PROBLEM
EXCESSIVE PRESSURE LOSS
Peak or continuous service flow rate may be exceeding capacity
causing the unit to be restrictive due to size.
1.
Check unit specifications to ensure proper sizing for the application.
2.
Degradation of resin due to chlorine or chloramine.
.
Replace the resin bed.
HALL SENSOR - ERROR CODE
Power surge.
Unit is in normal home position showing ‘Hall Sensor Error’.
1.
Unplug for one (1) minute.
2.
Plugin.
3.
Initiate Manual Regen if the error reoccurs .
Circuit failure.
Transformer or motor failure – unit will NOT be in the home position; water may be
running at the drain.
1.
Replace the motor and transformer if unable to determine the output of the
transformer separately.
2.
Contact your authorized installer for parts and or assistance.