an image failure occurs Adj set operate method Enter the set...

Page 569: ...eg C 1 5 deg C 0 0 deg C 1 5 deg C 2 10 deg C Unit 5 deg C Default value 0 COPIER OPTION IMG FIX TMP H4 2 Heavy ppr4 ini rotn temp print temp 2 3 Lv 2 Details To adjust the initial rotation temperature print temperature 2 and 3 for Heavy 4 Set a positive value when a fixing failure occurs In addition use this mode when an image failure or deterioration of gloss occurs Use 0 initial value in the no...

Page 570: ...it 5 deg C Default value 0 COPIER OPTION IMG FIX TMP OHT Transp ini rotn temp print temp 1 3 Lv 2 Details To adjust the initial rotation temperature print temperature 1 to 3 for Transparency Set a positive value when a fixing failure occurs In addition use this mode when an image failure or deterioration of gloss occurs Use 0 initial value in the normal operation Use case When a fixing failure an ...

Page 571: ...ture condition to which the Pressure Belt Cooling Fan is turned OFF Adj set operate method Enter the setting value and then press OK key Display adj set range 2 to 2 2 20 deg C 1 10 deg C 0 0 deg C 1 10 deg C 2 20 deg C Unit 10 deg C Default value 0 COPIER OPTION IMG FIX NIP DWN Adj of pressure amount Coated paper Lv 2 Details To adjust the pressure amount of the Pressure Belt when feeding Coated ...

Page 572: ...et a negative value when a separation failure or wrinkles occur When an image failure occurs adjust appropriately Use 0 initial value in the normal operation Use case When a fixing failure a separation failure wrinkles or an image failure occurs Adj set operate method Enter the setting value and then press OK key Caution When 3 or less is set a fixing failure might occur Display adj set range 7 to...

Page 573: ... SW FXWRNLVL COPIER OPTION DSPLY SW FXMSG SW FXMSGSW2 COPIER OPTION IMG FIX TMP C1B Adj coated ppr 1B print fix ctrl temp Lv 2 Details To adjust the initial rotation temperature and print temperature 1 to 3 for Coated 1 which paper weight is 129 to 150g m2 default Set a negative value when wrinkles occur and set a positive value when a fixing failure occurs In addition use this mode when an image ...

Page 574: ...on speed of the Fixing Heat Exhaust Fan is switched from 40 to 70 When 1 is set the noise is alleviated by changing the timing of switching the fan rotation speed silent mode Use case Upon user s request alleviation of noise when shifting to copy mode Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 OFF 1 ON D...

Page 575: ...70 Related service mode COPIER OPTION IMG TR TR BND1 TR BND2 TRCLN2 P COPIER OPTION IMG TR TRCLN2 P Set of ITB toner supply intvl ppr intvl Lv 1 Details At paper interval the toner band formed on the ITB is removed by the ITB Cleaning Blade to decrease the friction between them This is to set the number of sheets which a toner band is formed on the ITB If the value is large the interval of toner s...

Page 576: ...G DEV DEVL PTH Set low duty toner ejectn img duty ttlVL Lv 1 Details To set the total value of the image duty which is the condition to perform the low duty toner ejection sequence When any of the average image duty of 4 colors indicates the threshold value or below low duty toner ejection sequence is executed at the paper interval calculated by dividing the total value by the value of threshold v...

Page 577: ...2 40 6 5 times 3 20 6 5 times 4 80 8 times 5 60 8 times 6 40 8 times 7 20 8 times 8 80 10 times 9 60 10 times 10 40 10 times Default value 6 COPIER OPTION IMG DEV ADJ VPP Adj of developing AC bias Vpp Lv 2 Details To adjust Vpp of the developing AC bias Ring marks and uneven sleeve pitch are alleviated when the value is decreased in the direction and white spots are alleviated when the value is in...

Page 578: ...ation adjustment is executed Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch 3 Execute the auto gradation adjustment Caution Be sure to execute auto gradation adjustment full adjustment after the setting is done Display adj set range 3 to 3 Default value 0 COPIER OPTION IMG DEV SLS TM Y Adj Y developer ejectn time continuous Lv 2 Details I...

Page 579: ...oo much To keep the proper developer amount adjust the number of supply blocks until transition to YMC color developer forcible ejection Use case When the developer increases or decreases too much due to frequent use of 1 3 speed heavy paper Adj set operate method Enter the setting value and then press OK key Display adj set range 0 to 5 Default value 0 3S SS K Adj Bk developer ejectn block 1 3 SP...

Page 580: ... case When black line occurs due to dust Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution When increasing the value too much the cleaning instruction screen may appear too often since even small dust that will not be appeared on the image can be detected When reducing the value too much black lines may appear on ...

Page 581: ...use gamma LUT at the time of image formation Use case When PASCAL related failure occurs when identifying the cause of PASCAL related failure Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 3 0 Initial LUT is used Automatic gradation adjustment is not used 1 Auto gradation adjustment is used 2 to 3 Not used Defau...

Page 582: ... with reproducibility of text Display adj set range 0 to 2 0 Text 1 Halftone photo image 2 Printed photo Default value 0 COPIER OPTION IMG MCON TNR DWN Set of toner deposit amount reduction Lv 2 Details To reduce the toner deposit amount when toner scatters or paper winds around the Fixing Assembly in the case of full color When 1 is set blur of images is decreased but the hue is changed Use case ...

Page 583: ... text is reproduced with black plain color Screen processed image Default value 0 COPIER OPTION IMG MCON IFXEML Z Set clr iFAX mail recv print img process Lv 1 Details To set the image processing which is performed when printing color iFAX or received mail Use case When there is a request for image improvement Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the...

Page 584: ...e 0 to 99 Default value 1 COPIER OPTION IMG MCON VP TXT Setting of character vectorization Lv 2 Details To make a setting of vector conversion processing for text on scalable PDF In the vector conversion processing a binary image outline is extracted in the field which is recognized as text and is converted into vector data In regular vector conversion function approximation is not used for small ...

Page 585: ...he PS Expansion Kit installed The processing is changed only for graphics and images and ERS weighting processing is performed to characters even if the setting is changed Set 1 when the aforementioned symptom occurs Set 3 if the proportion of small characters is distorted after 1 is set Set 5 if the color of graphics is not stabilized after 1 or 3 is set In this setting however a thin line of a s...

Page 586: ...d value ARCDAT control is executed by interrupting an ongoing job If the value is too large the density of image becomes different before and after the interruption If the value is too small the productivity is lowered Actual setting value is calculated by dividing the entry value by 0 9 and rounding up after the decimal points e g If an entry value is 100 setting value will be 122 Adj set operate...

Page 587: ...tch Caution Be sure to get approval from the user in advance by telling that backside is not soiled by cleaning but productivity decreases Display adj set range 0 to 2 0 OFF 1 ON 2 Not used Default value 0 T 5 67 CLEANING COPIER OPTION CLEANING W CLN P Set last rotation simple wire cln intvl Lv 2 Details To set the paper interval for automatic cleaning of the Primary Charging Wire The Primary Char...

Page 588: ...d then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 OFF 1 ON Default value 1 Related service mode COPIER OPTION CLEANING W CLN P W CLN T T 5 68 ENV SET COPIER OPTION ENV SET ENVP INT Temp humid Fix Belt temp log get cycle Lv 1 Details To set the cycle to obtain log of the humidity inside the machine and the surface temperature of the Fixing Belt As the value is i...

Page 589: ...mber of remaining papers varies according to the air floatation condition Display adj set range 0 to 5 Unit Approx 20 sheets Default value 0 Related service mode COPIER OPTION FEED SW DK5 REST DK7 REST COPIER OPTION FEED SW DK7 REST Adj paper level for Multi Deck Lower Lv 1 Details To adjust the threshold value for paper level to be determined as no paper in Multi Deck Lower When the setting value...

Page 590: ...lacement with the user Display adj set range 0 to 5 0 1000 sheets 1 200 sheets 2 600 sheets 3 800 sheets 4 2000 sheets 5 no correction Default value 0 COPIER OPTION FEED SW DK2 TURN ON OFF of Left Deck Pickup Rol last rotn Lv 1 Details To set whether to execute last rotation of the Pickup Roller on the Left Deck for 50 msec after completion of job As the usage is extended a part of the Separation ...

Page 591: ...ps the rotation As a result of that jam may occur By rotating the Pickup Roller after completion of job it can reduce wear of the Separation Roller Use case When frequency of use is relatively low When pickup jam tends to occur Display adj set range 0 to 1 0 OFF 1 ON Default value 0 Related service mode COPIER OPTION FEED SW DK1 TURN DK2 TURN DK3 TURN DK4 TURN DK5 TURN DK7 TURN COPIER OPTION FEED ...

Page 592: ... plain paper or heavy paper and ON for coated paper texture paper heavy paper 2 to 5 OHT etc When a jam or double feed error frequently occurs with plain paper etc set the value to 1 When the transfer performance is low with coated paper texture paper etc set the value to 2 Use case When a jam or double feed error frequently occurs with plain paper or heavy paper 1 When the transfer performance is...

Page 593: ...e When 1 is set papers are picked up without checking even user defined size papers that differ from the job setting size are set on the Pickup Cassette Use case When forcibly picking up papers even the paper size setting differs between a job and the Pickup Cassette Adj set operate method Enter the setting value and then press OK key Display adj set range 0 to 1 0 ON 1 OFF Default value 0 T 5 70 ...

Page 594: ...MTPTXPN Setting of SMTP TX port number Lv 2 Details To set SMTP transmission port number Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 65535 Default value 25 COPIER OPTION NETWORK SMTPRXPN Setting of SMTP reception port number Lv 2 Details To set SMTP reception port number Use case ...

Page 595: ...ed COPIER OPTION NETWORK NS NTLM Limit NTLM auth method at SMTP auth Lv 2 Details To restrict use of NTLM authentication method at the time of SMTP authentication Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 SMTP server dependent 1 Not used Default value 0 Supplement memo SMTP ...

Page 596: ... 1 for DA CNCT the following item is also ON COPIER OPTION NETWORK STS PORT CMD PORT COPIER OPTION FNC SW DA PORT Display adj set range 0 to 1 0 OFF 1 ON When installed Default value 0 Supplement memo DA Digital Accessory COPIER OPTION NETWORK DA CNCT Connection setting of WPGW Lv 2 Details To set WPGW connection Use case This mode is used for the Japanese models only and not used with overseas mo...

Page 597: ...then press OK key 2 Turn OFF ON the main power switch Caution This is active when COPIER OPTION NETWORK WUEV SW is set to 0 Notified Display adj set range 1 to 65535 Default value 11427 Related service mode COPIER OPTION NETWORK WUEV SW COPIER OPTION NETWORK WUEV RTR Setting of sleep notification range Lv 2 Details To set the number of available routers to the target for sleep notification Use cas...

Page 598: ...racter Default value 0 Supplement memo 1 Japanese Kanji character is calculated as 2 bytes and the control codes such as linefeed code etc are included in the number of characters COPIER OPTION NETWORK DNSTRANS Setting of DNS transfer priority Lv 1 Details To set priority order of the protocol IPv4 IPv6 to be used for DNS query In the case of using both IPv6 and IPv4 while the DNS server supports ...

