Proper Installation
This Speciality system must be properly installed and located in accordance with the
Installation Instructions before it is used.
•
Do not
install or store where it will not be
exposed to temperatures below freezing or
exposed to any type of weather. Water
freezing in the system will break it. Do not
attempt to treat water over 100°F.
•
Do not
install in direct sunlight. Excessive
sun or heat may cause distortion or other
damage to non-metallic parts.
•
Properly ground to conform with all gov-
erning codes and ordinances.
•
Use only
lead-free solder and flux for all
sweat-solder connections, as required by
state and federal codes.
•
Maximum allowable inlet water pressure is
125 psi. If daytime pressure is over 80
psi, night time pressure may exceed the
maximum. Use a pressure reducing valve
to reduce the flow if necessary.
•
Speciality System resins may degrade in
the presence of chlorine above 2 ppm. If
you have chlorine in excess of this
amount, you may experience reduced life
of the resin. In these conditions, you may
wish to consider purchasing a whole house
carbon filter Speciality System system with
a chlorine reducing media.
•
WARNING:
Discard all unused parts and
packaging material after installation. Small
parts remaining after the installation could
be a choke hazard.