Installation
FUSE / BREAKER SPECIFICATIONS:
An over-current protection device (circuit breaker or fuse) must be used with this downrigger. Coast Guard re-
quirements dictate that each ungrounded current-carrying conductor must be protected by a manually reset, trip-
free circuit breaker or fuse.
The following breaker size is a recommended guideline:
1 downrigger—30A @ 12 vdc
2 downriggers—60A @ 12 vdc
For additional information, please consult appropriate ABYC (American Boat and Yacht Council) and Coast Guard
requirements.
Reference:
United States Code of Federal Regulations: 33 CFR 183—Boats and Associated Equipment
ABYC E-11: AC and DC Electrical Systems on Boats
Powering Multiple Downriggers
When operating multiple Magnums, run a
maximum of 2 downriggers per dedicated battery
.
Typical Operating Time*:
1 Magnum per battery –
24 hours.
2 Magnums per battery –
10 hours.
*Time based on lab results using a 15lb weight and Deep-Cycle batteries. Actual run time will vary.
Red
( + )
Black ( – )
Connect Multiple
Batteries in Parallel
Summary of Contents for Magnum 10 STX TS
Page 1: ...Owner s Manual Magnum 5 ST Magnum 10 STX Magnum 10 STX TS...
Page 24: ...24 www cannondownriggers com Parts List 1902300 Magnum 5 ST...
Page 26: ...26 www cannondownriggers com Parts List 1902301 Magnum 5 ST E...
Page 28: ...28 www cannondownriggers com Parts List 1902305 Magnum 10 STX...
Page 30: ...30 www cannondownriggers com Parts List 1902306 Magnum 10 STX E...
Page 32: ...32 www cannondownriggers com Parts List 1902310 Magnum 10 STX TS...
Page 34: ...34 www cannondownriggers com Parts List 1902311 Magnum 10 STX TS E...
Page 36: ...36 www cannondownriggers com Wiring Diagram Magnum Series Wiring Diagram...
Page 37: ...37 www cannondownriggers com THIS PAGE INTENTIONALLY LEFT BLANK...