Section 2 ‒ Operation and Installation

 

 

MLMux4 User's Guide   

 

 

 

 

 

 

    

       

 

  

 

2.3 Input Protection

 

The MLMux4 is equipped with lightning protection components on the control signals. As a result, care must be 
exercised in the installation to maximize their effectiveness. Specifically, an effective earth ground must be attached 
to the MLMux4 shield (S) for proper protection. Most vibrating wire instruments also have lightning protection 
components. 

The Enable and Clock inputs can be connected to 12 volts directly without damaging the MLMux4. The connections 
to the MLRemote module or datalogger should be disconnected and insulated from contacting other electrical 
connections.  

Hint - The MLRemote module comes in two different power options. One option is a 6V alkaline battery pack and the second 
option is a 12V lithium battery pack. 

The 12V tolerant inputs allow the MLMux4 to be field tested without the need for a datalogger connection. The 
enable can be wired to the 12V input while the clock input can be carefully touched to 12V. This action will cause the 
MLMux4 to step channels for each touch to 12 volts. 

 

 

Summary of Contents for MLMux4

Page 1: ...MLMux4 User s Guide Initial Release February 2022...

Page 2: ...o warranty as to the suitability of this information and or products for any given application or use Warranty Policy Canary Systems warrants products manufactured by Canary Systems excepting software...

Page 3: ...ppliers specifically disclaim any express or implied warranty of fitness for High Risk Activities Documentation and Release Notes To obtain the most recent version of all Canary Systems technical docu...

Page 4: ...ur technical documentation and user s guides at https canarysystems com support users guides The following documents contain information that may be useful throughout the course of this manual MLWebHa...

Page 5: ...6 1 2 Specifications 6 Section 2 Operation and Installation 7 2 1 Operation Details 7 2 2 Enclosure Installation 8 2 3 Input Protection 9 2 4 Controller Connections 10 2 5 Instrument Connection 11 2...

Page 6: ...e of at least 40 C to 85 C The use of low contact resistance relays means almost universal instrument support a degree of lightning protection on the control lines and virtually infinite channel isola...

Page 7: ...l In the case of a single control line only the Clock terminal is used The Enable signal is not required and the Enable terminal must remain unconnected The device control differs only in the increase...

Page 8: ...er s Guide 2 2 Enclosure Installation The MLMux4 can be mounted to any surface with 4 6 32 mounting screws Hint The MLMux4 comes pre installed when ordered with the MLRemote The placement of the mount...

Page 9: ...ck inputs can be connected to 12 volts directly without damaging the MLMux4 The connections to the MLRemote module or datalogger should be disconnected and insulated from contacting other electrical c...

Page 10: ...cription H1 H1 High side of CH1 L1 L1 Low side of CH1 H2 Not Used High side of CH2 L2 Not Used Low side of CH2 S S Cable Shield PWR PWR 12V Power GND GND Ground EN EN Enable CLK CLK Clock The figure b...

Page 11: ...ecting Vibrating Wire Instruments to the MLMux4 Each VW sensor typically has four wires and a shield The wires are inserted into the terminal on the MLMux4 Record the serial number of the sensor so th...

Page 12: ...ss MLWebHardware and configuring new device programs 1 Select CAN MLMux4 as the Mux Type on the Multiplexer form 2 Select either 4 4wires or 8 2 wires from the Channels dropdown This should match the...

Page 13: ...s Guide 13 Section 3 Troubleshooting 3 1 Troubleshooting Flowchart If you cannot obtain readings using the MLMux4 or the readings are unstable then see the troubleshooting flowchart below for help in...

Reviews: