There will be a prompt at the end of the update. If all are successful, A12
upgrades were successful. Otherwise, all IP addresses that failed to
upgrade will be listed. For the miner that failed to upgrade, you can
select them according to IP, click the button
to restart them, wait
for 3 minutes, and then try to upgrade these mining machines again.
Appendix 4 description of main parameters of log page
field
Name
Remark
Elapsed
Total running time of miner after
starting (unit: s)
Ver
Version number of miner firmware
DNA
The Unique miner ID。
NETFAIL
After
connecting
the
pool
successfully,
the
time
to
disconnect from the mine pool and
the time to resume the connection
are also included.
The
odd
number
items
(items 1, 3 and 5) are
the time of disconnection
from the
pool, and the
even number items (items
2, 4 and 6) are the time
for
resuming
the
connection with the pool.
The time is in seconds,
and the starting time of
miner is the 0 second.
SYSTEMSTATU The current status of the system,
including the working status and
the
number
of
hash
boards
in
operation。
DH
Average calculation error rate.
The normal value was 0.6-1.6%.
Temp
Ambient temperature
TMax