4-21
6) Press [DF-WLVL2] on the touch panel
to highlight.
7) Press [OK].
- The machine executes auto adjustment
(duplex stream reading).
- When the adjustment ends normally, the
machine indicates 'OK!' on the screen.
8) Press the Reset key twice to end service
mode.
4.3.2
Adjustment at Time of
Parts Replacement
4.3.2.1
Adjusting the
Side Guide Plate
0006-2357
1) Remove the 4 mounting screws [1], and
detach the cover [2].
F-4-29
2) Loosen the mounting screws [3] [4];
then, move the original width volume
unit [5] to the front or the rear to make
adjustments.
3) Tighten the screws [3] [4].
4) Attach the cover after the adjustment.
5) Make a copy of the Test Chart once
again to see that the resulting image is as
indicated.
F-4-30
- if A>1 mm, move the volume unit [6]
toward the front.
- if B>1 mm, move the volume unit [6]
toward the rear.
[2]
[1]
[1]
[3]
[4]
[5]
Summary of Contents for DADF-N1
Page 12: ...Chapter 1 Specifications ...
Page 20: ...Chapter 2 Functions ...
Page 37: ...Chapter 2 2 15 F 2 12 Arching Standby for reading Reading of face Delivery Job end ...
Page 67: ...Chapter 3 Parts Replacement Procedure ...
Page 162: ...Chapter 4 Maintenance ...
Page 166: ...Chapter 4 4 3 Be sure to push in the stamp until a click is felt Otherwise jams can occur ...
Page 170: ...F 4 5 F 4 6 1 22 20 24 26 16 21 23 25 27 ...
Page 187: ...F 4 32 VR1 SL1 SL2 M2 PCB1 PCB2 M1 CL1 Chapter 4 4 24 ...
Page 190: ...Chapter 5 Error Code ...
Page 197: ...Appendix ...
Page 199: ......