the calorific capacity and pressure of the gas vary according to the type of gas.
When changing the gas, the technician should successively : change the jets, make the gas connection to the installation and set the
minimum flow of all the gas burner tap.
&+$1*,1*7+(*$67<3(
INSTALLATION
JET
Warning :
Never loosen
the others
screws !
07 GB
To adapt the Hob for use with different types of gas, carry out the
following instructions:
• Remove the grids and burners
• Insert on hexagonal spanner (7 mm) into the burner support
(Figure 2)
• Unscrew the injector and replace it with one suitable for the gas
to be used (see gas type table)
5(*8/$7,1*7+(0,1,080)/$0(
After lighting the burners, turn the control knob to the minimum
setting and then remove the knob (this can easily be removed by
applying gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw
can be adjusted as in Figure 3. Turning the screw clockwise
reduces the gas flow, whilst turning it anticlockwise increases the
flow – Use this adjustment to obtain a flame of approximately 3
to 4 mm in length and then replace the control knob.
When the gas supply available is LPG - the screw to set the idle
flame must be turned (clockwise) to the end stop.
When you have carried out the new gas regulation, replace the
old gas rating plate on your appliance with one (supplied with
hob) suitable for the type of gas for which it has been regulated.
Figure 2