background image

 

Section 1 ‒ Introduction

 

 

 

 

 

 

 

 

 

    

       

 

MLMux4 User's Guide   

 

Section 1 ‒ Introduction 

 

1.1 Overview

 

The Canary Systems

©

 MLMux4 expands the number of instruments that may be read by a compatible Automatic 

Data Acquisition System (ADAS). It supports two switching modes, 4-channels by four wire, or 8-channels by two 
wire. A switch on the face of the module configures the switching between 4/8 channel mode.  

The MLMux4 utilizes advanced high-reliability components such as industrial grade screw clamp terminal blocks, 
solid state relays and a flash microcontroller from Microchip Devices to help ensure years of reliable and trouble-free 
operation in most environments (components are rated to standard long term temp range of at least -40°C to 
+85°C). The use of low contact resistance relays means almost universal instrument support, a degree of lightning 
protection on the control lines, and virtually infinite channel isolation. 

A view of the MLMux4 is shown below.  

 

Warranty for the MLMux4 is applicable for one year from the date of shipment. The warranty does not cover failure 
by improper installation, misuse, or by nature including, but not limited to; flood, lightning, fire, or other catastrophe. 
Should you encounter problems with your MLMux4, contact Canary Systems at the address listed in the front of this 
manual. 

 

1.2 Specifications

 

General

 

Power requirements: 4-20 VDC

 

 

Active Current with one Channel Active: 2mA @ 12VDC 
Standby Current: 1.2mA @ 12VDC 
Quiescent Current: 0.6 

µA

 

Control Line Input Levels: 3.3 - 12V (16V Max)

 

Contact Resistance: 0.8 Ω 
Maximum Switched Current: 2.5 A @60 VCD 
Operating temperature: -40 to +85° C (-40 to +185° F) 
 

 

 

Summary of Contents for MLMux4

Page 1: ...MLMux4 User s Guide Initial Release February 2022...

Page 2: ...o warranty as to the suitability of this information and or products for any given application or use Warranty Policy Canary Systems warrants products manufactured by Canary Systems excepting software...

Page 3: ...ppliers specifically disclaim any express or implied warranty of fitness for High Risk Activities Documentation and Release Notes To obtain the most recent version of all Canary Systems technical docu...

Page 4: ...ur technical documentation and user s guides at https canarysystems com support users guides The following documents contain information that may be useful throughout the course of this manual MLWebHa...

Page 5: ...6 1 2 Specifications 6 Section 2 Operation and Installation 7 2 1 Operation Details 7 2 2 Enclosure Installation 8 2 3 Input Protection 9 2 4 Controller Connections 10 2 5 Instrument Connection 11 2...

Page 6: ...e of at least 40 C to 85 C The use of low contact resistance relays means almost universal instrument support a degree of lightning protection on the control lines and virtually infinite channel isola...

Page 7: ...l In the case of a single control line only the Clock terminal is used The Enable signal is not required and the Enable terminal must remain unconnected The device control differs only in the increase...

Page 8: ...er s Guide 2 2 Enclosure Installation The MLMux4 can be mounted to any surface with 4 6 32 mounting screws Hint The MLMux4 comes pre installed when ordered with the MLRemote The placement of the mount...

Page 9: ...ck inputs can be connected to 12 volts directly without damaging the MLMux4 The connections to the MLRemote module or datalogger should be disconnected and insulated from contacting other electrical c...

Page 10: ...cription H1 H1 High side of CH1 L1 L1 Low side of CH1 H2 Not Used High side of CH2 L2 Not Used Low side of CH2 S S Cable Shield PWR PWR 12V Power GND GND Ground EN EN Enable CLK CLK Clock The figure b...

Page 11: ...ecting Vibrating Wire Instruments to the MLMux4 Each VW sensor typically has four wires and a shield The wires are inserted into the terminal on the MLMux4 Record the serial number of the sensor so th...

Page 12: ...ss MLWebHardware and configuring new device programs 1 Select CAN MLMux4 as the Mux Type on the Multiplexer form 2 Select either 4 4wires or 8 2 wires from the Channels dropdown This should match the...

Page 13: ...s Guide 13 Section 3 Troubleshooting 3 1 Troubleshooting Flowchart If you cannot obtain readings using the MLMux4 or the readings are unstable then see the troubleshooting flowchart below for help in...