PRESS SETTINGS KEY

3 SEC TO UNLOCK

1.

  

Press any button to start. The display 

may read 

PRESS SETTINGS KEY 3 

SEC TO UNLOCK

 if left untouched for 

several minutes.

2.

  

To unlock, press 

button one (1

) and 

hold for three (3)seconds. The display 

will beep confirming unlock.

JAN/09/2023 

12:15AM

MANUAL REGEN 

U1 IMMEDIATELY

3.

  

Press and hold

 button two (2

) to 

start Manual Regeneration process. 

U1 BACKWASH 

10:00 REMAIN

6.

  

For Upflow valve 

press button two 

(2

) to manually advance to backwash 

position. Downflow valves will 

automatically start in backwash position.

4.

  

Press 

button three (3) or four (4

), 

choose 

U1 

or

 U2

.

5.

  

Press 

button two (2

) to start a 

regeneration cycle.

MANDATORY

Be sure to open the bypass inlet very slowly. Do 

NOT FULLY open the bypass inlet until there is a 

steady stream of water at the drain as this will 

result in media being expelled from the unit

START-UP INSTRUCTIONS

Now that your water softener is plumbed into position it is time to start up and program the unit.

STEP 1. ADD WATER TO BRINE TANK

1.

  Open the brine tank  salt lid and fill with water until there is approximately 1” [25.4 mm] of water above  

 

the grid plate.

2.

  If there is no grid plate, fill the tank with 3” [75 mm] of water. 

Do NOT add salt to the brine tank at this time.

 

 

NOTE

If severe loss in water pressure is ob-

served when the softener unit is initially 

placed in service, the softener tank may 

have been laid on its side during transit. 

If this occurs, backwash the softener to 

‘reclassify’ the media.

STEP 2. PURGE AIR FROM  THE UNIT

7.

   Open the bypass inlet very slowly

 until there is a steady stream of  

 

  water at the drain. Opening the bypass inlet too quickly could result in    

  resin being expelled from the unit and into the plumbing lines. With the    

  valve in the backwash position the unit will purge air from the system,    

  sending it to the drain.

8.

  With the bypass inlet now fully open, let the system run until all the air is purged 

  and there is a steady stream of water at the drain.

9.

  Repeat steps two (2) to six (6) to purge the U2 tank of air. Press button two (2) to advance to the refill position and allow the unit to refill  

  the brine tank to 1” [25.4 mm] above the grid board – this may require manually advancing the unit through its cycles more than once.  

  Alternatively, you can press and hold button 2 (two) to advance to the service position and manually add the required amount of water  

  as described in step 1.

10.

 Allow the unit to return to the SERVICE position. 

11.

 Slowly open the bypass OUTLET knob until fully open.

Summary of Contents for 85TA

Page 1: ...operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is microbiologica...

Page 2: ...WORKS 6 FEED WATER PARAMETERS 6 UNPACKING INSPECTION 7 BEFORE INSTALLATION 8 PREPARATIONS 9 PLANNING YOUR INSTALLATION 12 INSTALLATION STEPS 14 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION 16 START UP I...

Page 3: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Page 4: ...umber serial number and valve serial number in the Records Contacts section as they will be important if you need to troubleshoot FIND AND RECORD VALVE TYPE SERIAL NUMBERS RECORDS CONTACTS YOUR DEALER...

Page 5: ...or 40 F 110 F Do NOT expose softener to freezing temperatures or vacuum Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct su...

Page 6: ...lease the sodium and exchange them with the hardness ions The resin beads and the softener must be regenerated as these ions are exchanged and are used up Regeneration is accomplished by rinsing the r...

Page 7: ...ON CONTINUED WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after installation Small parts could be a choking hazard NOTE Canature is NOT responsible for damages in transit...

Page 8: ...to the pipe as excessive heat can damage them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience...

Page 9: ...der part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles c...

Page 10: ...ove the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Page 11: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Page 12: ...to a floor or laundry tub drain and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valv...

Page 13: ...ail Drain Elbow Assembly T connection 3 8 BrineTube 5 8 Drain Line 5 8 Overflow Line Optional Floor Drain Optional Pipes Fixed Structure BrineValve Connector Detail Laundry Drain AC 120V 10A Current P...

Page 14: ...plied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clips 5 Connect the inlet and outlet of the water softener to the...

Page 15: ...lease make sure bypass knobs are completely open otherwise the untreated water may enter through the valve SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEPS CONTINUED 7 Attach the brine line...

Page 16: ...press and hold the MANUAL REGEN key the value changes to zero PARAMETER DESCRIPTION JULY 17 2023 8 30 PM Month Day Year Time U1 ONLINETOTAL 1500 GAL The current status of Unit 1 ONLINE or STANDBY The...

Page 17: ...grid plate fill the tank with 3 75 mm of water Do NOT add salt to the brine tank at this time NOTE If severe loss in water pressure is ob served when the softener unit is initially placed in service t...

Page 18: ...ganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these numbe...

Page 19: ...on one 1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETT...

Page 20: ...rollers will operate with one tank in service and the second tank off line for regeneration or ready in standby Based on peak flow water usage the trip points can be set accordingly EXAMPLE U5T30S D3T...

Page 21: ...hen it regenerates Salt Water Congratulations Start Up Instructions are now complete the unit is operational NOTE See Problem Water Injector Kit if you have iron in your water and are installing an up...

Page 22: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Page 23: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Page 24: ...s happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring the me...

Page 25: ...sy Feeder for proper operation A ResCare Easy Feeder is essential if your raw water contains measurable amounts of Iron 2 Mark the location of the holder and drill 1 Measure 2 inches from the top of t...

Page 26: ...tle 45128 Rust Out 50 lb Pail USA only Item Description 55030005 Easy Feeder 0 5 oz day Feeder 55030006 Easy Feeder 1 0 oz day Feeder 55030007 Easy Feeder Starter Kit oz with 64 oz ResCare SERVICING Y...

Page 27: ...shown Place spacer in then a seal and repeat until finishing with a seal 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston Assembly Remove 3 X Screws Plat...

Page 28: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Page 29: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Page 30: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Page 31: ...ed HALL SENSOR ERROR CODE Power surge Unit is in normal home position showing Hall Sensor Error 1 Unplug for one 1 minute 2 Plugin 3 Initiate Manual Regen if the error reoccurs Circuit failure Transfo...

Page 32: ...fiberglass tank has a tripod base it must have been properly and securely attached to the floor If not done or improperly installed the tank warranty will be void At our sole discretion we will repai...

Reviews: