4
4
4-73
4-73
Disassembly/Assembly > Original Exposure/Feed System (SADF Model) > Removing the Flat Bed Motor Unit (SADF Model) > Procedure
Disassembly/Assembly > Original Exposure/Feed System (SADF Model) > Removing the Flat Bed Motor Unit (SADF Model) > Procedure
■
Procedure
CAUTION:
• Do not lose the 2 spacers [1] of the Contact Image Sensor Unit.
• Do not touch the document reading part [A] of the Contact Image Sensor Unit.
[1]
[A]
F-4-178
1) Move the Contact Image Sensor Unit [1].
[1]
F-4-179
2) Press the gear [1] to bend the belt [2], and remove the belt [2] from the gear [3].
CAUTION:
Grease is applied on the shaft [4] of the Contact Image Sensor, so be careful not to let
the belt [2] come in contact with the shaft.
[2]
[4]
F-4-180
[2]
[1]
[3]
F-4-181