Page 599: ...value 1 Supplement memo Network Configurator function is a function to be used for communication with NetSpot Device Installer etc and the network setting can be changed from the remote COPIER OPTION NETWORK IKEINTVL Setting of IKE retry interval Lv 1 Details To set retry interval in the case of no response from the communication target at the time of IKE packet transmission Use case Upon user s r...

Page 600: ... Disabled 2 to 5 Not used Default value 0 COPIER OPTION NETWORK PFWFTPRT Set of RST reply at IP filter FTP SEND Lv 1 Details When FTP SEND is executed using an IP filter by which packets from a specific remote PC are rejected SYN is returned to the port 113 if the PC supports authentication of the FTP port 113 However since the IP filter blocks the packets the block logs are increased and the perf...

Page 601: ...e paper smaller than B4 is determined as small size Use case As needed Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 B4 size 1 LTR size Default value 0 Related service mode COPIER OPTION USER B4 L CNT SCANTYPE Switch of ADF Reader Lv 1 Details To switch to a different type ADF Reader Unit Use case At instal...

Page 602: ...s Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution Change the setting value in accordance with the instructions from the Quality Support Division Display adj set range 00000000 to 11111111 Unit bit Default value 00000000 DEV SP6 Device special settings 6 Lv 2 Details To execute the device special settings Adj set operate method 1 En...

Page 603: ...5 375 5 ...

Page 604: ...5 5 376 ...

Page 605: ...5 377 5 ...

Page 606: ...5 5 378 ...

Page 607: ...5 379 5 ...

Page 608: ...5 5 380 ...

Page 609: ...5 381 5 ...

Page 610: ...5 5 382 ...

Page 611: ...5 383 5 ...

Page 612: ...5 5 384 ...

Page 613: ...5 385 5 ...

Page 614: ...5 5 386 ...

Page 615: ...5 387 5 ...

Page 616: ...1 Details To set counter type for software counter 3 on the Counter Check screen Use case Upon user dealer s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 999 Default value The value differs according to the location COUNTER4 Setting of software counter 4 Lv 1 Details To set counter type for software co...

Page 617: ...he main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 0 Related user mode Copy Options Supplement memo Up to 630mm length paper is supported when DADF is used COPIER OPTION USER CNT DISP Display hide of serial No Lv 2 Details To set whether to display or hide the serial No on the Counter Check screen Use case When setting to display hide serial No on the Counter Check sc...

Page 618: ...r to display Management Settings Device Management Display Log in user mode When 1 ON is set Display Log is displayed in the Device Management screen When ON is set the logs of each job are displayed in System Status When 0 OFF is set Display Log is not displayed in the Device Management screen and the logs of each job are not displayed either Display adj set range 0 to 1 0 OFF 1 ON Related user m...

Page 619: ...unter Lv 1 Details To set default display items of the charge counter on the Counter Check screen Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Caution Do not use this mode overseas outside Japan Display adj set range 0 to 1 0 Counter 1 Total 1 101 Counter 2 Total Black 1 108 Counter 3 Copy Full Color Single ...

Page 620: ... without opening closing DADF after scanning with the copyboard Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 0 COPIER OPTION USER DPT ID 7 Password entry set at dept ID reg auth Lv 2 Details To set whether to require a password entry at the time of ...

Page 621: ... for Sending Supplement memo Specify the upper limit value for transmission data size in user mode COPIER OPTION USER IFAX PGD Set page split TX at IFAX Simple mode TX Lv 2 Details To set to enable disable split data transmission on a page basis in the case that the transmission size in IFAX Simple mode exceeds the upper limit value Use case Upon user s request Adj set operate method 1 Enter the s...

Page 622: ... is available with no card inserted 1 PDL print is available only when the card ID matches the department ID when the card is inserted Default value 0 COPIER OPTION USER SLP SLCT Usage setting of network applications Lv 2 Details With the setting to use network related application the machine can be recovered through network because it does not move to sleep mode 1 For this machine to recover from...

Page 623: ...or counter at 2 color mode Lv 2 Details To set whether to use the mono color counter or full color counter for count up in 2 color mode Display adj set range 0 to 1 0 Mono color counter 1 Full color counter Default value 0 Japan 1 Others COPIER OPTION USER JA FUNC ON OFF of job archive function Lv 2 Details To set ON OFF of job archive function Caution Changing this mode is not available in servic...

Page 624: ...ER Dis hide to switch speaker headphone Lv 1 Details To set whether to display or hide Voice Guidance from Speaker on the Voice Mode Setting screen in user mode Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 0 Related user mode Settings Registration P...

Page 625: ...se Upon user s request Display adj set range 0 to 5 0 No conversion 1 Compression ratio 1 4 2 Compression ratio 1 8 3 Compression ratio 1 16 4 Compression ratio 1 32 5 Compression ratio 1 64 Default value 3 COPIER OPTION USER DK3 ASST Set of M Deck Middle Air Heater control Lv 1 Details To set the condition to turn on the Air Heater at the Multi Deck Middle in accordance with media environment Whe...

Page 626: ...y in the MEAP applications which support job archiving Use case Upon user s request Display adj set range 0 to 1 0 Packet JPEG 1 Raster JPEG Default value 0 COPIER OPTION USER HDCR DSW Dis hide of HDD complete delete ON OFF Lv 1 Details To set whether to display or hide Hard Disk Data Complete Deletion in user mode With this setting HDD data complete deletion function is available with ON OFF butt...

Page 627: ...umidity decreases Display adj set range 0 to 2 0 ON OFF depending on the media environment condition 1 ON only for the coated paper 2 Always ON No environment media dependant Default value 0 COPIER OPTION USER SNMP COA Inside comty name SNMPaccess limit admin Lv 2 Details To restrict SNMP access by the community name administrator right that is kept internally This machine internally retains the c...

Page 628: ...ory device driver Lv 2 Details To set whether to display Preferences External Interface USB Settings Use MEAP Driver for USB External Device By selecting 0 Hide the item is not displayed and the user administrator cannot change the setting of the MEAP driver for the USB external memory device Use case When prohibiting the user administrator to change the setting of Use MEAP driver for USB external...

Page 629: ...0 Hide 1 Display Default value 0 Related service mode COPIER FUNCTION CLEAR W TN CLR Related user mode Settings Registration Adjustment Maintenance Maintenance Initialize After Waste Toner Replacement COPIER OPTION USER JA SBOX Setting of linking with Advanced Box SAM Lv 2 Details To set the link with Advanced Box when iW SAM is enabled When 1 is set linking with Advanced Box is enabled Use case W...

Page 630: ... set JDF can be used Use case When the operation restriction is cleared at the time of iW SAM Display adj set range 0 to 1 0 Disabled 1 Enabled Default value 0 COPIER OPTION USER JA RUI Setting of Inbox document access SAM Lv 2 Details To set the Inbox document access from remote UI at the time of iW SAM When 1 is set accessing to the Inbox document from remote UI is enabled Use case When the oper...

Page 631: ...ecured print and inbox print are received but the normal print jobs are canceled If the password 3758211 is entered at job sending authentication by entering the password on the Control Panel is not required If the password is not entered at job sending authentication by entering the password on the Control Panel is necessary at job output In addition the following selection is added as auto delet...

Page 632: ...e setting size Display adj set range 0 to 2 0 A4 1 B5 2 LTR Default value 0 COPIER OPTION CST P SZ C2 Setting of Left Deck paper size Lv 1 Details To set the paper size used in the Left Deck Use case Upon user s request Caution Be sure to match with the hardware setting size Display adj set range 0 to 2 0 A4 1 B5 2 LTR Default value 0 D1 CURL Set of curl correct at Right Deck pickup Lv 1 Details T...

Page 633: ... 0 Related user mode Adjustment Maintenance Adjust Action Correct Curl for Each Paper Drawer COPIER OPTION CST D6 CURL Set of curl correct at MP tray pickup Lv 1 Details To set the curl correction level for the sheets picked up from the Multi purpose Tray As the value is incremented by 1 the curl correction level is increased Regardless of face up or face down increase the value in the case of upw...

Page 634: ...1 Countries other than USA 0 Related user mode Preferences Paper Settings Paper Settings A5R STMTR Original Selection COPIER OPTION CST CST4 P2 Setting of Cassette 4 paper size Lv 1 Details To set the paper size used in Cassette 4 Caution Be sure to match with the hardware setting size Display adj set range 0 to 1 0 B5 1 EXEC Default value USA 1 Countries other than USA 0 Related user mode Prefere...

Page 635: ... Details To set the overseas special paper category 3 used in Cassette 4 Display adj set range 0 to 31 0 Do not use special papers 1 to 21 Not used 22 K LGL 23 to 28 Not used 29 A LTR 30 Not used 31 G LTR Default value 0 COPIER OPTION CST CST5 U1 MDeck Upr oversea special ppr category1 Lv 1 Details To set the overseas special paper category 1 used in the Multi Deck Upper Display adj set range 0 to...

Page 636: ...nction Settings Send E Mail I Fax Settings Communication Settings SMTP Receive POP OFF Preferences Network TCP IP Settings DNS Settings FTP Print Settings Use FTP Printing OFF Preferences Network TCP IP Settings DNS Settings IPP Print Settings Use IPP Printing ON Display adj set range 0 to 7 0 No charge 1 Charge with Coin Manager 2 Charge with remote counter 3 Charge with DA only in Japan 4 Charge...

Page 637: ... ACC CC SPSW Support setting of control card I F Lv 2 Details To set support level for control card CCIV CCV interface To keep processing performance of printer engine select 1 Priority on speed To correctly stop the output by the upper limit number of sheets select 2 Priority on upper limit number of sheets Use case Upon user s request when connecting to the external counter management system usi...

Page 638: ... handled with Coin Manager Enter 8800 when specifying 8800 Japanese yen as the maximum amount to be handled with the Coin Manager that supports Japanese yen In the case to specify 1 to 4 Euro Pound Swiss Franc Dollar by going through the following COPIER OPTION ACC UNIT PRC entry is in fractional unit Entry of 50 indicates 50 cents 0 50 Use case At installation of Coin Manager Adj set operate meth...

Page 639: ...set range 0 to 5 0 Normal mode Print server not connected 1 2 Not used 3 Print server connected 4 5 Not used Default value 0 AP OPT Output set of appli with print server Lv 2 Details To set whether to permit output from the application PrintMe equipped with print server Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power ...

Page 640: ...OK key When installation has been completed the transfer license key is displayed under TR SEND Display adj set range When operation finished normally OK Default value 0 TR SEND Trns license key dis of SEND function Lv 2 Details To display transfer license key to use SEND function when transfer is disabled Use case When replacing HDD When replacing the device Adj set operate method 1 Select ST SEN...

Page 641: ... transfer license key is displayed under TR EXPDF Caution This mode is enabled when SEND function is installed for Japan Display adj set range 24 digits COPIER OPTION LCNS TR ST PDFDR Install state dis of Direct Print PDF Lv 2 Details To display installation state of Direct Print PDF when transfer is disabled Use case When checking whether Direct Print PDF is installed Adj set operate method 1 Sel...

