![background image](http://html1.mh-extra.com/html/campbell/cm106be/cm106be_user-manual_489018023.webp)
User Manual
13
6.1.5
Tripod Grounding
Place the clamp over the ground rod and drive the rod (close to the centre of the
tripod) using a sledge hammer or fence post driver. Strip 12.5 mm of insulation
from both ends of the green/yellow 16 mm
2
ground wire. Insert one end of the
ground wire into the clamp and ground rod and tighten the bolt on the clamp.
Attach the other end of the ground wire to the lug on the tripod base as shown in
Figure 6-8. Trim length to suit.
Figure 6-8. Ground rod and clamp
Ground Lug
Ground Wire
Enclosure Ground Lug
Enclosure Ground Wire