background image

5

RP3300

www.chpower.com

Operation

 

For use  with 12-volt DC power outlets rated 15 amps or higher. Do not 

  use with older 8 amp cigarette lighter receptacles.

FoR low PRessuRe InFlAtIon - MAnuAl shutoFF only - 
InFlAtIon oF IteMs thAt RequIRe less thAn 20 PsI

1 .    Plug the power cord into a power outlet . 

NOTE: 

Some vehicles require the engine to 

be running to power the inflator .

2a . If inflating a low pressure 

tire

 (such as an ATV tire or lawn tractor tire), attach 

universal adapter to valve stem with the locking lever in the open/up position . Press 
the universal adapter completely onto the valve stem thread .  Failure to do so could 
lead to loss of tire pressure during this process . 

  b . If inflating a 

sports ball

, insert a metal inflation needle into the universal adapter .  

Make sure the needle is secure in the adapter .

3 .    When the universal adapter is firmly in place, press the locking lever down . (See 

Figure 2) .

4 .    Turn pressure selector dial until the desired pressure field reads “LO” (LO setting is 

just below 20 psi setting) . (See Figure 3) .

5 .    Press power button . (See Figure 4) .
6 .    When item reaches desired firmness, press power button again to stop inflation .  

The actual pressure will then read on the digital gauge after the inflator has 
stopped . (See Figure 3) .

 

If inflator immediately stops inflating and shuts off, make sure the 

  universal adapter is pressed fully on to the tire valve stem or the metal 

inflation needle is inserted correctly (See Figure 2).

7 .    If more inflation is needed, repeat steps 5 and 6 .
8 .   When desired pressure is reached, raise universal adapter lever and remove from 

the tire valve stem or remove the metal inflation needle .

 

Overinflation can be dangerous.  Pay attention while inflating low 

  pressure items to prevent overinflation.

 

Do not  allow inflator to run unattended while in “LO” setting.

FoR stAnDARD tIRe InFlAtIon - AutoMAtIC shutoFF -  
InFlAtIon oF tIRes Between 20 PsI AnD 99 PsI

1 .   Attach universal adapter to valve stem with the locking lever in the open/up 

position . Press the universal adapter completely onto the valve stem thread .  Failure 
to do so could lead to loss of tire pressure during this process .

2 .   When the universal adapter is firmly in place, press the locking lever down . (See 

Figure 2) .

3 .   Plug the power cord into a power outlet .
4 .   Turn the pressure selector dial until desired pressure is reached . (See Figure 3) .
5 .   Press power button . (See Figure 4) . Unit will turn off automatically when set 

pressure is reached .

 

If inflator immediately stops inflating and shuts off, make sure the 

  universal adapter is pressed fully on to the tire valve stem (See Figure 2 ).

6 .   When desired pressure is reached, raise universal adapter lever and remove from 

the tire valve stem or remove the metal inflation needle .

Figure 2 - lock universal Adapter securely

Figure 3 - Digital Pressure gauge  and 
Pressure selector Dial

Figure 4 - Power Button

Current 

Pressure

Desired 

Pressure

Pressure 

Selector 

Dial

Valve 

Stem

Unlocked

Locked

Universal 

Adapter

Metal 

Inflation 

Needle

Summary of Contents for IN728500AV

Page 1: ...gital Tire Inflation System Syst me de gonflement de pneus NUM RIQUE de 12 volts Sistema DIGITAL de inflado de neum ticos de 12 voltios MAKES IT EASY TO DO IT LIKE A PRO chpower com Operating Instruct...

Page 2: ...re Inflation Inflation Of Items That Require Less Than 20 psi 5 For Standard Tire Inflation Inflation Of Tires Between 20 psi and 99 psi 5 Maintenance 6 Technical Service 6 Troubleshooting Chart 6 Lim...

Page 3: ...sure 99 psi Weight 4 0 lbs Voltage 12 Volt DC Amp Draw 9 amp 0 psi 14 amp 99 psi Cord Length 10 feet Fuse 15 amp 5 mm x 20 mm 250V Automatic Shutoff Range 20 psi to 99 psi LO Setting for Manual Operat...

