Canaan AvalonMiner1246 User Manual Download Page 9

board is not on, it is necessary to replace the MM control board.

If the MM control board LED is on but the fan does not rotate, check
the fan connection line or replace the fan.

Can’t mine

1、Faulty phenomenon

Unable to connect the pool for a long time (more than 5 minutes)
after starting up (the miner lights up yellow for a long time, does
not turn green light, has no hashrate).

The miner pool can be connected after the machine is turned on (the
LED light of the miner is green), but it has no hashrate.

2、Possible cause

pool configuration error.

Network configuration error.

The miner cannot access the Internet.

The miner power supply has no main circuit output (wiring error,
overload, short circuit or damage).

The miner's hashboard does not work。

overheat protection.

3、Check and repair

If the PC cannot be connected to the miner through the network, you
can try to restore the factory settings after confirming that the
network environment is normal, the network cable is firmly connected,
and the miner is started normally. The method of restoring factory
settings is shown in Appendix I.

Check the current firmware version of mining machinery, and it is
recommended to update it to the latest version with FMS. See Appendix
3 for the upgrade method.

Check the status of the hashboard .

Click log to view the working status as shown in the figure below. It
should be in work normally. If it is overheating shutdown, check the
fan and ambient temperature as follows.

Check the number of hash boards shown in the figure below. If the
value is 1 or 2, you need to contact our after-sales personnel for
handling. If it is 0, you need to check the status of the power
supply according to the following.

Summary of Contents for AvalonMiner1246

Page 1: ...y please install and use in strict accordance with the instructions Do not transform the equipment or replace the parts by yourself Do not use power supply beyond rated voltage range Do not place equipment in unstable places When checking and repairing the equipment please entrust professional personnel to operate When the equipment is abnormal cut off the power supply quickly and contact the afte...

Page 2: ...he 4Pin fan extension cable 4 is connecting the power supply with the control board and connecting it with 6pin cable as shown in the following figure 5 is to connect the hash board with the control board with 2 7pin cable as shown below ...

Page 3: ...n LED Button RESET System reset button system reset will not affect the network series FUNC Function button can be used to restore factory configuration enter configuration mode switch on light status during operation etc ...

Page 4: ...de and configuration mode The default mode is DHCP mode Normal mode In normal operation mode the device runs in this mode most of the life cycle In this mode the network can use DHCP dynamic acquisition or static IP and the factory setting is DHCP Configuration mode Enter this mode by press the func button during the Red LED light at second time about 3 seconds at miner start up Press the func key...

Page 5: ...reboot on the left side of the console or manually power off and restart Don t forget to switch the network connection so that the device can t access the Internet Use the browser to access the modified IP address again If the indicator is green the operation is correct System setting Access the built in web service of the device through the browser and access the device console after login User l...

Page 6: ...e following figure shows the factory default settings Normal mode normal mode low power consumption mode or high performance high power consumption mode can be selected for work mode When using high performance mode please pay attention to using the power supply with higher power output to avoid damaging the hardware Note after saving the configuration of the ore pool it must be restarted You can ...

Page 7: ...r contact customer service The firmware of the device can be upgraded by FMS software Restore to factory setting When power on press the func key for 5 to 10 seconds and the system will automatically clear the saved configuration including network mine pool password and other information After the configuration is cleared the white indicator light flashes frequently indicating that the configurati...

Page 8: ...rsion The circuit board is damp and corroded beyond the warranty period If the above situation happens unfortunately we can still provide charge maintenance service for your equipment you can also contact the after sales personnel to purchase parts for self repair Malfunction Boot failure 1 Failure phenomenon Fan does not turn or LED light does not light up after starting 2 Possible Cause Mine fan...

Page 9: ... overheat protection 3 Check and repair If the PC cannot be connected to the miner through the network you can try to restore the factory settings after confirming that the network environment is normal the network cable is firmly connected and the miner is started normally The method of restoring factory settings is shown in Appendix I Check the current firmware version of mining machinery and it...

