COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
3-33
CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
Figure 3-D505
Figure 3-D506
[4]
[3]
[1]
[2]
[7]
[6]
[5]
[1]
[2]
[3]
Figure 3-D507
3.
Removing the Scanner Home
Position Sensor
1) Remove the rear cover.
2) Free the harness from the wire saddle [1],
and disconnect the connector [2]; then, re-
move the screw [3], and detach the sensor
mount [4].
3) Disconnect the connector [5], and remove
the screw [6]; then, detach the scanner
home position sensor [7].
4.
Removing the Copyboard Glass
1) Remove the rear cover.
2) Free the harness from the wire saddle [1],
and remove the screw [2]; then, detach the
sensor mount [3].