Enter 253 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
8-19-4.
Transmit Check Digit
Scan the appropriate barcode to determine whether to transmit the check digit.
8-19-5.
Configure Length Qualification
With length qualification the scanner will filter out the inappropriate barcodes whose
lengths are out of range. Scan
Min
barcode to specify the minimum length which the
valid code at least has to be;
Fixed
barcode requires the scanned code length to
necessarily agree with certain fixed number
;
Min/Max
barcode is to confirm whether the
barcode length falls in between maximum and minimum. However, to make this
parameter work effectively, you have to configure the length scale simultaneously. Please
refer to
Section 8-19-7
for more details about configurations of the length scale.
8-19-6.
Set Code ID for Interleave25
A user-defined Code ID functions as an identity for a specific barcode type to be
*44541*
Enable
44541
1
*44540*
Disable
44540
*44530*
Min
44530
*44531*
Fixed
44531
*44532*
Min/Max
44532
*444C2*
French CIP HR
444C2
*444C3*
Case Code
444C3