Page 642: ...et operate method 1 Select ST BRDIM 2 Enter 0 and then press OK key The transfer license key is displayed under TR BRDIM Display adj set range 24 digits COPIER OPTION LCNS TR ST VNC Install state dis of Remote Oprtr Soft Lv 2 Details To display installation state of Remote Operators Software when transfer is disabled Use case When checking whether Remote Operators Software is installed Adj set ope...

Page 643: ...nsfer license key is displayed under TR TRSND Display adj set range 24 digits COPIER OPTION LCNS TR ST WTMRK Install state dis of Secure Watermark Lv 2 Details To display installation state of Secure Watermark when transfer is disabled Use case When checking whether Secure Watermark is installed Adj set operate method 1 Select ST WTMRK 2 Enter 0 and then press OK key When installation has been com...

Page 644: ...e transfer license key is displayed under TR DVPDF Caution This mode is enabled when SEND function is installed Display adj set range 24 digits COPIER OPTION LCNS TR ST SCPDF Install state dis of Trace Smooth PDF Lv 2 Details To display installation state of Trace Smooth PDF when transfer is disabled Use case When checking whether Trace Smooth PDF is installed Adj set operate method 1 Select ST SC...

Page 645: ...When replacing HDD When replacing the device Adj set operate method 1 Select ST PS 2 Enter 0 and then press OK key The transfer license key is displayed under TR PS Display adj set range 24 digits COPIER OPTION LCNS TR ST PCL Install state display of PCL function Lv 2 Details To display installation state of PCL function when transfer is disabled Use case When checking whether PCL function is inst...

Page 646: ...elect ST LIPS4 2 Enter 0 and then press OK key The transfer license key is displayed under TR LIPS4 Display adj set range 24 digits COPIER OPTION LCNS TR ST PSPCL Install state dis of PS PCL function Lv 2 Details To display installation state of PS PCL function when transfer is disabled Use case When checking whether PS PCL function is installed Adj set operate method 1 Select ST PSPCL 2 Enter 0 a...

Page 647: ...nd then press OK key The transfer license key is displayed under TR PSPCU Display adj set range 24 digits COPIER OPTION LCNS TR ST LXUFR Install state dis of UFR II function Lv 2 Details To display installation state of UFR II function when transfer is disabled Use case When checking whether UFR II function is installed Adj set operate method 1 Select ST LXUFR 2 Enter 0 and then press OK key When ...

Page 648: ...Select ST JBLK 2 Enter 0 and then press OK key The transfer license key is displayed under TR JBLK Display adj set range 24 digits COPIER OPTION LCNS TR ST AFAX Installation state dis of Remote Fax Lv 2 Details To display installation state of Remote Fax when transfer is disabled Use case When checking whether Remote Fax is installed Adj set operate method 1 Select ST AFAX 2 Enter 0 and then press...

Page 649: ...he transfer license key is displayed under TR XPS Display adj set range 24 digits COPIER OPTION LCNS TR ST 2600 Instal state dis IEEE2600 1 scrty func Lv 2 Details To display installation state of the IEEE2600 1 security function when transfer is disabled Use case When checking whether the IEEE2600 1 security function is installed Adj set operate method 1 Select ST 2600 2 Enter 0 and then press OK...

Page 650: ...5 5 422 ...

Page 651: ...5 423 5 ...

Page 652: ...5 5 424 ...

Page 653: ...5 425 5 ...

Page 654: ...5 5 426 ...

Page 655: ...5 427 5 ...

Page 656: ...5 5 428 ...

Page 657: ...5 429 5 ...

Page 658: ...5 5 430 ...

Page 659: ...5 431 5 ...

Page 660: ...5 5 432 ...

Page 661: ...5 433 5 ...

Page 662: ...5 5 434 ...

Page 663: ...5 435 5 ...

Page 664: ...5 5 436 ...

Page 665: ...5 437 5 ...

Page 666: ...5 5 438 ...

Page 667: ...5 439 5 ...

Page 668: ...5 5 440 ...

Page 669: ...5 441 5 ...

Page 670: ...5 5 442 ...

Page 671: ...5 443 5 ...

Page 672: ...5 5 444 ...

Page 673: ...5 445 5 ...

Page 674: ...5 5 446 ...

Page 675: ...5 447 5 ...

Page 676: ...creased the density becomes higher Use case At test print TYPE 5 Display adj set range 0 to 255 DENS M Adj of M color density at test print Lv 1 Details To adjust M color density when performing test print TYPE 5 As the value is increased the density becomes higher Use case At test print TYPE 5 Display adj set range 0 to 255 DENS C Adj of C color density at test print Lv 1 Details To adjust C colo...

Page 677: ...i Deck Lower 2 SIDE Setting of PG 2 sided mode Lv 1 Details To set 1 sided 2 sided print for PG output Use case At trouble analysis Adj set operate method Select the item and then press OK key Display adj set range 0 to 1 0 1 sided 1 2 sided Default value 0 PG QTY Setting of PG output quantity Lv 1 Details To set the number of sheets for PG output Use case At trouble analysis Display adj set range...

Page 678: ...upport Lv 2 Details To set whether to only display the device configuration in the System Monitor screen when supporting BMlinks When the setting is switched the Status and Log are not displayed Use case When supporting Bmlinks Display adj set range 0 to 1 0 Ordinary System Monitor screen 1 Screen in which only the device configuration is displayed Default value 0 IPV6 ADR Setting of PING send add...

Page 679: ...5 451 5 ...

Page 680: ...5 5 452 ...

Page 681: ...5 453 5 ...

Page 682: ...ording to the charge counter at FAX reception Large size 1 small size 1 A blank sheet is not counted Display adj set range 0 to 99999999 BOX PRT Inbox print counter Lv 1 Details To count up when the paper is delivered outside the machine according to the charge counter at Inbox print Large size 1 small size 1 A blank sheet is not counted Display adj set range 0 to 99999999 RPT PRT Report print cou...

Page 683: ...Lv 1 Details Large size 1 Small size 1 Unit Number of sheets 2 SIDE 2 sided pickup total counter Lv 1 Details Large size 1 Small size 1 Unit Number of sheets D1 POD Upper Deck pickup total counter Lv 1 Details Large size 1 Small size 1 Unit Number of sheets D2 POD Middle Deck pickup total counter Lv 1 Details Large size 1 Small size 1 Unit Number of sheets D3 POD Lower Deck pickup total counter Lv...

Page 684: ... 5 83 MISC COPIER COUNTER MISC T SPLY Y Y toner supply counter Lv 1 Details Number of Y color toner supply blocks Counted for every one rotation of Toner Stirring Screw Use case When checking the usage status of toner Unit Number of blocks T SPLY M M toner supply counter Lv 1 Details Number of M color toner supply blocks Counted for every one rotation of Toner Stirring Screw Use case When checking...

Page 685: ...se SUC L M For R D use SUC L C For R D use SUC L K For R D use T 5 84 JOB COPIER COUNTER JOB DVPAPLEN Average paper length of job Lv 1 Details Average paper length in the period from when the printer engine starts printing operation to when it stops the operation Since the printer engine considers small jobs that are executed continuously as a large job the average paper length affects calculation...

Page 686: ...ter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER PRDC 1 PO CLN Pre transfer Chg Wire Cln Pad prts cntr Lv 1 Details Pre transfer Charging Wire Cleaning Pad 1 2 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts...

Page 687: ... item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER PRDC 1 OZ FIL1 Fixing Dustproof Filter parts counter Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checki...

Page 688: ... Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 1 ITB BLD1 ITB Cleaning Blade parts counter Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level...

Page 689: ... press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 1 D UNIT M Drum Unit M parts counter Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select ...

Page 690: ... key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 1 C2 FD RL Left Deck Feed Roller parts counter Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select...

Page 691: ...d life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 1 M FD RL Multi purpose...

Page 692: ...ear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 1 PT DR M M Photosensitive Drum parts counter Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estim...

Page 693: ...ge the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 T 5 87 DRBL 2 COPIER COUNTER DRBL 2 DF PU RL Pickup Roller parts counter DADF Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of ...

Page 694: ...lect the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 COPIER COUNTER DRBL 2 PD PU RL Pickup Roller parts counter Deck Lv 1 Details Pickup Roller Front Rear of Paper Deck POD Deck Lite Multi Deck Upper 1st line Total counter value from the previous replacement 2nd line Estimated...

Page 695: ...on Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of times Default value 0 COPIER COUNTER DRBL 2 SDL STPL Saddle Stapler parts counter Fin B1 Lv 1 Details Saddle Stapler Unit 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To...

Page 696: ...he parts Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Default value 0 COPIER COUNTER DRBL 2 STK STC Stck Delv Rol Sttc Elim prts cntr Fin A1 Lv 1 Details Process delivery static elimina...

Page 697: ...unter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 ...

Page 698: ...ault value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET3 Die set 3 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select the item and press the Clea...

Page 699: ...nit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET9 Die set 9 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select the...

Page 700: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET15 Die set 15 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 701: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET21 Die set 21 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 702: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET27 Die set 27 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 703: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET33 Die set 33 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 704: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET39 Die set 39 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 705: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET45 Die set 45 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 706: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET51 Die set 51 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 707: ... Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET57 Die set 57 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Select...

Page 708: ...9999 Unit Number of sheets Default value 0 Supplement memo Product name of P Puncher Professional Puncher C1 COPIER COUNTER DRBL 2 DIESET63 Die set 63 parts counter P puncher Lv 1 Details 1st line total counter value from the previous replacement 2nd line estimated life Use case When checking the consumption level of parts or replacing the parts Adj set operate method To clear the counter value Se...

Page 709: ...evel of parts replacing the parts Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 COPIER COUNTER DRBL 2 SHT TQLM Shutter Torque Limiter prts cntr Fin ...

Page 710: ... Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 COPIER COUNTER DRBL 2 IS CL2 Lowr Tray Electmag Clt prts cntr INS H1 Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the ...

Page 711: ...eplacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 COPIER COUNTER DRBL 2 PF CL1 Pre fold Lowr Rol Drv Clt1 prts cntr PFU Lv 1 Details 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select the item and then ...

Page 712: ...er value after replacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 COPIER COUNTER DRBL 2 PD FD R2 Mid Deck Feed Roller parts cntr M Deck Lv 1 Details Middle Deck Pickup Feed Roller 1st line Total counter value from the previous replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To cl...

Page 713: ...evious replacement 2nd line Estimated life Use case When checking the consumption level of parts replacing the parts Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of times De...

Page 714: ...r the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution Clear the counter value after replacement Display adj set range 0 to 99999999 Unit Number of sheets Default value 0 T 5 88 T CNTR COPIER COUNTER T CNTR YELLOW Y Toner Container counter Lv 1 Details To count up in the unit of 0 1 Y color Toner Conta...

