CANBUS INSTRUCTION PARAMETERS
Status Description
0000
SDM-CAN involved in bus activities; error counters < than 96.
0001
SDM-CAN involved in bus activities; one or more error counters is
greater than or equal to 96.
0002
SDM-CAN is not involved in bus activities; error counters < 96.
0003
SDM-CAN is not involved in bus activities; one or more error
counters is greater than or equal to 96.
30
Read SDM-CAN operating system and version number; results are placed in two
consecutive array variables beginning with the variable specified in the
Dest
ination
parameter.
31
Send Remote Frame Request.
32
Set SDM-CAN's internal switches. The code is stored in the array specified in the
Dest parameter and is entered in the form of ABCD.
Digit Value Description
A 0
Not
Used
B
0
SDM-CAN returns the last value captured from the network,
even if that value has been read before (default).
1
SDM-CAN returns -99999 if a data value is requested by the
datalogger and a new value has not been captured from the
network since the last request.
C
0
Disable I/O interrupts (default).
1
Enable I/O interrupts, pulsed mode.
2
Enable I/O interrupts, fast mode.
3-7
Currently not used.
8
Place the SDM-CAN into low power stand-by mode.
9
Leave switch setting unchanged.
D
0
Listen only (error passive) mode. CAN transmissions are not
confirmed.
1
Transmit once. Data will not be retransmitted in case of error or
loss of arbitration. Frames received without error are
acknowledged.
2
Self-reception. A frame transmitted from the SDM-CAN that
was acknowledged by an external node will also be received by
the SDM-CAN but no retransmission will occur in the event of
loss of arbitration or error. Frames received correctly from an
external node are acknowledged.
3
Normal, retransmission will occur in the event of loss of
arbitration or error. Frames received correctly from an external
node are acknowledged. This is the typical setting to use if the
SDM-CAN is to be used to transmit data.
4
Transmit once; self-test. The SDM-CAN will perform a
successful transmission even if there is no acknowledgment
from an external CAN node. Frames received correctly from an
external node are acknowledged.
5
Self-reception; self -test. The SDM-CAN will perform a
successful transmission even if there is no acknowledgment
from an external CAN node. Frames received correctly from an
external node are acknowledged. SDM-CAN will receive its
own transmission.
Summary of Contents for CR9000
Page 6: ...CR9000 Table of Contents iv This is a blank page ...
Page 22: ...CR9000 Overview OV 16 This is a blank page ...
Page 26: ...Section 1 Installation 1 4 CR9000 FIGURE 1 1 3 CR9000 Battery Pack ...
Page 72: ...Section 3 CR9000 Measurement Details 3 28 This is a blank page ...
Page 88: ...Section 5 Program Declarations 5 6 This is a blank page ...
Page 217: ...This is a blank page ...