Enter 259 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
has to fall within the range of
Matrix25Len1
to
Matrix25Len2
.
In this case,
Matrix25Len1
stands for the minimum and
Matrix25Len2
for the maximum. However,
Matrix25Len1,
Matrix25Len2,
and
Matrix25Len3
can also represent a group of length limits when
Fixed
length qualification is chosen. It means the scanner will only decode the barcode with the
length which agrees with
Matrix25Len1, Matrix25Len2, or Matrix25Len3.
3
-5. Set Length2 variable
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
Matrix25Len1
barcode to determine the value of the length variable.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal
value barcodes representing the desired number in the range of 0 to 255. For
instance, to set its length to be 8, then scan
8
to assign the specified decimal
value “8”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Repeat Steps 2-4 for Matrix25Len2 and Matrix25Len3, if necessary.
(6)
Scan
End
barcode to complete the configuration.
*45501*
Matrix25Len1
45501
*45511*
Matrix25Len2
45511
*45521*
Matrix25Len3
45521
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)
(Length: 1 digit / Range: 0-255)