Page 715: ...f black video count Small size 1 Large size 1 Use case When checking distribution of video count T 5 90 V2 CNTR COPIER COUNTER V2 CNTR TOTAL Video count total counter Lv 1 Details To display distribution of total video count for each color Small size 1 Large size 2 Use case When checking distribution of video count YELLOW Video count Y counter Lv 1 Details To display distribution of yellow video c...

Page 716: ...nversion basis Use case When checking durability of Fixing Assembly Adj set operate method To clear the counter value Select the item and then press Clear key To change the estimated life Select the item enter the value and then press OK key Caution When clearing the counter press Clear key at FX BLT U and FX BLT L Related service mode COPIER COUNTER DRBL 1 FX BLT U FX BLT L T 5 92 ...

Page 717: ...5 489 5 ...

Page 718: ...5 5 490 ...

Page 719: ...5 491 5 ...

Page 720: ...5 5 492 ...

Page 721: ...5 493 5 ...

Page 722: ...5 5 494 ...

Page 723: ...5 495 5 ...

Page 724: ...5 5 496 ...

Page 725: ...5 497 5 ...

Page 726: ...5 5 498 ...

Page 727: ...5 499 5 ...

Page 728: ...5 5 500 ...

Page 729: ...age Lv 1 Details To display the light receiving voltage value for the Lead Sensor Use case When jams frequently occur Adj set operate method Remove and insert the paper at the sensor position and check the value at presence absence of the paper Display adj set range 0 to 255 Appropriate target value At the presence of paper 123 or lower At the absence of paper 179 or higher DRSN LMN Dis of Deliver...

Page 730: ...r PCB clearing RAM data Adj set operate method Enter the setting value and then press OK key Display adj set range 20 to 20 Unit 0 10 Default value 0 ADJMSCN1 Zoom adj in 2 sided horz scan way front Lv 1 Details To make a fine adjustment of the front side image magnification in horizontal scanning direction at the time of DADF duplex scanning As the value is incremented by 1 the image is reduced b...

Page 731: ...range 0 to 9 0 Pickup Motor M1 1 Feed Motor M2 2 Registration Motor M3 3 Read Motor M4 4 Delivery Motor M5 5 Disengagement Motor 1 M6 6 Disengagement Motor 2 M7 7 Tray Lifter Motor M8 8 Glass Shift Motor M9 9 Pickup Roller Unit Lifter Motor M10 Related service mode FEEDER FUNCTION MTR ON TRY A4 Adj of DADF Tray width detect ref 1 A4 Lv 1 Details To automatically adjust the paper width detection re...

Page 732: ...p Solenoid SL2 Related service mode FEEDER FUNCTION SL ON FEEDER FUNCTION SL ON Operation check of DADF Solenoid Lv 1 Details To start operation check for the solenoid specified by SL CHK Use case At operation check Adj set operate method 1 Select the item and then press OK key The unit operates for approximately 5 seconds and automatically stops 2 Press OK key The operation check is completed Cau...

Page 733: ...5 505 5 ...

Page 734: ...5 5 506 ...

Page 735: ...5 507 5 ...

Page 736: ... 0 Default value 0 SORTER ADJUST PF A3Z2 Adj of A3 Z fold position 2nd PFU Lv 1 Details To adjust the 2nd fold position of A3 paper Z fold position on Paper Folding Unit As the value is incremented by 1 the fold position moves by 0 5mm Use case When the fold position adjustment in user mode is inadequate Adj set operate method Enter the setting value and then press OK key Display adj set range 65 ...

Page 737: ... then press OK key Display adj set range 65 to 65 Unit 0 5 mm Appropriate target value 0 Default value 0 SORTER ADJUST PF LDRZ2 Adj of LDR Z fold position 2nd PFU Lv 1 Details To adjust the 2nd fold position of LDR paper Z fold position on Paper Folding Unit As the value is incremented by 1 the fold position moves by 0 5mm Use case When the fold position adjustment in user mode is inadequate Adj s...

Page 738: ... then press OK key Display adj set range 30 to 75 Unit 0 5 mm Appropriate target value 0 Default value 0 SORTER ADJUST PF A4RC2 Adj of A4R C fold position 2nd PFU Lv 1 Details To adjust the 2nd fold position of A4R paper C fold position on Paper Folding Unit As the value is incremented by 1 the fold position moves by 0 5mm Use case When the fold position adjustment in user mode is inadequate Adj s...

Page 739: ...alue and then press OK key Display adj set range 65 to 65 Unit 0 5 mm Appropriate target value 0 Default value 0 SORTER ADJUST PFLTRR32 Adj of LTRR out 3 fold pstn 2nd PFU Lv 1 Details To adjust the 2nd fold position of LTRR paper out 3 fold position on Paper Folding Unit As the value is incremented by 1 the fold position moves by 0 5mm Use case When the fold position adjustment in user mode is in...

Page 740: ...nd then press OK key Display adj set range 75 to 30 Unit 0 5 mm Appropriate target value 0 Default value 0 SORTER ADJUST PFLTRR21 Adj of LTRR 2 fold position 1st PFU Lv 1 Details To adjust the 1st fold position of LTRR paper 2 fold position on Paper Folding Unit As the value is incremented by 1 the fold position moves by 0 5mm Use case When the fold position adjustment in user mode is inadequate A...

Page 741: ... position on Finisher As the value is incremented by 1 the staple position moves by 0 1mm Toward front Toward rear Use case When the front rear 2 staple position is displaced Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 50 to 50 Unit 0 1 mm BFF SFT Paper displace amount on buffer Bklt Lv 1 Details To adjust the pap...

Page 742: ...the trimming position is displaced on the paper stack larger than A4 size Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 50 to 50 Unit 0 1 mm Appropriate target value 0 SORTER ADJUST BFF SFT2 Paper displace amount on buffer Bklt Lv 1 Details To adjust the paper displacement amount on Finisher Buffer Assembly As the v...

Page 743: ... value 0 SORTER ADJUST SDL RLHD Adj Sddl Sttch Diseng Roll fold position Lv 1 Details To adjust the fold position of Saddle Stitcher Disengagement Roller As the value is incremented by 1 the fold position moves by mm Use case When the feed failure with thin paper etc occurs on the Saddle Stitcher Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power sw...

Page 744: ...alue and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 50 Unit 1 msec SORTER ADJUST RTR DWLT Adj Ppr Rtn Roll fall tmg LTR Fin A1 Lv 1 Details To adjust the Paper Return Roller fall timing when LTR size paper is waited in the buffer path As the value is incremented by 1 the fall timing becomes early by 1msec Use case When misalignment occurs in LTR size buffer pa...

Page 745: ...eed direction Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 2 to 4 Unit 1 mm Appropriate target value 2 SORTER ADJUST ST ALG1 Adj Stacker A4 size align pstn Fin B1 Lv 1 Details To adjust the A4 size paper alignment position As the value is incremented by 1 the travel length of the Alignment Plate is increased by 0 4...

Page 746: ...ter the setting value and then press OK key Display adj set range 4 to 2 Unit 1 mm Appropriate target value 0 Default value 0 SORTER ADJUST PRCS RET Adj Process Tray return amount Fin B1 Lv 1 Details To adjust the pull back amount of the paper on the Processing Tray As the value is incremented by 1 the pull back amount is decreased by 1 4mm Use case When the paper is bent in the Processing Tray Ad...

Page 747: ...ls Set 1 when the operation noise after switching the Stack Tray is loud When 1 is set the Stack Tray rise operation becomes slow Use case When the operation noise after switching the Stack Tray is loud Adj set operate method Enter the setting value and then press OK key Display adj set range 0 to 1 0 OFF 1 ON Default value 0 TRY SU Set tray switching speedup mode Fin B1 Lv 1 Details Set 1 when th...

Page 748: ...r PCB Adj set operate method Select the item and then press OK key FIN BK R Controller PCB backup data read Staple Lv 1 Details To read the backup data from Finisher Controller PCB and save to the hard disk Use case When replacing the Finisher Controller PCB Adj set operate method Select the item and then press OK key Display adj set range In processing ACTIVE At normal termination OK At abnormal ...

Page 749: ...R FUNCTION VR2 LTRR Adj Lower Tray width vol LTRR Inserter Lv 1 Details To adjust the paper minimum width LTRR of Inserter Lower Tray automatically Use case When the size mismatch jam is incorrectly detected at the pickup from Inserter Lower Tray Adj set operate method 1 Set the LTRR paper on the Inserter Lower Tray and align it with the width of Slide Guide 2 Select the item and then press OK key...

Page 750: ...d then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Normal 1 Wider Default value 2 MD SPRTN Set restriction at Finisher error Staple Lv 1 Details To set whether to stop the machine when an error occurs at Finisher Use case When preferring to run the machine at Finisher error occurrence Adj set operate method 1 Enter the setting value and then press OK key 2 Turn ...

Page 751: ...eases Display adj set range 0 to 1 0 ON 1 OFF Default value 0 SORTER OPTION 1SHT SRT Setting of 1 sheet Offset Collate Fin A1 Lv 1 Details To set ON OFF of Offset Collate for 1 sheet document When 1 is set Offset Collate for 1 sheet document is enabled but the paper is not appropriately stacked Use case When preferring to execute 1 sheet Offset Collate with low stacking condition Adj set operate m...

Page 752: ...ON BUFF MX2 Buffer at mix weight sort staple Fin A1 Lv 1 Details To set ON OFF of buffer operation when mixing papers which weights are different When 1 is set productivity of sort and staple mode of Finisher is improved but the stacking condition decreases Use case When improving productivity of sort and staple mode in the case of mixing papers which weights are different Adj set operate method 1...

Page 753: ... ON the main power switch Display adj set range 0 to 1 0 Normal 1 Priority on productivity Default value 0 SLD BCK Set bleed thru improvement mode Fin A1 Lv 1 Details When the back of the coated paper as the cover is soiled set 1 2 Use case When the back of paper is soiled while coated paper is used as cover Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the m...

Page 754: ...5 5 526 ...

Page 755: ...5 527 5 ...

Page 756: ...5 5 528 ...

Page 757: ...5 529 5 ...

Page 758: ...5 5 530 ...

Page 759: ...5 531 5 ...

Page 760: ...5 5 532 ...

Page 761: ...5 533 5 ...

Page 762: ...5 5 534 ...

Page 763: ...5 535 5 ...

Page 764: ... range 0 to 1 0 Hide 1 Display Default value 0 MENU 4 Hide dis of printer setting menu level 4 Lv 2 Details To set whether to display or hide the level 4 of printer setting menu Use case Upon user s request Adj set operate method 1 Enter the setting value and then press OK key 2 Turn OFF ON the main power switch Display adj set range 0 to 1 0 Hide 1 Display Default value 0 SURF OFF UFR board funct...

Page 765: ...5 537 5 ...

Page 766: ...05 Remote copy mono color 2 yes 006 Remote copy black and white 1 yes 007 Remote copy black and white 2 yes 008 Remote copy full color large yes 009 Remote copy full color small yes 010 Remote copy mono color large yes 011 Remote copy mono color small yes 012 Remote copy black and white large yes 013 Remote copy black and white small yes 014 Remote copy full color mono color large yes 015 Remote c...

