background image

Warranty and Assistance 

The

 

CS210 ENCLOSURE RELATIVE HUMIDITY SENSOR 

is warranted 

by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and 
workmanship under normal use and service for twelve (12) months from date 
of shipment unless specified otherwise.  Batteries have no warranty.  
CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to 
repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective 
products.  The customer shall assume all costs of removing, reinstalling, and 
shipping defective products to CAMPBELL SCIENTIFIC, INC.  CAMPBELL 
SCIENTIFIC, INC. will return such products by surface carrier prepaid.  This 
warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products 
which have been subjected to modification, misuse, neglect, accidents of 
nature, or shipping damage.  This warranty is in lieu of all other warranties, 
expressed or implied, including warranties of merchantability or fitness for a 
particular purpose.  CAMPBELL SCIENTIFIC, INC. is not liable for special, 
indirect, incidental, or consequential damages. 

Products may not be returned without prior authorization.  The following 
contact information is for US and International customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 
www.campbellsci.com to determine which Campbell Scientific company 
serves your country.  To obtain a Returned Materials Authorization (RMA), 
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342.  After an 
applications engineer determines the nature of the problem, an RMA number 
will be issued.  Please write this number clearly on the outside of the shipping 
container.  CAMPBELL SCIENTIFIC's shipping address is: 

 

 

CAMPBELL SCIENTIFIC, INC. 

 RMA#_____ 
 

815 West 1800 North 

 

Logan, Utah 84321-1784 

 

CAMPBELL SCIENTIFIC, INC. does not accept collect calls. 

 

 

 

Summary of Contents for CS210

Page 1: ...CS210 Enclosure Relative Humidity Sensor Revision 10 07 C o p y r i g h t 1 9 9 6 2 0 0 7 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...f all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequ...

Page 3: ...inks to specific sections 1 General 1 2 Specifications 1 3 Installation 1 4 Wiring 2 5 Programming 3 5 1 CRBasic Examples 3 5 2 Edlog Examples 5 6 Enclosure Humidity 7 7 Maintenance 7 Figures 1 CS210...

Page 4: ...This is a blank page...

Page 5: ...er year Response Time at 25 C 90 response 10 seconds for a 30 to 90 RH step change Operating Temperature 0 C to 50 C Storage Temperature 40 C to 80 C Probe Length 2 6 cm 1 02 in Probe Cross Section Ar...

Page 6: ...ended analog input channel TABLE 1 Datalogger Connections Description Color CR200 series CR800 CR850 CR1000 CR3000 CR5000 CR9000 X CR10 X CR500 CR510 CR23X 21X Relative Humidity White Single Ended Si...

Page 7: ...rned on Depending on the scan rate the first few measurements from the CS210 could be low The probe output scale is 0 to 1000 millivolts for the relative humidity range of 0 to 100 Table 2 provides ca...

Page 8: ...d a delay VoltSe Enc_RH 1 mV2500 1 1 0 250 0 1 0 Set the sensor to 100 if it exceeds 100 If Enc_RH 100 Then Enc_RH 100 CallTable Daily NextScan EndProg Example 2 Sample CR200 Program CR200 Series Data...

Page 9: ...ple 4 is an Edlog program written for a 21X Micrologger wiring used for the 21X program is included in Table 3 The 21X program turns on control port 1 to power the CS210 Notice that the scan rate is s...

Page 10: ...o P86 1 41 Set Port 1 High 4 Volt SE P1 1 1 Reps 2 15 5000 mV Fast Range 3 1 SE Channel 4 3 Loc Enc_RH 5 0 1 Multiplier 6 0 Offset 5 If time is P92 1 0 Minutes into a 2 1440 Minute Interval 3 10 Set O...

Page 11: ...connector be sealed with plumbers putty and that desiccant packs be placed inside the enclosure Spikes in the enclosure humidity are a result of opening the enclosure door and allowing ambient air in...

Page 12: ...CS210 Enclosure Humidity Sensor This is a blank page 8...

Page 13: ...This is a blank page...

Page 14: ...L www campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Sci...

Reviews: