Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Flat Bed Motor Unit (Copyboard Model) > Procedure
Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Flat Bed Motor Unit (Copyboard Model) > Procedure
2) Press the gear [1] to bend the belt [2], and remove the belt [2] from the gear [3].
CAUTION:
Grease is applied on the shaft [4] of the Contact Image Sensor, so be careful not to let
the belt [2] come in contact with the shaft.
[2]
[4]
F-4-214
[2]
[1]
[3]
F-4-215
3) Remove the Guide Cover [1].
• 1 Claw [2]
[2]
[1]
1x
4) Free the harness [1] and the Grounding Wire [2] from the hole [A] of the Reader Unit and
the Harness Guide [B].
[2]
[1]
[B]
1x
[A]
F-4-216