![Campbell CR6 Series Product Manual Download Page 186](http://html1.mh-extra.com/html/campbell/cr6-series/cr6-series_product-manual_3769841186.webp)
10.2.21 MaxProcTime
Maximum time (μs) required to run through processing for the current scan. Value is reset when
the scan exits. Enter 0 to reset. Updated at the conclusion of scan processing, prior to waiting for
the next scan.
10.2.22 MaxSystemProcTime
Maximum time (μs) required to process the auto (background) calibration, which runs in a
hidden slow-sequence type scan. Displays 0 until a background calibration runs. Enter 0 to reset.
l
Numeric data type
10.2.23 MeasureOps
Reports the number of task-sequencer opcodes required to do all measurements. Calculated at
compile time. Includes operation codes for calibration (compile time), auto (background)
calibration (system), and Slow Sequences. Assumes all measurement instructions run each scan.
Updated after compile and before running.
10.2.24 MeasureTime
Reports the time (μs) needed to make measurements in the current scan. Calculated at compile
time. Includes integration and settling time. In pipeline mode, processing occurs concurrent with
this time so the sum of MeasureTime and ProcessTime is not equal to the required scan time.
Assumes all measurement instructions will run each scan. Updated when a main scan begins.
10.2.25 MemoryFree
Unallocated final-data memory on the CPU (bytes). All free memory may not be available for
data tables. As memory is allocated and freed, holes of unallocated memory, which are unusable
for final-data memory, may be created. Updated after compile completes.
10.2.26 MemorySize
Total final-data memory size (bytes) in the CR6. Updated at startup.
10.2.27 Messages
Contains a string of manually entered messages.
l
String data type
10. Information tables and settings (advanced)
168