Page 4: ...before using the inflator or property damage and or personal injury could occur Always use a separate pressure gauge to check the actual pressure in tires and in low pressure inflatable objects Infla...

Page 5: ...metal inflation needle is inserted correctly See Figure 2 7 If more inflation is needed repeat steps 5 and 6 8 When desired pressure is reached raise universal adapter lever and remove from the tire...

Page 6: ...e s fuse for power outlet is blown 2 Replace fuse 3 Inflator s fuse for power plug is blown 3 Replace fuse see above Inflator will not start 1 Red power button not pressed 1 Press red power button 2 P...

Page 7: ...you C Any failure that results from an accident purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual s supplied with product Accident...

Page 8: ...tantes Instructions De S curit F10 Instructions Portant Sur Un Risque d Incendie Un Choc lectrique Ou Des Blessures Aux Personnes F10 Proposition 65 de Californie F10 General Safety F10 Fonctionnement...

Page 9: ...ension 12 volts c c Tirage d amp res 9 A 0 kPa 14 A 683 kPa Longueur du cordon 3 05 m Fusible 15 A 5 mm x 20 mm 250V Arr t automatique Plage 138 682 kPa 20 99 lb po R glage LO bas pour une op ration m...

Page 10: ...mettre le frein de secours et caler les roues avant d utiliser le gonfleur Sinon il y a risque de dommage mat riel et ou blessure Toujours utiliser un autre manom tre pour v rifier la pression actuel...

Page 11: ...de soupape du pneu ou que l aiguille de gonflage de m tal est ins r e correctement voir la figure 2 7 S il faut gonfler plus r p ter les tapes 5 et 6 8 En atteignant la pression voulue relevez le lev...

Page 12: ...rtie de courant est grill 2 Remplacez le fusible 3 Le fusible du gonfleur pour la fiche d alimentation est grill 3 Remplacez le fusible voir plus haut Le gonfleur ne d marre pas 1 Le bouton de courant...

Page 13: ...u exclusion pr c dente peut donc ne pas s appliquer C Toute panne r sultant d un accident d une utilisation abusive de la n gligence ou d une utilisation ne respectant pas les instructions donn es dan...

Page 14: ...portantes Instrucciones De Seguridad S16 Instrucciones En Referencia Al Peligro De Incendios Choque El ctrico O Lesiones Personales S16 Proposici n 65 de California S16 Seguridad General S16 Funcionam...

Page 15: ...A 6 83 bar Long del Cable 3 05 m Fusible 15 A 5 mm x 20 mm 250V Apagado autom tico Rango 1 39 bar 20 psi a 6 8 bar 99 psi Configuraci n LO baja para funcionamiento manual 0 a 1 31 bar 19 psi Instrucci...

Page 16: ...io de m o e trave a dire o antes de usar o inflador ou podem ocorrer danos propriedade ou ferimentos pessoais Siempre use un man metro aparte para revisar la presi n de las llantas y objetos inflamabl...

Page 17: ...neum tico o que el pincho para inflar de metal est introducido correctamente ver Figura 2 7 Si es necesario inflar m s repita los pasos 5 y 6 8 Cuando se alcance la presi n deseada eleve la palanca de...

Page 18: ...emado 2 Cambie el fusible 3 El fusible del inflador para el enchufe de corriente est quemado 3 Cambie el fusible ver arriba El inflador no enciende 1 El bot n de corriente rojo no est presionado 1 Pre...

Page 19: ...lquier falla que resulte de un accidente abuso negligencia o incumplimiento de las instrucciones de funcionamiento y uso indicadas en el los manual es que se adjunta n al producto Dichos accidentes ab...

Page 20: ...Operating Instructions u Instructions d Utilisation u Manual de Instrucciones www chpower com 20 Notes Notes Notas RP3300...

Reviews: