Section 6. Data Table Declarations and Output Processing Instructions
6-4
Const RevDiff 1 'Reverse input to cancel offsets
Const Del 0
'Use default delay
Const Integ 0
'Use default Integration
Public RefTemp 'Declare the variable used for reference temperature
Public TC(5)
'Declare the variable used for thermocouple measurements
Public Flag(8)
Units RefTemp=degC
'
Units TC=degC
DataTable (AvgTemp,Flag(1),1000)'Output when Flag(1)=true
DataInterval(0,10,sec,10) 'Output every 10 seconds(while Flag(1)=true)
'OpenInterval 'When Not Commented, include data while Flag(1)=false in next average
Average(1,RefTemp,IEEE4,0)
Average(5,TC,IEEE4,0)
EndTable
BeginProg
Scan(500,mSec,0,0)
ModuleTemp(RefTemp,1,5,30)
TCDiff(TC(),5,mV50C,5,9,TypeT,RefTemp,RevDiff,Del,Integ,1,0)
CallTable AvgTemp
NextScan
EndProg
DataEvent (PreTrigRecs, StartTrig, StopTrig, PostTrigRecs)
Used to set a trigger to start storing records and another trigger to stop storing
records within a table. The number of records before the start trigger and the
number of records after the stop trigger can also be set. A filemark (Section 8) is
automatically stored in the table between each event.
Parameter
& Data Type
Enter
DataEvent Parameters
PreTrigRecs
Constant
The number of records to store before the Start Trigger.
StartTrig
The variable or expression test to Trigger copying the pre trigger records into the data table
and start storing each new record..
Variable, or
Value Result
Expression
0
Do not trigger
≠
0 Trigger
StopTrig
Variable,
Expression or
Constant
The variable, expression or constant to test to stop storing to the data table. The CR9000
does not start checking for the stop trigger until after the Start Trigger occurs. A non-zero
(true) constant may be used to store a fixed number of records when the start trigger occurs
(total number of records = PreT 1 record for the tPostTrigRecs.). Zero
(false) could be entered if it was desired to continuously store data once the start trigger
occurred.
Value Result
0
Do not trigger
≠
0 Trigger
PostTrigRecs
Constant
The number of records to store after the Stop Trigger occurs.
Summary of Contents for CR9000
Page 6: ...CR9000 Table of Contents iv This is a blank page ...
Page 22: ...CR9000 Overview OV 16 This is a blank page ...
Page 26: ...Section 1 Installation 1 4 CR9000 FIGURE 1 1 3 CR9000 Battery Pack ...
Page 72: ...Section 3 CR9000 Measurement Details 3 28 This is a blank page ...
Page 88: ...Section 5 Program Declarations 5 6 This is a blank page ...
Page 217: ...This is a blank page ...