Enter 216 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
8-9-7.
Set Length Scale
Length qualification has to work with the length scale collaboratively. For the reason, three
length variables are available for you to further associate with the desired values. Depending
on the type of qualification you select, length variables can have different meanings. With
Min
length condition,
Code39Len1
variable stands for the minimum size to limit the
minimum length of a valid barcode. On the other hand, with
Min/Max
length condition, the
barcode will be decoded only if its length has to fall within the range of
Code39Len1
to
Code39Len2
.
However,
Code39Len1, Code39Len2,
and
Code39Len3
can also represent a
group of length limits when
Fixed
length qualification is chosen. It means the scanner will
only decode the barcode with the length which agrees with
Code39Len1, Code39Len2,
or
Code39Len3.
3-5
. Set Length2 variable
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
Code39Len1
barcode to determine the value of the length variable.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired number in the range of 0 to 255. For instance, to
set its length to be 8, then scan
8
to assign the specified decimal value “8”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Repeat Steps 2-4 for Code39Len2 and Code39Len3, if necessary.
(6)
Scan
End
barcode to complete the configuration.
*C52E0*
Code39Len1
C52E0
*C53E0*
Code39Len2
C53E0
*C54E0*
Code39Len3
C54E0
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)