CS210 Enclosure Humidity Sensor
Example 4. Sample 21X Program
;{21X}
;
*Table 1 Program
01: 10
Execution
Interval
(seconds)
1: Batt Voltage (P10)
1: 1
Loc [ Batt_Volt ]
2: Panel Temperature (P17)
1: 2
Loc [ PnlTempC ]
;Turn the CS210 on and leave it on.
;The CS210 needs approximately 10 seconds to stabilize. First scan will be low.
3: Do (P86)
1: 41
Set Port 1 High
4: Volt (SE) (P1)
1: 1
Reps
2: 15
5000 mV Fast Range
3: 1
SE
Channel
4: 3
Loc [ Enc_RH ]
5: 0.1
Multiplier
6: 0
Offset
5: If time is (P92)
1: 0
Minutes
into
a
2: 1440
Minute
Interval
3: 10
Set Output Flag High
6: Set Active Storage Area (P80)
1: 1
Final
Storage
2: 100
Array
ID
7: Real Time (P77)
1: 1220
Year,Day,Hour/Minute (midnight = 2400)
8: Minimum (P74)
1: 1
Reps
2: 0
Value
Only
3: 1
Loc [ Batt_Volt ]
9: Minimum (P74)
1: 1
Reps
2: 0
Value
Only
3: 2
Loc [ PnlTempC ]
10: Maximum (P73)
1: 1
Reps
2: 0
Value
Only
3: 2
Loc [ PnlTempC ]