12
Installation WITHOUT a flue connection.
12
13
13
6. Prepare electrical and gas connections. Remove the lower front cover,
see figure 16. A 10 Amp wall socket needs to be located within 1.5m
of the heater. If using a power point in the chimney, route the plug and
cord through cord access at lower LH side of rear panel.
A grommet is fitted over the cord. Ensure that the grommet is located
over the edges of the access hole. Refer figure 14.
Hard (fixed ) wiring connection is to be carried out only by a qualified
electrician.
7. Remove the front glass surround by holding it firmly on either side and
pulling it towards yourself, see figure 15.
8. Remove the lower front cover by unscrewing two M5 screws through
the air intake slots, see figure 16. If unit is fitted with supply flexible cord
ensure that the cord cannot be trapped when the heater is installed.
9. Disconnect the switch loom connector from the loom plug. Refer figure
17.
10.To remove the front heater surround undo two s/t screws (one either
side) from the bottom flange of the front panel as indicated in figure 18.
Remove the surround by pulling the lower section towards you gently to
partly disengage it from the body of the heater, then gently lift it verti-
cally to completely disengage it. Refer figure 19.
14
15
16
17