background image

15

15

IMPOR TANT !

The conical pipe fitting must be

used for the United K ingdom only

or if requested by the applicable

local regulations.

If this conical adaptor is not supplied

with the appliance it can be purchased

by contacting the After-S ales S ervice.

Elbow

Gasket

Floating nut

Appliance

inlet

pipe

C onical

pipe

fitting

IS O 228-1 (female)

1/2” G cylindrical

IS O 7-1 (male)

1/2” G conical

Gasket

IS O 228-1 (male)

1/2” G cylindrical

IS O 228-1 (male)

1/2” G cylindrical

R igid pipe

or flexible hose

Fig. 2.1

Gasket

Floating nut

Gasket

Elbow

ISO 228-1 (male) 

1/2” cylindrical

ISO 228-1 (male) 

1/2” cylindrical

Rigid pipe or 

flexible hose

Appliance 

inlet pipe

ADDITIONAL GAS CONNECTION REQUIREMENTS

When connecting the cooktop to the gas supply with rigid pipes or a flexible hose, make 

sure that:
• 

You use rigid pipes or a flexible hose compliant with applicable local regulations. The 

flexible hose shall be of the correct construction for the type of gas being used and of 

the correct size to maintain the heat output of the appliance.

• 

The connection with rigid metal pipes does not cause stress or pressure to the gas 

piping.

• 

The flexible hose is not under tension, twisted, kinked, or too tightly bent, neither while 

the cooktop is in use nor while it is being connected or disconnected.

• 

The flexible hose is not longer than 2000 mm (or refer to applicable local regulations) 

and does not come into contact with sharp edges, corners, or moving parts, as these 

may cause abrasion. Use a single flexible hose only; never connect the cooktop with 

more than one flexible hose.

• 

The flexible hose can easily be inspected along its entire length to check its condition; 

if it has an expiry date, it should be replaced before that date.

• 

If using a flexible hose which is not entirely made of metal, make sure that it does not 

come into contact with any part of the cooktop with a surface temperature of 70°C or 

above (or refer to applicable local regulations).

• 

The rigid pipe or flexible hose is replaced if it shows signs of damage.

• 

The flexible hose is not subject to excessive heat by direct exposure to flue products 

or by contact with hot surfaces.

• 

The socket into which the plug of the flexible hose fit is permanently attached to a firmly 

fixed gas installation pipe and is positioned so that the hose hangs freely downwards.

• 

The  plug  of  the  flexible  hose  is  accessible  after  installation,  so  that  it  can  be 

disconnected for service or removal.

• 

You inform the customer that the rigid pipe or flexible hose should not be subjected to 

corrosion by cleaning agents.

Summary of Contents for CHG6PX SASO

Page 1: ...CANDY HOOVER GROUP S R L Via Comolli 16 20861 Brugherio MB Italy BUILT IN GAS COOKING HOBS INSTALLATION ADVICES INSTRUCTIONS FOR THE USE GB CHG6PX SASO CHG938WPX SASO CHG9WL38WPX SASO...

Page 2: ...2 2...

Page 3: ...Please preserve this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for t...

Page 4: ...people with sensitive skin may have a more pronounced temperature perception with some components although these parts are within the limits allowed by the norms The complete safety of the appliance a...

Page 5: ...e appliance whilst in bare feet If you should decide not to use this appliance any longer or decide to substitute another model before disposing of it it is recommended that it be made inoperative in...

Page 6: ...s and may result in fire NEVER try to extinguish a fire with water but switch off the appliance and then cover flame e g with a lid or a fire blanket WARNING Danger of fire do not store items on the c...

Page 7: ...dance with the wiring rules WARNING The appliance and its accessible parts become hot during use Care should be taken to avoid touching heating elements Children less than 8 years of age shall be kept...

Page 8: ...8 8 ADVICE ADVICE for the for the INSTALLER INSTALLER...

Page 9: ...personal injury or damage This appliance shall only be serviced by authorized personnel Always disconnect the appliance from mains power supply before carrying out any maintenance operations or repai...

Page 10: ...or the thermal protection barrier is not required If the cooktop is installed above an oven the two appliances shall be connected to the gas and or electrical supply with independent connections 90cm...

Page 11: ...9 840 480 60 200 650 mm 500 mm 450 mm E F D G B A C Fig 1 1a Fig 1 1b Cooktop installed G 40 mm Space for connections Clearance Door Thermal protection barrier The thermal protection barrier must be r...

Page 12: ...ful to overlay the junction edges Fasten the brackets F and R to the appropriate socket holes without tightening the screws S for the moment Make sure that the tabs are mounted correctly as shown figs...

Page 13: ...hat they cannot be blocked from either the inside or the outside When these openings cannot be made the necessary air can come from an adjacent room which is ventilated as required as long as it is no...

Page 14: ...viced only by a suitably qualified registered installer The installer shall refer to the local standards in force Failure to install the appliance correctly could invalidate any manufacturer s warrant...

Page 15: ...cooktop is in use nor while it is being connected or disconnected The flexible hose is not longer than 2000 mm or refer to applicable local regulations and does not come into contact with sharp edges...

Page 16: ...NECESSARY FOR GAS COMBUSTION 2 m3 h x kW BURNERS Air necessary for combustion m3 h Auxiliary A 2 00 Semi rapid SR 3 36 Rapid R 6 00 Double ring compact MW 7 00 Double ring DCS 7 00 GAS MAINTENANCE LU...

Page 17: ...eter are marked on the body of each injector REPLACEMENT OF THE INJECTORS OF THE COOKTOP BURNERS To replace the injectors proceed as follows Remove pan supports and burners from the cooktop Using a wr...

Page 18: ...ven with a quick turn from the maximum position to that of minimum The flame adjustment is done in the following way Turn on the burner Turn the tap to the MINIMUM position Take off the knob With a sm...

Page 19: ...with the letter E or the earth symbol or coloured green yellow connect the blue wire to the terminal marked with the letter N or coloured black connect the brown wire to the terminal marked with the l...

Page 20: ...by an authorized service agent in order to avoid a hazard To connect the supply cable Unhook the terminal board cover by inserting a screwdriver into the two hooks A fig 3 1 Open the cable gland by un...

Page 21: ...21 21...

Page 22: ...22 22 ADVICE ADVICE for the for the USERS USERS...

Page 23: ...EATURES AND TECHNICAL DATA 1 1 11 9 8 7 2 3 5 NOTE The knob and symbols may vary Caution Do not cover the hob with aluminium foils Fig 1 2 1 10 9 8 7 2 3 4 10 9 12 8 7 Fig 1 3 6 2 1 3 4 12 7 8 9 10 2...

Page 24: ...system fitted the flow of gas will be stopped if and when the flame should accidentally go out CAUTION If the burner is accidentally extinguished turn the gas off at the control knob and wait at least...

Page 25: ...f liquids To reduce the gas flow to minimum rotate the knob further anti clockwise to point the indicator towards the small flame symbol Other intermediate operating adjustments can be achieved by pos...

Page 26: ...Wait for a few seconds after the gas burner has been lit before letting go of the knob valve activation delay 3 Adjust the gas valve to the desired position If the burner flame should go out for some...

Page 27: ...er 6 cm only for the models with Double ring compact or Double ring burner and with wok pan adapter supplied It is important that the diameter of the pot be suitable to the potentiality of the burner...

Page 28: ...rner depending on models Warning Using woks without this special grille may cause the burner to malfunction Do not use the grille for ordinary flat bottomed saucepans IMPORTANT The special grille for...

Page 29: ...hould be taken around the underneath of the appliance as this area is not designed or intended to be touched and may contain sharp or rough edges that may cause injury ENAMELLED SURFACES All the ename...

Page 30: ...d correctly replaced It is very important to check that the burner flame spreader and the cap have been correctly positioned Failure to do so can cause serious problems Check that the electrode s S fi...

Page 31: ...31 31 S F C T Fig 3 1 Fig 3 2 S T T S Fig 3 3 MODELS WITH DOUBLE RING COMPACT BURNER MODELS WITH DOUBLE RING BURNER Fig 3 4...

Page 32: ...32 32 A B Fig 3 5 Fig 3 6...

Page 33: ...k that the pan supports have been correctly positioned Failure to do so can cause serious problems The prongs of the pan supports must always be centred with the burners fig 3 7 Fig 3 7 Note Continuou...

Page 34: ...34 34...

Page 35: ...35 35...

Page 36: ...naccuracy resulting from printing or transcript errors contained in this brochure We reserve the right to carry out modifications to products as required including the interests of consumption without...

Reviews: