CBP-436(2017) Operation and Maintenance Manual-CTS Tractors
Camso | 12-17 | 26
4. Connect the hydraulic
power source to track
tensioning hose.
Note: Track tensioning hose is
supplied with your new track
system. Replacement track
tensioning hose available for
purchase from your
dealer/distributor.
Note: Be sure that the hose connected from the hydraulic power source and the track
tension system is completely filled with oil prior to tensioning the track system. Failure to
purge air from hose will cause air to be trapped in the track tensioning system and may
result in correct track tension pressure not being maintained during use.
5. Connect the hose to the
tensioning system.
6. Activate hydraulic power
source to pressurize track
tensioning hose.
7. Slowly open the track
tensioning valve until the
pressure starts to rise. Allow
track tension pressure to
reach 1000 psi ± 50 psi (70 ±
3.5 bar) pressure. Once
1000 psi ± 50 psi (70 ± 3.5
bar) pressure is reached,
close the track tensioning
valve.