Page 767: ...ll color 2 T 5 100 Valid or invalid Number Counter Details yes 132 Total A black and white 1 yes 133 Total A black and white 2 yes 134 Total A mono color large yes 135 Total A mono color small yes 136 Total A black and white large yes 137 Total A black and white small yes 138 Total A 1 double sided yes 139 Total A 2 double sided yes 140 large A double sided yes 141 small A double sided yes 142 Tot...

Page 768: ...te 1 yes 222 Copy black and white 2 yes 223 Copy full color large yes 224 Copy full color small yes 225 Copy mono color large yes 226 Copy mono color small yes 227 Copy black and white large yes 228 Copy black and white small yes 229 Copy full color mono color large yes 230 Copy full color mono color small yes 231 Copy full color mono color 2 yes 232 Copy full color mono color 1 yes 233 Copy full ...

Page 769: ...copy black and white large double sided yes 294 Local copy black and white small double sided T 5 102 300 to 399 Valid or invalid Number Counter Details yes 301 Print Total 1 yes 302 Print Total 2 yes 303 Print large yes 304 Print small yes 305 Print A Total 1 yes 306 Print A Total 2 yes 307 Print A large yes 308 Print A small yes 309 Print full color 1 yes 310 Print full color 2 yes 311 Print mon...

Page 770: ... 418 Copy print full color smal l double sided yes 419 Copy print mono color large double sided yes 420 Copy print mono color small double sided yes 421 Copy print black and white large double sided T 5 103 Valid or invalid Number Counter Details yes 422 Copy print black and white smal double sided yes 431 Clear mixed mono clear total 1 yes 432 Clear mixed mono clear total 2 yes 433 Clear mixed mo...

Page 771: ...r large double sided yes 622 Box print full color small double sided yes 623 Box print mono color large double sided yes 624 Box print mono color smal l double sided yes 625 Box print black and white large double sided yes 626 Box print black and white small double sided 700 to 799 Valid or invalid Number Counter Details yes 701 Reception print Total 1 yes 702 Reception print Total 2 yes 703 Recep...

Page 772: ...uble sided yes 757 Nnetwork print black and white large double sided yes 758 Nnetwork print black and white smal l double sided yes 759 Mobile print Total 1 yes 760 Mobile print Total 2 yes 761 Mobile print large Valid or invalid Number Counter Details yes 762 Mobile print small yes 763 Mobile print full color 1 yes 764 Mobile print full color 2 yes 765 Mobile print black and white 1 yes 766 Mobil...

Page 773: ...sion scan total 6 color yes 930 Transmission scan total 6 black and white no 931 Transmission scan total 7 color T 5 108 Valid or invalid Number Counter Details no 932 Transmission scan total 7 black and white no 933 Transmission scan total 8 color no 934 Transmission scan total 8 black and white no 935 Universal transmission scan total color no 936 Universal transmission scan total black and whit...

Page 774: ...nit laser scanning system or transfer unit F 5 2 Full Area Half Tone TYPE 5 This test print can mainly check transfer failure black line white line and pitch unevenness COLOR M 1 COLOR Y C K 0 NOTE Output by every developing color is available by specifying the developing color COLOR Y M C K in the following service mode COPIER TEST PG In the case of changing density of the test print execute foll...

Page 775: ...each color balance among each color and white line by developing 1 Solid density of each color and balance among each color Density is not extremely light In the case of light density with a certain color it may be caused by the developer of the color in question or fault of primary transfer roller laser scanning system or high voltage system 2 White black line If there is white black line with a ...

Page 776: ...ormance of each color YMCBk and foggy image Light Areas White Area White Area 1 Gray balance Check to see if the output comes with even density of each color at gray scale area 2 Gradation performance Check gradation performance and density difference of each color YMCBk 3 Foggy image If there is foggy image at the white area it may be caused by fault of developing system or photosensitive drum or...

Page 777: ...6 6 Parts Replacement and Cleaning List of Parts ...

Page 778: ...ist of Main Unit 6 Laser Scanner Unit Bk 5 Laser Scanner Unit C 4 Laser Scanner Unit M 3 Laser Scanner Unit Y 7 Process Unit Y 8 Process Unit M 9 Process Unit C 10 Process Unit Bk 2 Hopper Unit Color 1 Hopper Unit Bk F 6 1 ...

Page 779: ... the Laser Scanner Unit page 4 4 5 Laser Scanner Unit C FM3 5000 Removing the Laser Scanner Unit page 4 4 6 Laser Scanner Unit Bk FM3 5001 Removing the Laser Scanner Unit page 4 4 7 Process Unit Y NPN Removing the Developing Assembly Y M C and the Drum Unit Y M C page 4 1 8 Process Unit M NPN Removing the Developing Assembly Y M C and the Drum Unit Y M C page 4 1 9 Process Unit C NPN Removing the ...

Page 780: ...3 Fixing Feed Unit 12 Fixing Unit 18 Pickup Unit Right Deck 17 Pickup Unit Left Deck 19 Pickup Unit Cassette 3 20 Pickup Unit Cassette 4 16 Pre Fixing Paper Feed Unit 15 Secondary Transfer Unit 14 Registration Unit F 6 2 ...

Page 781: ...xing Feed Unit NPN Removing the Fixing Feed Unit page 4 38 14 Registration Unit FM3 4758 Removing the Registration Unit page 4 32 15 Secondary Transfer Unit FM3 4840 16 Pre Fixing Paper Feed Unit FM3 4760 17 Pickup Unit Left Deck FM3 4745 18 Pickup Unit Right Deck FM3 4744 19 Pickup Unit Cassette 3 FM3 4746 20 Pickup Unit Cassette 4 FM3 4746 T 6 2 ...

Page 782: ...6 6 6 24 Multi purpose Tray Pickup Unit 23 Upright Control Panel Unit 22 Flat Control Panel Unit 25 Vertical Path Unit 21 Reverse Delivery Unit F 6 3 ...

Page 783: ...y Unit FM3 4756 22 Flat Control Panel Unit FM3 8262 Removing the Flat Control Panel Unit page 4 4 23 Upright Control Panel Unit FM3 4810 Removing the Upright Control Panel Unit page 4 9 24 Multi purpose Pickup Unit FM3 4761 25 Vertical Path Unit FM3 4762 T 6 3 ...

Page 784: ...6 6 8 26 Pickup Drive Unit 26 3 Deck Drive Unit 26 2 Cassette Drive Unit 26 1 Vertical Path Drive Unit 26 4 Multi Pickup Drive Unit 28 Drum Drive Unit Color 27 Drum Drive Unit Bk F 6 4 ...

Page 785: ...th Drive Unit FM3 9985 26 2 Cassette Drive Unit FM3 4806 26 3 Deck Drive Unit FM3 4807 26 4 Multi Pickup Drive Unit FM3 4807 27 Drum Drive Unit Bk FM3 4726 Removing the Drum Drive Unit Bk page 4 118 28 Drum Drive Unit Color FM3 4727 Removing the Drum Drive Unit Y M C page 4 123 T 6 4 ...

Page 786: ...emoving the ITB Unit page 4 57 SL5 Right Deck Pickup Solenoid Pickup Unit FK2 7917 Removing Cassette 3 Cassette 4 and Right Deck Pickup Unit page 4 13 SL6 Left Deck Pickup Solenoid Pickup Unit FK2 7917 Removing the Left Deck Pickup Unit page 4 14 SL7 Cassette 3 Pickup Solenoid Pickup Unit FK2 7917 Removing Cassette 3 Cassette 4 and Right Deck Pickup Unit page 4 13 SL8 Cassette 4 Pickup Solenoid Pi...

Page 787: ...nt during parts replacemen Reference SL2 Delivery Flapper Solenoid Reverse Delivery Unit FL2 8909 SL3 Reverse Upper Wheel Detachment Solenoid Reverse Delivery Unit FM3 4889 SL4 Multi purpose Tray Pickup Solenoid Multi purpose Tray Pickup Unit FK2 0115 Removing the Multi purpose Pickup Tray Unit page 4 11 F 6 6 T 6 6 ...

Page 788: ...6 6 12 List of Motor M27 M28 M26 M29 F 6 7 ...

Page 789: ...ment Reference M26 Developing Stirring Motor Y Product configuration FK2 7303 M27 Developing Stirring Motor C Product configuration FK2 7303 M28 Developing Stirring Motor M Product configuration FM3 9957 M29 Developing Stirring Motor Bk Product configuration FM3 9958 T 6 7 ...

Page 790: ...Scanner Unit Y Laser Scanner Unit M Laser Scanner Unit C Laser Scanner Unit Bk M9 M10 M15 M12 M6 M13 M16 Laser Scanner Unit Hopper Unit M80 M81 M82 M83 M84 M8 M17 M14 M11 M85 M86 Color Hopper Unit Bk Hopper Unit F 6 8 ...

Page 791: ...er and Stirring Supply Motor C Hopper Unit FK2 7893 Removing the Hopper Unit Y M C page 4 138 M16 Toner Container Drive Motor C Hopper Unit FK2 7895 Removing the Hopper Unit Y M C page 4 138 M17 Wiper Rotation Motor C Hopper Unit FL3 2303 Removing the Hopper Unit Y M C page 4 138 M80 Laser Scanner Motor Y Laser Scanner Unit FK2 8964 Laser Scanner Unit page 2 6 Removing the Laser Scanner Unit page ...

Page 792: ...6 6 16 M38 M37 M3 M5 M4 M2 M1 Reverse Delivery Unit Process Unit Bk ITB Unit F 6 9 ...

Page 793: ...g Assembly Y M C and the Drum Unit Y M C page 4 1 M2 Pre transfer Charging Wire Cleaning Motor Process Unit Bk FL3 2303 Removing the Developing Assembly Y M C and the Drum Unit Y M C page 4 1 M3 ITB Drive Motor ITB Unit FK2 7896 ITB page 2 12 Removing the ITB Unit page 4 57 M4 Steering Drive Motor ITB Unit FK2 7900 ITB page 2 12 Removing the ITB Unit page 4 57 M5 Primary Transfer Roller Detachment...

Page 794: ...6 6 18 Fixing Unit Secondary Transfer Registration Unit Fixing Feed Unit M47 M48 M46 M34 M35 M33 M32 M49 Pre Fixig Paper Feed Unit Secondary Transfer Unit Registration Unit M31 F 6 10 ...

Page 795: ...g Motor Fixing Unit FK2 7899 Removing the Fixing Motor page 4 32 M49 Pressure Belt Displacement Control Motor Fixing Unit FK2 2523 Removing the Pressure Belt Unit page 4 9 M31 Secondary Transfer Roller Detachment Motor Secondary Transfer Registration Unit FK2 7903 M34 Registration Motor Secondary Transfer Registration Unit FK2 7905 M35 Pre fixing Feed Motor Secondary Transfer Registration Unit FK2...

Page 796: ...6 6 20 M18 M30 M24 M22 M20 Developing Drum Drive Unit Pickup Drive Unit Color Drum Drive Unit Bk Drum Drive Unit M36 M40 M39 M45 M44 M41 M42 M43 M19 M25 M23 M21 F 6 11 ...

Page 797: ...leeve Drive Motor C Developing Drum Drive Unit FK2 7897 M25 Drum Motor C Developing Drum Drive Unit FM4 6616 M30 Drum Cleaning and Waste Toner Feed Drive Motor Developing Drum Drive Unit FK2 7897 M36 Pre registration Multi purpose Tray Drive Motor Pickup Drive Unit FK2 7909 M39 Cassette Vertical Path Motor Pickup Drive Unit FK2 7907 M40 Right Deck Vertical Path Motor Pickup Drive Unit FK2 7907 M41...

Page 798: ...6 6 22 List of Fan FM20 FM19 FM14 FM9 FM8 FM7 FM2 FM6 FM22 FM3 FM18 FM4 FM1 FM5 FM21 F 6 12 ...

Page 799: ...guration FL3 4095 FM6 Fixing Heat Fan Product configuration FL3 4349 FM7 IH Power Supply Fan Product configuration FK2 3679 FM8 Power Supply Fan 1 Product configuration FK2 6818 FM9 Power Supply Fan 2 Product configuration FK2 6818 FM14 Power Supply Cooling Fan 38V Product configuration FK2 7241 FM18 Hopper Cooling Fan Product configuration FK2 3149 FM19 Controller Cooling Fan 1 Product configurat...

Page 800: ...6 6 24 Reverse Delivery Unit Secondary Transfer Registration Unit FM16 FM15 FM10 FM12 FM13 FM11 FM23 FM24 Pre Fixig Paper Feed Unit Secondary Transfer Unit Registration Unit F 6 13 ...

Page 801: ...livery Unit FK2 0472 FM13 Delivery Heat Fan 4 Reverse Delivery Unit FK2 0472 FM15 Pressure Belt Cooling Fan Front Secondary Transfer Registration Unit FK2 3149 FM16 Pressure Belt Cooling Fan Rear Secondary Transfer Registration Unit FK2 6465 FM23 Anti adhesion Fan 1 Reverse Delivery Unit FL2 9823 FM24 Anti adhesion Fan 2 Reverse Delivery Unit FL2 9823 T 6 13 List of Sensor PS46 PS43 PS47 PS48 PS44...

Page 802: ...1 Product configuration WG8 5848 PS44 Left Deck Paper Level Sensor 2 Product configuration WG8 5848 PS45 Cassette 3 Paper Level Sensor 1 Product configuration WG8 5848 PS46 Cassette 3 Paper Level Sensor 2 Product configuration WG8 5848 PS47 Cassette 4 Paper Level Sensor 1 Product configuration WG8 5848 PS48 Cassette 4 Paper Level Sensor 2 Product configuration WG8 5848 PS80 Front Cover Sensor Prod...

Page 803: ...nit Fixing Unit Secondary Transfer Registration Unit PS75 PS74 PS77 PS76 PS73 PS72 PS69 PS23 PS24 PS25 PS26 PS27 PS22 PS28 PS29 PS30 PS78 PS71 PS70 Pre Fixig Paper Feed Unit Secondary Transfer Unit Registration Unit F 6 15 ...

Page 804: ...83 PS77 Pressure Belt Position Sensor 2 Fixing Unit WG8 5783 PS78 Pressure Belt HP Sensor Fixing Unit WG8 5848 PS22 Secondary Transfer Roller Detachment HP Sensor Secondary Transfer Registration Unit WG8 5848 PS23 Post secondary Transfer Sensor Secondary Transfer Registration Unit FK2 6470 PS28 Registration Sensor Secondary Transfer Registration Unit WG8 5848 PS29 Transparency Sensor Secondary Tra...

Page 805: ...s Unit Bk Process Unit Y M C Pickup Unit PS84 PS6 PS10 PS13 PS16 PS7 TS1 TS2 TS3 TS4 PS56 PS55 PS54 PS57 PS58 PS53 PS51 PS49 PS52 PS50 Left Deck Pickup PS63 PS61 PS59 PS62 PS60 PS68 PS66 PS64 PS67 PS65 Cassette 4 Pickup Cassette 3 Pickup Right Deck Pickup Color Hopper Unit Bk Hopper Unit F 6 16 ...

Page 806: ...r Container Phase Sensor Bk Hopper Unit WG8 5848 Removing the Hopper Unit Bk page 4 128 TS5 Hopper Toner Level Sensor Bk Hopper Unit FK2 0590 Removing the Hopper Unit Bk page 4 128 TS6 Hopper Toner Level Sensor Y Hopper Unit FK2 0590 Removing the Hopper Unit Y M C page 4 138 TS7 Hopper Toner Level Sensor M Hopper Unit FK2 0590 Removing the Hopper Unit Y M C page 4 138 TS8 Hopper Toner Level Sensor...

Page 807: ...Unit WG8 5848 Removing Cassette 3 Cassette 4 and Right Deck Pickup Unit page 4 13 PS64 Cassette 4 Pickup Sensor Pickup Unit WG8 5848 Removing Cassette 3 Cassette 4 and Right Deck Pickup Unit page 4 13 PS65 Cassette 4 Upper Limit Sensor Pickup Unit WG8 5848 Removing Cassette 3 Cassette 4 and Right Deck Pickup Unit page 4 13 PS66 Cassette 4 Paper Sensor Pickup Unit WG8 5848 Removing Cassette 3 Casse...

Page 808: ...6 6 32 PS36 ITB Unit Multi purpose Tray Pickup Unit Reverse Delivery Unit Vertical Path Unit PS5 PS3 PS4 PS37 PS38 PS33 PS32 PS34 PS40 PS39 PS31 PS79 PS2 PS19 PS21 PS20 F 6 17 ...

Page 809: ... Unit FM3 9945 ITB page 2 12 Removing the ITB Unit page 4 57 PS21 Patch Sensor ITB Unit FK2 7867 Patch Sensor Unit page 2 12 Removing the Patch Sensor Unit page 4 85 PS37 Multi purpose Tray Paper Sensor Multi purpose Pickup Unit WG8 5848 PS38 Multi purpose Tray Last Paper Sensor Multi purpose Pickup Unit WG8 5848 PS79 Multi purpose Tray Cover Sensor Multi purpose Pickup Unit WG8 5848 PS31 Outer De...

Page 810: ...6 6 34 Lamp Heater others THM6 THM5 ENV1 H6 ELB2 ELB1 IL1 IL2 F 6 18 ...

Page 811: ...ence H6 Cassette Heater Product configuration FM3 8915 ELB1 Leakage Breaker 1 Product configuration FK2 7358 100V FK2 7359 120V FK2 7357 230V ELB2 Leakage Breaker 2 Product configuration FK2 7358 IL1 Inlet Product configuration FM4 1462 IL2 Inlet Product configuration FM4 1462 T 6 18 ...

Page 812: ...6 6 36 H1 ITB Unit Fixing Unit Process Unit Bk H3 VR1 H2 LED1 THM1 2 THM3 TP1 THM4 THM2 H4 TP2 THM1 1 THM1 3 H5 D D LED3 LED4 LED2 Process Unit Y M C F 6 19 ...

Page 813: ...exposure LED Bk ITB Unit FM3 4867 ITB page 2 12 Removing the ITB Unit page 4 57 VR1 ITB Unit Varistor ITB Unit FL3 2302 ITB page 2 12 Removing the ITB Unit page 4 57 THM1 1 Fixing Main Thermistor Fixing Unit FK2 7868 THM1 2 Fixing Sub Thermistor 1 Fixing Unit THM1 3 Fixing Sub Thermistor 2 Fixing Unit THM2 Pressure Main Thermistor Fixing Unit FK2 2537 THM3 Pressure Sub Thermistor 1 Fixing Unit FK2...

Page 814: ...6 6 38 List of Switch SW9 SW10 SW11 SW7 SW12 SW13 SW1 SW2 SW16 SW17 SW14 SW15 F 6 20 ...

Page 815: ...tection Switch Product configuration FM4 1426 SW11 Main Switch Product configuration FK2 7918 SW12 Environment Switch Product configuration WC1 5179 SW13 Cassette Heater Switch Product configuration WC1 5179 SW14 Cassette 3 Size Detection Switch 1 Product configuration WC2 5680 SW15 Cassette 3 Size Detection Switch 2 Product configuration WC2 5680 SW16 Cassette 4 Size Detection Switch 1 Product co...

Page 816: ...nit Multi purpose Tray Pickup Unit SW5 SW3 No Name Main Unit Service Parts No Reference SW5 Delivery Door Switch Reverse Delivery Unit FM4 1342 SW3 Multi purpose Tray Unit Switch Multi purpose Pickup Unit FM4 1392 F 6 21 T 6 21 ...

Page 817: ...6 41 6 List of PCB B B UN27 Secondary Transfer Registration Unit Process Unit Y M C Fixing Unit UN67 UN66 Pre Fixig Paper Feed Unit Secondary Transfer Unit Registration Unit UN15 UN14 F 6 22 ...

Page 818: ...N15 Developing Assembly Inner Temperature Detection PCB C Bk Process Unit Y M C FM3 9583 Removing the Developing Assembly Y M C and the Drum Unit Y M C page 4 1 UN66 Secondary Transfer High Voltage Contact Resistance Secondary Transfer Registration Unit FM3 7196 UN67 Secondary Transfer Static Elimination High Voltage Contact Resistance Secondary Transfer Registration Unit FM3 7196 UN27 Pressure Ma...

Page 819: ...r Unit ITB Unit Fixing Feed Unit Laser Scanner Unit Bk Laser Scanner Unit C Laser Scanner Unit M Laser Scanner Unit Y UN101 UN102 UN17 UN16 UN104 UN106 UN108 UN103 UN105 UN107 UN49 UN48 UN5 UN62 UN63 UN64 UN65 UN28 F 6 23 ...

Page 820: ...4 UN108 BD PCB Bk Laser Scanner Unit FM4 2368 Laser Scanner Unit page 2 6 Removing the Laser Scanner Unit page 4 4 UN16 ITB Drive Roller Speed Detection PCB 1 ITB Unit FM3 9577 ITB page 2 12 Removing the ITB Unit page 4 57 UN17 ITB Drive Roller Speed Detection PCB 2 ITB Unit FM3 9577 ITB page 2 12 Removing the ITB Unit page 4 57 UN28 ITB Relay PCB ITB Unit FM3 9597 ITB page 2 12 Removing the ITB U...

Page 821: ...lti purpose Tray Pickup Unit Flat Control Panel Unit Vertical Control Panel Unit UN112 UN113 UN111 UN114 UN110 UN26 Sub Key PCB Volume PCB Inverter PCB Tally Lamp PCB CPU PCB Ten Key PCB USB HUB PCB UN109 F 6 24 ...

Page 822: ... Detection PCB Multi purpose Pickup Unit FH7 7600 UN109 Hub PCB Control Panel Unit FM4 1199 UN110 Ten Key PCB Control Panel Unit FM4 1194 UN111 CPU PCB Control Panel Unit FM4 1193 UN112 Sub Key PCB Control Panel Unit FM4 1195 UN113 Volume PCB Control Panel Unit FM4 1183 UN114 Inverter PCB Control Panel Unit FM4 1196 T 6 24 ...

