background image

10 

 

System Start-Up 

1. Plug  the  power  transformer  into  an  ap-

proved power source.  Connect the power 
cord to the valve. 

2. When power is supplied to the control, the 

screen  will  display  “INITIALIZING  WAIT 

PLEASE” while it finds the service position.

 

3. Manually  step  the  valve  past  the  BRINE 

position  to  the  BACKWASH  position.    If 

screen  is  locked,  press  SETTINGS  for  3 
seconds  to  unlock.    Press  and  hold  the 
MANUL REGEN. Key for 3 seconds.  Press 

any key to skip the BRINE cycle. 

4. Once  in  the  BACKWASH  cycle,  open  the 

inlet on the bypass valve slowly and allow 
water to enter the unit. Allow all air to es-

cape from the unit before turning the wa-
ter  on  fully  then  allow  water  to  run  to 
drain  Backwash  for  30  minutes  to  allow 

the  layers  to  settle  to  their  appropriate 

height.  

5. Press any button to advance to the RINSE 

position.  Check the drain line flow.  Allow 
the  water  to  run  for  3-4  minutes  or  until 
the water is clear. 

6. Press any button to advance to the REFILL 

position.  Check that the valve is filling wa-
ter into the brine tank. Allow the valve to 

refill  for  the  full  amount  of  time  as  dis-
played  on  the  screen  to  insure  a  proper 
brine solution for the next regeneration. 

7. The valve will automatically advance to the 

SERVICE  position.  Open  the  outlet  valve 
on  the  bypass,  then  open  the  nearest 
treated  water  faucet  and  allow  the  water 

to run until clear, close the tap and replace 
the faucet screen. 

8. Add salt into the cabinet / brine tank. 

9.  Program unit. 

Key Pad Configuration 

Start-up Instructions

 

SETTINGS

 

This function is to enter the basic set up infor-
mation required at the time of installation.

 

MANUAL 
REGEN

 

This function is to initiate an immediate or 
delayed manual regeneration.

 

DOWN / 
UP

 

Increase or decrease the value of the settings 
while in the  programming mode.

 

DELAYED REGENERATION 

Press and release the MANUAL REGEN. But-
ton to set a delayed regeneration that will 
occur at the regeneration time.  The main 
display page will show DELAYED REGEN ON.  

To cancel press and release the MANUAL RE-
GEN. Button.  The main display page will 
show DELAYED REGEN OFF. 

IMMEDIATE REGENERATION 

To start an immediate regeneration (or step 
valve through each position), press and hold 
the MANUAL REGEN. Button for 3 seconds 
(until beeps).  The valve will start an immedi-

ate regeneration.  Press any key to skip to 
the next cycle. 

Manual Regeneration (Step / Cycle Valve)

 

SETTINGS 

MANUAL 

REGEN 

UP 

 

DOWN 

 

Summary of Contents for 485DF SIMTAN PLUS Series

Page 1: ...tified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 4 Backwas...

Page 2: ...ing water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize t...

Page 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Page 4: ...itical Service Flow Rate 4 6 gpm 6 8 gpm 8 10 gpm 10 12 gpm Back Wash Flow Rate 2 4 gpm 4 0 gpm 5 0 gpm 7 0 gpm Shipping Weight 141 lbs 158 lbs 198 lbs 244 lbs Hardness Maximum 45 gpg Iron Maximum 15...

Page 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Page 6: ...d experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be avoided Cleaning chemic...

Page 7: ...is decreased in the brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to si...

Page 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Page 9: ...9 Installation...

Page 10: ...ayed on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the bypass then open the nearest...

Page 11: ...r if the water source is not clean 1NUT turbidity The system will back wash every time REGEN TIME This setting determines the time of day to perform a scheduled regeneration REGEN DAYS This value is t...

Page 12: ...System operates The regeneration cy cle lasts up to 180 minutes During this time you may hear water running intermittently to About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Page 13: ...ration Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and...

Page 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Page 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Page 16: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Page 17: ...17...

Page 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your Speciality System to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE a...

Page 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 21: ...21 Control Valve Exploded View...

Page 22: ...22 Control Parts List...

Page 23: ...44 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 60010005 OVER FLOW FITTING ASSEMBLY G 1 55010023...

Page 24: ...24 Need to fill with something...

Page 25: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Page 26: ...Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times op...

Page 27: ...27...