The EdgeAccess Universal Chassis System
2361 Modem Users Manual
4-14
Table 6 describes the function of each trap:
Table 6: Alarm Trap Option Definitions
Name
Function
1. All Traps
Enables or disables all the traps in this list
2 Inactive Link/Modem Traps
Loss of signal received from attached
equipment
3 Electrical AIS
"All 1's" signal pattern received from
attached equipment
4 Configuration
Incompatibility between local and remote
modem, or between main modem module
and the LIMs attached to it
5 Power Supply
Failure of power supply in the remote
chassis
6 Test
Failure of Bit Error Rate Test (BERT) or
failure in the continuous self-test operation
7 Link Self Test
Failure of fiber between Local and Remote
units
8 Power On Self Test
Failure of Power-On self test
9 Inactive Composite Link
In a redundant configuration, failure of the
redundant or inactive link .
4.4.7 Standalone Modem Alarm Input Settings
The standalone modem allows inputting of alarms from an external device, thus generating a trap,
(if the trap is enabled) when triggered. To enable this feature, do the following:
1. From the Main Menu, type "1" to open the System Configuration screen.
2. Type "3," Link Level Trap Configuration.
3. Look at option 8. If Alarm Input Trap is enabled; the feature is enabled.
4. If Alarm Input Trap is "disabled", type "8," then press the spacebar to "enable" the option.