Manual Bypass

 

In  the  case  of  emergency,  such  as  an  overflowing  brine  tank,  you  can  isolate  your  water 

Speciality System from the water supply using the bypass valve located at the back of the 
control. In normal operation the bypass is open with the on/off knobs in line with the inlet 
and outlet pipes. 
 

To  isolate  the  Speciality  System,  simply  rotate  the  knobs  clockwise  (as  indicated  by  the 
word BYPASS and arrow) until they lock. You can use your water related fixtures and appli-
ances as the water supply is bypassing the Speciality System. However, the water you use 

will be hard. To resume soft water service, open bypass valve by rotating the knobs coun-

Maintenance 

Adding Salt

 

Use only NUGGET or PELLET water Speciality System salt.  Check the salt level monthly.  

It 

is important to maintain the salt level above the water level. 

 To add salt, simply lift 

the salt lid and add the salt directly into the brine tank.  Be sure the brine well cover is on 
and fill only to the height of the brine well. 

Bridging

 

Humidity or wrong type of salt may create a cavity between the water and the salt. This ac-

tion, known as “bridging”, prevents the brine solution from being made, leading to your wa-

ter supply being hard. 
 
If you suspect salt bridging, carefully pound on the outside of the brine tank or pour some 

warm water over the salt to break up the bridge.  This should always be followed up by al-
lowing  the  unit  to  use  up  any  remaining  salt  and  then  thoroughly  cleaning  out  the  brine 
tank.  Allow two hours to produce a brine solution, then manually regenerate the Speciality 

OPEN

 

CLOSED

 

Summary of Contents for 485DF SIMTAN PLUS Series

Page 1: ...tified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system 4 Backwas...

Page 2: ...ing water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize t...

Page 3: ...ly lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pre...

Page 4: ...itical Service Flow Rate 4 6 gpm 6 8 gpm 8 10 gpm 10 12 gpm Back Wash Flow Rate 2 4 gpm 4 0 gpm 5 0 gpm 7 0 gpm Shipping Weight 141 lbs 158 lbs 198 lbs 244 lbs Hardness Maximum 45 gpg Iron Maximum 15...

Page 5: ...e Damage caused by freezing is not covered by the warranty Put the Speciality System in a place water damage is least likely to occur if a leak de velops The manufacturer will not repair or pay for wa...

Page 6: ...d experience breakthrough for Iron Mn or Tannins To be safe choose one size larger when sizing Any oxidative pre treatment such as air or chemicals is unnecessary and should be avoided Cleaning chemic...

Page 7: ...is decreased in the brine tank When the water in the brine tank has been drawn into the mineral tank 10 15 minutes unplug the valve 5 Turn the bypass handles to the bypass mode 6 Allow the unit to si...

Page 8: ...alve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub...

Page 9: ...9 Installation...

Page 10: ...ayed on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE position Open the outlet valve on the bypass then open the nearest...

Page 11: ...r if the water source is not clean 1NUT turbidity The system will back wash every time REGEN TIME This setting determines the time of day to perform a scheduled regeneration REGEN DAYS This value is t...

Page 12: ...System operates The regeneration cy cle lasts up to 180 minutes During this time you may hear water running intermittently to About The System PARAMETER DESCRIPTION JULY 17 2012 8 30 PM TOTAL 1 500 G...

Page 13: ...ration Step Name Description 1 Back Wash Fresh water is introduced to the bottom of the tank flowing upwards expanding the ion exchange resin to rinse out any dirt or small particles to the drain and...

Page 14: ...ly NUGGET or PELLET water Speciality System salt Check the salt level monthly It is important to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt dir...

Page 15: ...the control valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriv...

Page 16: ...antity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP...

Page 17: ...17...

Page 18: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 19: ...m clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your Speciality System to freezing or to temperatures above 100 F Resin Cleaner DO NOT USE a...

Page 20: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 21: ...21 Control Valve Exploded View...

Page 22: ...22 Control Parts List...

Page 23: ...44 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 60010005 OVER FLOW FITTING ASSEMBLY G 1 55010023...

Page 24: ...24 Need to fill with something...

Page 25: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Page 26: ...Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times op...

Page 27: ...27...

Reviews: