5
•
Place the Speciality Unit as close as possi-
ble to the pressure tank (well system) or
water meter (city water).
•
Place the Speciality System as close as
possible to a floor drain, or other accepta-
ble drain point (laundry tub, sump, stand-
pipe, etc.).
•
Connect the Speciality System to the main
water supply pipe BEFORE the water heat-
er.
DO NOT RUN HOT WATER
THROUGH THE SPECIALITY SYSTEM
.
Temperature of water passing through the
Speciality System must be less than 100
deg. F.
•
Keep outside faucets on hard water to
save soft water and salt.
•
Do not install the Speciality System in a
place where it could freeze.
Damage
caused by freezing is not covered by
the warranty.
•
Put the Speciality System in a place water
damage is least likely to occur if a leak de-
velops. The manufacturer will not repair or
pay for water damage.
•
A 120 volt electric outlet, to plug the in-
cluded transformer into, is needed within 6
feet of the Speciality System. The trans-
former has an attached 6 foot power ca-
ble.
Be sure the electric outlet and
transformer are in an inside location,
to protect from wet weather.
•
If installing in an outside location, you
must take the steps necessary to assure
the Speciality System, installation plumb-
ing, wiring, etc., are as well protected from
the elements, contamination, vandalism,
etc., as when installed indoors.
•
Keep the Speciality System out of di-
Where To Install The Speciality Unit
Special Unit