Page 10: ...onnection with the pool is currently disconnected and has not been restored usually because the server at the end of the pool is disconnected due to excessive pressure if it occurs frequently for a long time other mining pools can be replaced SYSTEMSTATU The current working status is recorded It is in work normally Among them hash board is the number of hash boards in operation If it is 1 or 2 you...

Page 11: ...figuration of mine pool miner and miner is correct In the background of the mining machine click pool on the left column to check the configuration of pool worker and password Finally click the Save button to save the settings restart the machine and the configuration takes effect 4 Check network setting Click Network on the left The default configuration is DHCP mode If all the data here is empty...

Page 12: ...Miner Simple Makeup 1 The assembled hash boards case shell and rear panel are assembled as follows ...

Page 13: ...2 Place the chassis vertically push the three hash board onto the guide rail of the chassis and pay attention to the assembly direction of the hash board components as shown in the figure ...

Page 14: ...3 Assemble the hashboards in place as shown in the figure 4 Assemble the rear panel to the chassis pay attention to the assembly direction as shown in the figure ...

Page 15: ...e power supply with the hook position of the power support press it to level and push the power supply horizontally according to the arrow direction in the figure until the snap pops up with a click sound indicating that the power supply is assembled in place ...

Page 16: ...e and pay attention to the position of locating pin 8 As shown in the figure place the conductive aluminum bar positive pole at the position shown in the figure first assemble the set screw but do not tighten it tighten other screws and finally tighten the set screw ...

Page 17: ...9 Connect the fan extension cable with MM board pay attention to the connection sequence 10 As shown in the figure place the conductive aluminum bar negative Set screw 1 1 2 2 ...

Page 18: ...semble the set screw but do not tighten it tighten other screws and finally tighten the set screw 11 Connect the voltage regulating line of the power supply to the MM board and connect the plug of the temperature sensing line to the MM board Set Screw ...

Page 19: ...12 Hash as shown in the assembly diagram 13 Place the upper shell and fix it with flat head screw as shown in the figure ...

Page 20: ...14 Assemble the fan line in sequence as shown in the figure ...

Page 21: ...Upper FAN Below FAN Below FAN Upper FAN ...

Page 22: ...on and release Note that you need to keep the func key pressed all the time Keep func pressed until the miner s red LED flashes Appendix 2 firmware version viewing method view version in the background Click overview on the left column to see the firmware version number in the figure below view with FMS Directly view the contents of ver in the far right column of the mine machine list in FMS Appen...

Page 23: ...In the pop up dialog box select the firmware file to be upgraded AUP and click open As shown in the figure below There will be progress prompts during the update process ...

Page 24: ...ion number of miner firmware DNA The Unique miner ID NETFAIL After connecting the pool successfully the time to disconnect from the mine pool and the time to resume the connection are also included The odd number items items 1 3 and 5 are the time of disconnection from the pool and the even number items items 2 4 and 6 are the time for resuming the connection with the pool The time is in seconds a...

Page 25: ...o the output voltage of the power supply Item 5 the output power of the power supply to the hash board the normal value is between 3000 and 3200 Item 6 the desired output voltage of the power supply to the force calculation board which is configured by the control board If the six parameters in the PS field of the power supply are all 0 it means that the control board cannot communicate with the p...

Page 26: ...ed to find a specific one among many miners use API to light up the yellow green flashing LED light of the miner Here is the status of whether the yellow and green flashing LED is on 1 indicates that it is on 0 means it is not MGHS The calculation force of a single force plate unit GH S MTmax Maximum chip temperature in a single hashboard MTavg Average chip temperature in a single hashboard TA ASI...

Page 27: ...ime 1s Approximately 20 30s Long time 2 LED Status Description LED status Description Off state The firmware is not running no power input possible Red LED light The system enters test mode or to restore the status after the factory setting operation it is necessary to release the func key and restart to make the master control enter the normal working state Yellow LED light The system has been st...

Reviews: