background image

Cannon

This heater is approved for use with Natural and Propane gases.

Please leave instructions with the owner

INBUILT MODELS

CANTIB, CANTIBLP

CANTIBM, CANTIBMLP

USER INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SERVICE INSTRUCTIONS

MAKER’S WARRANTY

20

Authorised service

agents

For further information or spare parts contact the CANNON dis-

tributor in your state.

Sampford & Staff Pty Ltd

421 Smith Street.

Fitzroy, Vic, 3065

Vic/Tas:

(03) 9418 5800

NSW:

(02) 9331 8888

SA/NT:

(08) 8212 7000

Qld:

(07) 3358 3000

WA:

(08) 9242 5333

ACT:

(02) 6280 4177

Elsewhere: 1800 334 887
email:

[email protected]

Wiring diagram

Part No: F2552

Revision G

Cannon

Summary of Contents for CANTIB

Page 1: ...approved for use with Natural and Propane gases Please leave instructions with the owner INBUILT MODELS CANTIB CANTIBLP CANTIBM CANTIBMLP USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTI...

Page 2: ...ces Installation into a masonry fire place Sealing Gas connection 13 14 Fuel bed and log installation Gas control 15 16 Gas pressure point Gas pressure sdjustment Service instructions 17 General To re...

Page 3: ...accordance with manufacturer s instructions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required inst...

Page 4: ...ains clothing furniture and other flammable mate rials at least 900mm from front and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long as they are restrain...

Page 5: ...nnually to be made by a licensed service per son It is important that circulating air passageways of the appliance be kept clean dirt and lint free for a safe and efficient operation of the heater 12...

Page 6: ...2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refer figure 3 The burner...

Page 7: ...itch for HIGH setting Refer figure 6 7 To turn the burner to LOW setting press switch for LOW setting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the...

Page 8: ...f your heater requires attention contact your supplier or licensed service person listed in this manual Important The appliance should be inspected before use and at least annu ally by an authorised s...

Page 9: ...ropane gas Regulated to supply 2 70 kPa to appliance Fan Three speed Controller Electronic Minimum cavity Height 605mm dimensions dimensions Width 695mm Depth 385mm Power requirement 240 VAC 10 A Opti...

Page 10: ...om sides and front of heater For minimum clearances refer fig 9 and 10 Note Ensure that the combustion air opening under the heater is not obstructed 4 Models CANTIB CANTIBLP should only be installed...

Page 11: ...d 9 Disconnect the switch loom connector from the loom plug 10 To remove the front heater surround undo two s t screws one either side from the bottom flange of the front panel as indi cated in figure...

Page 12: ...efer figure 17a Seal with fibreglass between bottom of heater case and base of fireplace 13 Slide heater into the fireplace ensuring that gas inlet pipe is fed through the hole at the rear bottom RHS...

Page 13: ...bed is retained by a spring clip fixed to the rear of the burner chamber FUEL BED MUST BE HARD UP AGAINST REAR OF BURNER 17 Carefully unpack the log set Logs are numbered as follows No 1 Left front l...

Page 14: ...No 3 log see figure 24 18 Refit the inner glass making sure not to overtighten the screws 19 Refit the front glass surround Ensure that the glass surround is replaced the correct side up The rearward...

Page 15: ...wo pages To check control outlet pressure at burner Full on and Low Flame positions remove the plastic cap from the regulator ad justment location as indicated in figures 27 a b 24 The pressure point...

Page 16: ...for Natural Gas and 1 1 kPa for LPG Turn clock wise to increase pressure and anti clockwise to decrease pressure 27 Switch burners off and remove the manometer tube Tighten pressure test point by tur...

Page 17: ...fixing the fan to the burner chamber underside 3 Replace in reverse order 1 Remove two screws from controller front 2 Disconnect plug 3 Replace in reverse order 1 Follow steps 7 to 11 of the installat...

Page 18: ...roduced Check that spark lead is connected into module Check the continuity of the HT cable Check that there is no short circuit to earth and spark gap is correct Refer figure 31 A positive check is t...

Page 19: ...han 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coils...

Page 20: ...N dis tributor in your state Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Vic Tas 03 9418 5800 NSW 02 9331 8888 SA NT 08 8212 7000 Qld 07 3358 3000 WA 08 9242 5333 ACT 02 6280 4177 Elsewhe...

Reviews: