background image

 

 

 

 

 

 

Notices for use 

 

Gentle Breeze

 

 

In the following situation, the indoor unit may blow gentle breeze, and 
the guide louver rotate to a certain position:

 

1. In 

“Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition.

 

2. In 

“Heat” mode, the temperature arrive at the setting value and the compressor stop 

running about 1min.

 

The operating temperature range (outdoor temperature) for cooling unit is 21

~43

℃.

 

for cooling and heating unit is -7

~43

℃.

 

4

 

Working temperature range 

 

Indoor  sideDB/WB(

o

C) 

Outdoor  sideDB/WB(

o

C) 

Maximum cooling 

32/23 

43/26 

Minimum cooling 

21/15 

21/- 

Maximum heating 

27/--- 

24/18 

Minimum heating 

20/--- 

-7/-6 

Summary of Contents for COZY SERIES

Page 1: ...eep it for further reference OWNER S MANUAL MANUAL C H AIR CONDITIONERS Thank you for selecting С H air conditioners Please read this manual carefully before operation and keep it for further reference Split Air Conditioner COZY SERIES MODELS CH S07LH R2 CH S09LH R2 CH S12LH R2 СH S18LH R2 CH S24LH R2 ...

Page 2: ...n with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Do not dispose this product as unsorted municipal waste Collection of such waste separately for spec...

Page 3: ...e about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfunction Keep combustible spray away It can cause afire or explosion Pl...

Page 4: ...long time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shock and malfunction Don t place a space heater near the air conditioner Or CO toxicosis may occur for imcomplete The airflow direction can be adjusted appropriately At operating adjust the vertical air...

Page 5: ... capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the auto defrosting function will act the heat running will stop for 8 10mins During...

Page 6: ...the starting condition 2 In Heat mode the temperature arrive at the setting value and the compressor stop running about 1min The operating temperature range outdoor temperature for cooling unit is 21 43 for cooling and heating unit is 7 43 4 Working temperature range Indoor sideDB WB o C Outdoor sideDB WB o C Maximum cooling 32 23 43 26 Minimum cooling 21 15 21 Maximum heating 27 24 18 Minimum hea...

Page 7: ... out The pattern in displayer Cool Dry Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 6 Wall pipe 5 Guide louver 7 Bind tape 8 Connection 9 Drainage pipe ...

Page 8: ... pressing this key you may select AUTO FAN 1 FAN 2 FAN 3 or FAN 4 and may also cycle between them FAN 4 only in cool or heat mode After being energized AUTO is defaulted Only LOW fan can be set under DRY mode pressing this key can not adjust the fan speed but can send message Fan 1 Fan 2 Fan 3 Fan 4 ON OFF button Press this button the unit will be turned on press it once more the unit will be turn...

Page 9: ...to switch on the unit and cancel the auto switch on When the temperature display becomes constant you may press this key again to display the remaining set time The time value T On and H will display constantly for 2 seconds After 2 seconds the preset temperature will be displayed Within these 2 seconds you may press this key again to cancel the auto switch on and send the message By pressing this...

Page 10: ...le running method and to make ambient comfortable About LOCK Under switch on or switch off state you may hold and key simultaneously to lock and unlock the keypad When locked the display will show the LOCK icon in which case the lock icon will flash three times upon operation of any key After the keypad is unlocked the lock icon on the display will be hidden After being energized the default is un...

Page 11: ...eration should be in its receiving range It should be placed at where is 1m away from the TV set or stereo sound sets If the wireless remote control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Fig 2 Emergency operation If the wireless remote control is lostor broken please use the manual switch button At this time the un...

Page 12: ... angle pull the air filter downward and take it out please see the Fig 4 a b a b Clean the air filter To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can cause deformation or discoloration Never parch it by fire ...

Page 13: ...whether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Clear dust and obstructions from the outdoor unit Repaint the rubiginous place on the outdoor unit to prevent it from spreading Adopt the special shield to cover the outdoor unit avoid the rain water du...

Page 14: ... the smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle the sound is ...

Page 15: ...insert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed If water leakage in outdoor unit When the...

Page 16: ...n the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger that the unit will automatically defrost indoor unit stop blowing air for 3 12min During the defrosting there is water flowing out or vapor be produce...