N. Special Tools, Solvents and Oils
In addition to the standard tools used to service these devices, the following
special tools should also be carried by a service technician, according to the
tool’s rank. For more information on the special tools, solvents, and oils below,
see the
imageRUNNER ADVANCE 6275/6265/6255 Series Service Manual
.
Table 23 – Special Tools List
Description
Part Number
Rank
Appearance
Remarks
Digital Multimeter
FY9-2002-000
A
Use for electrical
checks; for
adjustment of laser
power in
combination with the
laser power
checker.
Cover Switch
TKN-0093
A
Tester Extension Pin
FY9-3038-000
A
Used as a probe
extension when
making electrical
checks.
Tester Extension Pin
(L Shaped)
FY9-3039-000
A
Used as a probe
extension when
making electrical
checks.
Mirror Positioning
Tool
FY9-3046-040
B
Used for positioning
mirror mounts.
NA-3 Test Sheet
FY9-9196-000
A
Used for
adjusting/checking
images.
Electrode for
checking potential
sensor
FY9-3059-000
B
Surface potential
sensor for zero-level
check
MTF TEST SHEET
FY9-9453
N
MTF adjustment
Rank Description
A: Each service person is expected to carry one.
B: Each five or so service persons are expected to carry one.