Section 5. Programming the Datalogger
5-14
First Command Option (Parameter 5)
Output mode
| String number or termination character
| | | |
x x x x
Output Mode:
0
No output format string
1
Convert location to ASCII floating point. Add character/delimiter between
values if enabled. The last value will not have a delimiter after it.
2
Convert location to ASCII hex pair. Add character/delimiter between values
if enabled. The last value will not have a delimiter after it.
3
Convert location to 8-bit binary. Add character/delimiter between values if
enabled. The last value will not have a delimiter after it.
4
Convert location to 16-bit binary. Add character/delimiter between values if
enabled. The last value will not have a delimiter after it.
8
Transmit a user-defined string 0-255 or fixed string 256-511.
9
String type formatter; this is used where input; location data is to be
transmitted in a complex format. See Output Formats in Section 3.
String Number or Delimiter Character:
If output mode 9 is chosen this is the string number 0..255. If the string is not
allocated then the formatter will not operate. If mode 8 is chosen, then this is
the user defined string 0-255 or fixed string 256-511. If output modes 1 to 4 are
chosen, then this specifies the delimiter character as an ASCII code 0..255. 999
means character not enabled.
Second Command Option (Parameter 6)
This is used for filter set-up if data is expected back after output.
Input mode
| String number or character/delimiter code
| | | |
x x x x
Input Mode:
0
No filter
1
Convert any ASCII numbers to Campbell Scientific floating point up to the
termination character if set
2
Convert any ASCII hex pair to Campbell Scientific floating point up to the
termination character if set
3
Convert 8-bit binary number to Campbell Scientific floating point up to the
termination character if set
4
Convert 16-bit binary number to Campbell Scientific floating point up to the
termination character if set.
8
Transmit a user-defined string 0-255 or fixed string 256-511
9
String filter type. See Filter Strings in section 3.
String Number or Character Code
If input mode 9 is chosen, this is the user-defined filter string number 0..255 or
fixed filter string 256..511 used for the filter; if the string is not allocated the
filter will not operate. If input mode 8 is chosen, this number is the defined
string 0-255 or fixed string 256-511. If input modes 1 to 4 are chosen, this is
Summary of Contents for SDM-SIO4
Page 6: ...SDM SIO4 Table of Contents iv This is a blank page ...
Page 12: ...Section 1 Introduction 1 6 This is a blank page ...
Page 16: ...Section 2 Installation and Hardware Set Up 2 4 This is a blank page ...
Page 26: ...Section 3 Understanding How the SDM SIO4 Handles Data 3 10 This is a blank page ...
Page 32: ...Section 4 Programming the SDM SIO4 4 6 This is a blank page ...
Page 62: ...Section 5 Programming the Datalogger 5 30 This is a blank page ...
Page 76: ...This is a blank page ...
Page 81: ...This is a blank page ...