Page 823: ...6 47 6 UN39 UN42 UN41 UN40 UN7 UN38 UN37 UN50 UN59 UN60 UN61 UN31 32 UN11 12 UN8 9 10 UN35 UN36 UN80 UN30 UN34 UN33 UN4 UN46 UN6 UN29 UN43 UN47 UN44 UN45 UN56 UN55 UN51 UN52 UN53 UN54 UN57 UN58 F 6 25 ...

Page 824: ... PCB Product configuration FM3 9578 UN8 AC Driver PCB Product configuration FM3 9579 UN9 AC Driver PCB Product configuration FM3 9596 UN10 AC Driver PCB Product configuration FM3 9580 UN11 Drum Heater Driver PCB Product configuration FM3 9581 UN12 Drum Heater Driver PCB Product configuration FM3 9582 UN30 IH Power Supply PCB Product configuration FK3 9584 UN31 All night Power Supply PCB Product co...

Page 825: ...6 49 6 UN3 UN2 UN99 UN1 UN116 UN100 UN115 UN83 F 6 26 ...

Page 826: ...65 AU Removing the Main Controller PCB 1 page 4 3 UN115 Main Controller PCB 1 Product configuration FM4 0745 Main Controller PCB 1 page 2 2 C7065 JP US Removing the Main Controller PCB 1 page 4 3 UN115 Main Controller PCB 1 Product configuration FM4 0746 Main Controller PCB 1 page 2 2 C7055i C7055 Removing the Main Controller PCB 1 page 4 3 UN115 Main Controller PCB 1 Product configuration FM4 075...

Page 827: ...peed Detection PCB Bk 2 Developing Drum Drive Unit FM3 9577 UN20 Drum Speed Detection PCB Y 1 Developing Drum Drive Unit FM3 9577 UN21 Drum Speed Detection PCB Y 2 Developing Drum Drive Unit FM3 9577 UN22 Drum Speed Detection PCB M 1 Developing Drum Drive Unit FM3 9577 UN23 Drum Speed Detection PCB M 2 Developing Drum Drive Unit FM3 9577 UN24 Drum Speed Detection PCB C 1 Developing Drum Drive Unit...

Page 828: ...6 6 52 Connector List 40 39 47 24 28 35 36 41 37 44 32 33 31 29 30 23 43 42 26 22 25 20 27 38 45 30 34 46 21 1 14 17 19 18 16 15 10 9 8 12 7 5 2 6 4 13 11 3 F 6 28 ...

Page 829: ...terface PCB J8170 J8001 J8003 32 J7226 PS76 Pressure Belt Position Sensor 1 10 UN2 J1225 DC Controller Interface PCB J8170 J8001 J8003 33 J7407 THM4 Pressure Sub Thermistor 2 10 UN2 J1225 DC Controller Interface PCB J8170 J8001 J8003 34 J7406 THM3 Pressure Sub Thermistor 1 11 UN2 J1226 DC Controller Interface PCB J8018 35 J2202 UN11 Drum Heater Driver PCB 100V 11 UN2 J1226 DC Controller Interface ...

Page 830: ...6 6 54 1 16 24 43 33 35 39 40 41 38 23 22 48 49 20 42 18 19 17 21 34 26 32 30 29 27 28 31 51 45 37 50 12 11 10 14 9 5 2 6 4 15 13 8 7 52 36 46 3 44 47 25 F 6 29 ...

Page 831: ...ose Tray Cover Sensor 4 UN2 J1243 DC Controller Interface PCB J8017 J8009 34 J7147 M1 Primary Charging Wire Cleaning Motor 4 UN2 J1243 DC Controller Interface PCB J8017 J8009 35 J7148 M2 Pre transfer Charging Wire Cleaning Motor 4 UN2 J1243 DC Controller Interface PCB 36 J3530 UN29 Potential Control PCB 5 UN2 J1244 DC Controller Interface PCB J8165 37 J8057 SW7 Fixing Feed Unit Switch 6 UN2 J1246 ...

Page 832: ...6 6 56 1 2 9 8 7 5 21 47 22 27 20 25 32 35 37 38 39 36 30 26 46 45 31 16 41 15 17 24 33 42 43 44 23 19 40 14 11 12 13 10 29 28 34 18 6 4 3 F 6 30 ...

Page 833: ...or M 6 UN3 J1350 Hopper Driver PCB J8107 27 J7419 PS15 Toner Feed Screw Rotation Sensor M 6 UN3 J1350 Hopper Driver PCB J8107 28 J7101 M12 Hopper and Stirring Supply Motor M 6 UN3 J1350 Hopper Driver PCB J8107 29 J7523 M14 Wiper Rotation Motor M 6 UN3 J1350 Hopper Driver PCB J8108 30 J7127 TS8 Hopper Toner Level Sensor C 6 UN3 J1350 Hopper Driver PCB J8108 31 J7129 PS17 Toner Container Reciprocati...

Page 834: ...6 6 58 1 8 7 5 2 6 4 3 42 41 39 38 16 15 27 20 23 29 28 34 32 35 33 36 37 21 30 24 31 13 14 25 26 10 9 11 12 40 22 17 18 19 F 6 31 ...

Page 835: ...vel Sensor 1 3 UN4 J1404 Pickup Feed Driver PCB J8141 24 J7039 PS46 Cassette 3 Paper Level Sensor 2 4 UN4 J1405 Pickup Feed Driver PCB J8061 J8075 25 J7037 PS40 Vertical Path Sensor 2 4 UN4 J1405 Pickup Feed Driver PCB J8061 26 J7031 PS39 Lower Right Cover Sensor 4 UN4 J1405 Pickup Feed Driver PCB J8090 J8068 27 J7027 PS35 Reverse Vertical Path Sensor 3 5 UN4 J1406 Pickup Feed Driver PCB J8144 28 ...

Page 836: ...6 6 60 1 10 14 12 13 9 8 17 15 16 44 45 43 19 30 36 22 21 23 20 24 33 32 34 31 35 39 38 40 37 41 29 26 27 25 42 28 7 18 5 2 6 4 11 3 F 6 32 ...

Page 837: ...10 27 J7016 PS38 Multi purpose Tray Last Paper Sensor 6 UN4 J1415 Pickup Feed Driver PCB J8059 J8110 28 J7018 UN26 Multi purpose Tray Paper Width Detection PCB 7 UN4 J1416 Pickup Feed Driver PCB 29 J8116 SW10 Waste Toner Screw Lock Detection Switch 8 UN4 J1417 Pickup Feed Driver PCB J2635 30 J7047 SL7 Cassette 3 Pickup Solenoid 8 UN4 J1417 Pickup Feed Driver PCB J2635 31 J7042 PS59 Cassette 3 Pick...

Page 838: ...6 6 62 7 6 5 3 4 2 9 1 42 41 40 38 39 48 47 28 30 31 45 46 29 36 33 35 37 11 10 8 43 58 57 44 22 63 21 12 64 14 15 17 13 16 18 24 20 27 32 23 25 34 26 F 6 33 ...

Page 839: ...6 63 6 19 62 61 60 59 53 54 51 52 49 50 55 56 F 6 34 ...

Page 840: ...J7214 PS22 Secondary Transfer Roller Detachment HP Sensor 7 UN5 J1509 Fixing Feed Driver PCB J8102 39 J7215 PS23 Post secondary Transfer Sensor 8 UN5 J1510 Fixing Feed Driver PCB 9 UN5 J1511 Fixing Feed Driver PCB J8091 40 J7211 PS28 Registration Sensor 9 UN5 J1511 Fixing Feed Driver PCB J8092 41 J7213 PS30 Vertical Path Merging Sensor 9 UN5 J1511 Fixing Feed Driver PCB 42 J7212 PS29 Transparency ...

Page 841: ...e REMARKS 15 UN6 J1920 Drum ITB Driver PCB J8021 61 J7304 M25 Drum Motor C 16 UN6 J1921 Drum ITB Driver PCB 62 J7306 M19 Drum Motor Bk 17 UN6 J1922 Drum ITB Driver PCB J8011 J8047 63 J7318 M3 ITB Drive Motor 18 UN6 J1930 Drum ITB Driver PCB 64 J7231 FM22 Hopper Cooling Suction Fan T 6 33 ...

Page 842: ...6 6 66 49 25 26 22 23 24 29 30 31 24 37 50 43 16 10 4 1 2 3 17 18 F 6 35 ...

Page 843: ...6 67 6 48 28 40 36 42 38 47 51 46 35 45 33 32 34 44 27 14 6 5 7 8 12 13 15 11 20 9 19 21 41 39 54 53 52 F 6 36 ...

Page 844: ...itch 11 UN7 J1813 Relay PCB J8122 J8001 J8025 38 J9003 Fuse PCB 11 UN7 J1813 Relay PCB J8165 SW11 Main Switch 12 UN7 J1814 Relay PCB J8205 39 J3545 UN50 Pre primary Transfer Charging High Voltage PCB Bk 12 UN7 J1814 Relay PCB J8207 40 J3041 UN40 Developing High Voltage PCB Y 12 UN7 J1814 Relay PCB 41 J3021 UN38 Primary Charging High Voltage PCB Color 12 UN7 J1814 Relay PCB 42 J3060 UN47 Primary Tr...

Page 845: ...6 69 6 19 21 22 20 18 2 26 25 3 14 10 4 6 5 11 12 7 8 9 17 23 16 15 24 1 13 F 6 37 ...

Page 846: ...ter Driver PCB 13 UN8 J816 AC Driver PCB 100V ELB2 Leakage Breaker 2 14 UN8 J820 AC Driver PCB 100V 26 J681 UN31 All night Power Supply PCB 100V 1 UN9 J801 AC Driver PCB 120V ELB1 Leakage Breaker 1 2 UN9 J803 AC Driver PCB 120V J8083 J8084 15 J7 UN D Modular PCB 1 line 2 UN9 J803 AC Driver PCB 120V J8083 J8084 16 J601 UN E Modular PCB 2 3 4 line 3 UN9 J804 AC Driver PCB 120V J8124 J8119 SW11 Main ...

Page 847: ...itch 8 UN10 J810 AC Driver PCB 200V J8118 J8187 J8001 H5 Pressure Heater 9 UN10 J812 AC Driver PCB 200V J8241 J8123 J8228 To finisher 9 UN10 J812 AC Driver PCB 200V J8241 J8120 19 J503 UN30 IH Power Supply PCB 10 UN10 J813 AC Driver PCB 200V J8129 J8190 20 J101 UN33 DC Power Supply PCB 12V 10 UN10 J813 AC Driver PCB 200V J8129 J8191 21 J102 UN34 DC Power Supply PCB 24VA 10 UN10 J813 AC Driver PCB ...

Page 848: ...6 6 72 2 1 26 24 13 12 8 11 14 15 10 25 9 20 19 18 3 23 21 22 17 16 5 4 7 6 F 6 38 ...

