10
1. This appliance is to be installed by a licensed service person only.
2. This appliance shall be installed in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, and AS5601 the Australian Stand-
ard for gas installations. Refer also to AS5601 for pipe sizing tables.
3. Remove the heater from the carton and remove the three transit screws.
Check that the heater is suitable for gas available. Refer to the data
label located on the fan chamber base, rear of pedestal front.
(Please dispose of packaging appropriately, keep packaging away
from children).
Clearances
4. Ensure the minimum clearances to combustible construction are main-
tained during installation, including adequate space for the proper
operation and servicing of the heater.
Keep curtains*, furniture and other flammable materials at least 900mm
from front of heater.
* Curtain clearance can be less than 900mm as long as they
are restrained from sides and front of heater.
For minimum clearances refer fig 9 and 10.
Note: Ensure that the combustion air opening under the heater
is not obstructed.
A CLEARANCE OF 50
MM
MUST BE MAINTAINED BETWEEN THE
REAR OF THE CABINET AND THE REAR WALL OF THE FIREPLACE.
Installation into a masonry/brick or mock fireplace.
5. Models CANTIB-NG & CANTIB-LP can be installed onto a masonry/
brick fireplace or mock fireplace. If installing into a mock fireplace a
mock fireplace installation kit MUST be used. The mock fireplace instal-
lation kit can be ordered from the CANNON distributor. Order speci-
fication for the part is ‘MOCKKITRO’.
For installation onto a masonry or brick fireplace WITH a flue connec-
tion refer figure 11. For installation WITHOUT a flue connected refer
figures 12 & 13. After installation of the heater/flue test the flue to
confirm air vents are unobstructed. If an exhaust fan or other heating
appliances are present switch them on. This is to test that there is no
interaction between the CANNON heater and other appliances.
10
9
Installation instructions
15
Gas connection
13. Slide heater into the fireplace ensuring that gas inlet pipe is fed through
the hole at the rear bottom RHS of the heater. Refer figure 22 and gas
connection figure 24.
-
14.With heater in position, flanges should be hard against masonry. Se-
cure case flanges to masonry. Refer figure 23.
15. Connect incoming gas supply pipe to regulator. For inlet position see
figure 24. Close gate over gas supply and seal around the pipe with
fibreglass insulation material. Sealing is important as it prevents leak-
age from fan chamber into chimney: also check for gas soundness.
20
23
22
24