Page 849: ...elay PCB J8045 20 J7416 PS3 Steering Drive HP Sensor 4 UN28 J2701 ITB Relay PCB 21 J7113 PS4 Primary Transfer Roller Detachment HP Sensor 5 UN28 J2702 ITB Relay PCB 22 J7415 PS2 ITB Displacement Sensor 6 UN28 J2703 ITB Relay PCB 7 UN28 J2704 ITB Relay PCB J8046 23 J7528 PS5 ITB HP Sensor 8 UN29 J3531 Potential Control PCB 24 J8073 Potential Sensor 9 UN30 J510 IH Power Supply PCB J8026 H4 IH Coil 9...

Page 850: ...4 1 19 20 17 18 4 6 3 5 34 35 2 16 15 23 24 22 61 21 26 65 64 27 66 25 30 29 32 67 63 33 69 68 31 28 13 14 41 7 8 37 10 39 38 9 36 11 12 40 47 46 51 50 54 58 55 48 52 42 49 53 57 60 43 44 45 56 59 62 F 6 39 ...

Page 851: ...ansfer Sub PCB 11 UN47 J3064 Primary Transfer Sub PCB 37 J3570Y UN44 Primary Transfer High Voltage PCB Y 11 UN47 J3064 Primary Transfer Sub PCB 38 J3570M UN45 Primary Transfer High Voltage PCB M 12 UN47 J3065 Primary Transfer Sub PCB 39 J3570C UN46 Primary Transfer High Voltage PCB C 12 UN47 J3065 Primary Transfer Sub PCB 40 J3220 UN43 Primary Transfer High Voltage PCB Bk UN48 Secondary Transfer H...

Page 852: ... PCB J8074 J8076 52 J7532M M81 Laser Scanner Motor M 22 UN100 J5510 Laser Interface PCB 53 J5101M UN103 Laser Driver PCB M 23 UN100 J5511 Laser Interface PCB J8069 J8064 54 J7530C UN106 BD PCB C 23 UN100 J5511 Laser Interface PCB J8069 J8064 55 J7531C M86 Skew Correction Motor C 23 UN100 J5511 Laser Interface PCB J8069 J8064 56 J7532C M82 Laser Scanner Motor C 23 UN100 J5511 Laser Interface PCB 57...

Page 853: ...6 77 6 12 1 3 23 4 8 15 24 25 26 13 16 6 2 9 7 5 10 11 14 19 17 18 21 22 20 33 34 35 28 30 27 29 31 32 F 6 40 ...

Page 854: ... UN115 J1020 Main Controller PCB 1 Flash PCB 14 UN115 J1021 Main Controller PCB 1 USB IF Host 15 UN115 J1022 Main Controller PCB 1 TPM PCB 16 UN115 J1025 Main Controller PCB 1 Expansion Bus F1 17 UN115 J1026 Main Controller PCB 1 CC VI I F CABLE 18 UN115 J1027 Main Controller PCB 1 Copy Card Reader Attachment A1 19 UN115 J1028 Main Controller PCB 1 20 UN115 J1029 Main Controller PCB 1 21 UN115 J10...

Page 855: ...6 79 6 14 2 12 9 15 13 33 29 23 24 25 28 30 17 18 16 21 19 27 22 35 26 36 20 31 34 32 1 3 6 5 7 8 4 11 10 F 6 41 ...

Page 856: ... controller PCB 2 Reader Controller PCB 16 J4 Modular PCB 1 line 27 J103 FAX PCB 1 line Modular PCB 1 line HANDSET G2 17 J604 Modular PCB 2 to 4 lines 28 J204 FAX Control PCB 2 lines 18 J504 Modular PCB 2 to 4 lines 29 J802 FAX Control PCB 3 4 lines 18 J504 Modular PCB 2 to 4 lines 30 J804 FAX Control PCB 2 lines 19 J104 FAX PCB 1 line 31 J303 Pseudo CI PCB Off hook Power Supply PCB 20 J105 FAX PC...

Page 857: ...7 7 Product Overview Specifications Product lineups Basic Configuration ...

Page 858: ...PRO 4 4 sec imageRUNNER ADV C9060 PRO 7065 7055 4 9 sec Color JAPAN imageRUNNER ADV C9075 PRO 6 0 sec imageRUNNER ADV C9065 PRO 7065 7055 6 6 sec Other imageRUNNER ADV C9075 PRO 9070 PRO 9065 PRO 6 0 sec imageRUNNER ADV C9060 PRO 7065 7055 6 6 sec Image gradation 256 gradation Print resolution Max 1200 dpi X 1200 dpi Maximum image guarantee area 313 X 466 6mm Maximum printable area 1 sided 323 x 4...

Page 859: ... paper 106 220 17 5 18 7 9 2 A3 8 9 LDR 16 2 16 2 8 1 A3 7 8 LDR 221 300 T 7 2 Size Mode Paper type Paper basis weight g m2 ImageRUNNER ADVANCE C7065 C7055 Cassette Manual feed Cassette Manual feed Color BW Color BW Color BW Color BW A4 LTR 1 sided Plain paper 52 90 60 0 65 0 36 6 55 0 55 0 36 6 90 105 55 0 60 0 36 6 Thick paper 106 220 30 0 32 5 18 3 27 5 27 5 18 3 221 300 20 0 21 7 12 2 18 3 18 ...

Page 860: ... 90 91 to 105 Color paper 64 to 90 Thick paper 106 to 150 151 to 220 Embossed paper 106 to 150 151 to 220 A4 B5 LTR Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes A3 B4 A4R 11x17 LGL LTRR SRA3 12x18 13x19 Yes No No Yes Yes No Yes Yes Yes B5R EXEC Yes No No Yes Yes No No Yes Yes Yes A5R STMTR Yes No No Yes Yes No Yes Yes No No OFFICIO E OFFICIO B OFFICIO M OFFICIO A OFFICIO A LTR A LTRR G LTRR GLTR GLGL A...

Page 861: ... Yes No Yes A4 B5 LTR Yes No No Yes Yes Yes No Yes No Yes B5R EXEC OFFICIO E OFFICIO B OFFICIO M OFFICIO A OFFICIO A LTR A LTRR GLTR R GLTR GLGL AFLS FLS K8 K16 Irregular size 1 1 to 4 4 Yes No No Yes Yes No No Yes No Yes A5R STMTR Yes No No Yes Yes No No Yes No No K16R No No No Yes Yes No No Yes No No F4A Yes No No Yes Yes No No No No No Irregular size5 Yes No No No No No No No No No EXEC R No No...

Page 862: ... HDD JPN 1TB Other 80GB 80GB Communication method with pickup delivery options Serial Pickup delivery options Some equipments are connected to iR ADV C9075 PRO C9065 PRO only Some equipments are connected to iR ADV C7065 C7055 only F 7 1 F 7 2 T 7 6 Pickup delivery options Applicable options for each model Connectable pickup delivery options differ according to the model Connecting configuration i...

Page 863: ...sertion Unit J1 or Paper Folding Insertion Unit G1 Pickup capacity max 400 sheets 200 sheet each for the upper deck and the lower deck Paper type plain paper recycled paper color paper thick paper coated paper Paper size B5 to 13 X19 2 Paper basis weight 52 to 300g m2 Document Insertion Folding Unit G1 Connection is available with either this Paper Folding Insertion Unit G1or Insertion Unit J1 as ...

Page 864: ...articular conditions Paper basis weight 52 to 300g m2 Booklet Finisher B1 Option for iR ADVANCE C7065 7055 Buffer Path Unit F1 is required at upstream configuration Saddle 16 sheet saddle stitching Buffer Pass Unit F1 Necessary when a finisher is connected Inner Booklet Trimmer A Option for Staple Finisher A1 Booklet Finisher A1 Puncher Unit BE1 Option for Staple Finisher A1 Booklet Finisher A1 Fo...

Page 865: ... of the color original or the B W original under mixed configuration of color and B W originals paper basis weight is 64 to 220 g m2 Stacking capacity max 300 sheets Multi Color Image Reader A1 Simultaneous 2 sided scanning B W 1 SIDED 2 SIDED 600dpi 120 120ipm 300dpi 120 200ipm Color 1 sided 2 sided 600dpi 70 70ipm 300dpi 120 140ipm Paper basis weight 1 sided AB configuration 38 to 220 g m2 Inch ...

Page 866: ...ons and particular conditions Super G3 3rd 4th LineFAX Board AE1 No compulsory options and particular conditions Voice Guidance Kit F1 F2 Consists of the voice guidance PCB and the voice guidance assembly Only for overseas non Japanese models only Voice Operation Kit C1 Consists of the voice operation PCB and the voice operation panel HDD Data Encryption Mirroring Kit C1 No compulsory options and ...

Page 867: ...H1 Universal Send Advanced Feature Set D1 Universal Send Security Feature Set D1 Universal Send Digital User Signature Kit C1 Remote FAX Kit A1 T 7 11 Basic Configuration Functional Configuration The machine may broadly be divided into the following functional system blocks document exposure system block controller system block laser exposure system block image formation system block fixing system...

Page 868: ...7 7 12 ...

Page 869: ...8 8 Upgrading Upgrading ...

Page 870: ...es Key and certiÿcate for encryption communication iAXXXX KEY Yes Yes ADF ADF controller DADF R1 CPU Yes Staple Finisher B1 Booklet Finisher B1 Finisher controller FIN_B1 FIN_CON Yes Yes Staple Finisher B1 Booklet Finisher B1 Saddle controller SDL_CON Yes Yes Booklet Finisher B1 Inserter controller INF_JG INF_CON Yes Insertion Unit J1 Paper Folding Insertion Unit G1 EXP_A1 EXP_CON Yes External 2 3...

Page 871: ...is machine two types of CPU Main Controller PCB 1 and Main Controller PCB 2 are equipped Boot program of each CPU Main Controller PCB 1 and Main Controller PCB 2 is stored in the Flash PCB on the Main Controller PCB 1 ...

Page 872: ...the following download mode Safe Mode download mode A While pressing 2 and 8 keys simultaneously turn ON the main power switch Normal Mode download mode B While pressing 1 and 7 keys simultaneously turn ON the main power switch and select COPIER FUNCTION SYSTEM DOWNLOAD in service mode and press OK F 8 1 Downloading system software Uploading backup data Downloading backup data Backup data System s...

Page 873: ...rading complete Upgrading complete Upgrading complete Upgrading complete Upgrading complete Download Mode iR2270i JPjaxxxx MN dsh iR2270iM JPjaxxxx 1F77 MN PRG iR2270iM ZZjaxxxx 49AD PRG iR2270iW JPjaxxxx 5C16 MN PRG iR2270iW ZZjaxxxx A825 PRG iR2270iF JPjaxxxx DE96 ICC PRG iR2270iW ZZjaxxxx A825 PRG iR2270iG JPjaxxxx EC30 ICC PRG Complete Complete Complete Complete Complete Complete Complete Comp...

Page 874: ... it in safe mode press 2 8 simultaneously If the machine starts in safe mode download the system software again If not replace HDD and download the system software CAUTION It is recommended to download DCON RCON in normal mode DCON RCON may be downloaded in either normal mode or safe mode However if done in safe mode the version information of DCON RCDON will not be obtained In this case DCON RCON...

Reviews: