background image

23 Sp

FP2040

2

Oilless Compressors

General Safety
Information 

(Continued)

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the compressor.

4. Keep visitors away and NEVER allow

children in the work area.

5. Wear safety glasses

and use hearing
protection when
operating the pump
or unit.

6. Do not stand on or use the pump or

unit as a handhold.

7. Before each use, inspect compressed

air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.

8. Check all fasteners at frequent

intervals for proper tightness.

Motors, electrical
equipment and controls
can cause electrical arcs
that will ignite a flammable gas or
vapor. Never operate or repair in or
near a flammable gas or vapor. Never
store flammable liquids or gases in the
vicinity of the compressor.

Compressor parts may
be hot even if the unit
is stopped.

9. Keep fingers away from a running

compressor; fast moving and hot
parts will cause injury and/or burns.

10. If the equipment should start to

abnormally vibrate, STOP the
engine/motor and check
immediately for the cause. Vibration
is generally a warning of trouble.

11. To reduce fire hazard, keep

engine/motor exterior free of oil,
solvent, or excessive grease.

Never remove or 
attempt to adjust

safety valve. Keep safety valve free
from paint and other accumulations.

!

WARNING

!

CAUTION

!

WARNING

Never attempt to repair
or modify a tank!
Welding, drilling or any
other modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn or
damaged tanks.

Drain liquid from 
tank daily.

13. Tanks rust from moisture build-up,

which weakens the tank. Make sure
to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and
corrosion.

14. Fast moving air will stir up dust and

debris which may be harmful. Release
air slowly when draining moisture or
depressurizing the compressor system.

SPRAYING PRECAUTIONS

Do not spray flammable
materials in vicinity of
open flame or near
ignition sources including the
compressor unit.

15. Do not smoke when spraying paint,

insecticides, or other flammable
substances.

16. Use a face mask/

respirator when
spraying and spray in
a well ventilated area
to prevent health and
fire hazards.

17. Do not direct paint or other sprayed

material at the compressor. Locate
compressor as far away from the
spraying area as possible to
minimize overspray accumulation
on the compressor.

18. When spraying or cleaning with

solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.

!

WARNING

!

WARNING

!

DANGER

Installation

LOCATION

It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than 100°F.

A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.

Do not locate the 
compressor air

inlet near steam, paint spray, sandblast
areas or any other source of
contamination. This debris will damage
the motor.

Never use an extension
cord with this product. Use
additional air hose instead
of an extension cord to
avoid power loss and permanent motor
damage. Use of an extension cord voids
the warranty.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 1. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.

!

CAUTION

!

CAUTION

STOP!

TEST

RESET

Figure 1 - Grounding Method

Grounding

Pin

Grounded Outlet

No. de

Numero

No. de

Numero

Ref.

Descripción

de pieza

Ctd.

Ref.

Descripción

de pieza

Ctd.

Liste de Repuestos

Sírvase darnos la siguiente información:

Puede escribirnos a:

-Número del modelo

The Campbell Group / Attn: Parts Department

-Número de Serie (de haberlo) 

100 Production Drive

-Descripción y número del repuesto según la lista de repuestos

Harrison, OH  45030 U.S.A.

Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio

1

Cubierta con mango

FP204001AV

1

2

Ensamblaje del mango

FP204002AV

1

3

Manómetro del tanque

FP200347AV

1

4

Regulador

FP200345AV

1

5

Múltiple

FP204003AV

1

6

Válvula de seguridad

V-215102AV

1

7

Interruptor

FP200343AV

1

8

Llave de drenaje

D-1401

1

9

Ensamblaje de la 
bomba/motor

FP204004AV

1

10

Tablero de circuitos

FP204005AV

1

11

Presostato

FP200354AV

1

12

Tubo de salida 

1

13

Ventilador

FP204006AV

1

14

Tuerca de compresión

FP200353AV

2

15

Casquillo de compresión

2

16

Tornillos de la tapa - 

Artículo estándar 

M6-1.0 x 20

de ferretería

4

17

Manguera de 7,6 m (25 pies)

MP285100AV

1

18

Juego de herramientas (5 piezas)FP204008AV

1

19

Juego válvula de chequeo 

FP204010AV

1

20

Storage cover

FP204007AV

1

21

Ensamblaje del émbolo

FP204009AV

1

Juego del tubo de salida
(incluye Nº 12, 14 & 15)

FP200339AV

1

Juego de etiqueta adhesiva 
(no se muestra)

FP204011AV

1

100

100

ps

i

ps

i

10

10

15

0

15

0

10

10

15

0

15

0

125

125

75

75

66

88

75

75

100

100

125

125

44

66

88

44

22

5050

ba

r

ba

r

50 50

22

00

25 25

25 25

ps

i

ps

i

00

0 0

ba

r

ba

r

0 0

20

16

1

3

6

7

5

8

11

10

9

21

14

15

12

19

14

15

13

4

2

17

18

www.chpower.com

Summary of Contents for FP2040

Page 1: ...dicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed MAY cause damage to equipment Unpackin...

Page 2: ...ressurizing the compressor system SPRAYING PRECAUTIONS Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit 15 Do not smoke when spraying p...

Page 3: ...ls the amount of air pressure released at the hose outlet ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Handle Designed to move the compressor...

Page 4: ...rom tank by opening drain cock underneath tank Tilt tank to remove all moisture 3 Clean dust and dirt from motor tank air lines and pump cooling fins while compressor is still OFF LUBRICATION This is...

Page 5: ...ir from tank and refer to actions 1 and 2 4 Release air from tank 5 Reset determine cause of problem 6 Replace pressure switch 1 Check for proper fuse in supply circuit Disconnect other electrical app...

Page 6: ...ith higher air delivery SCFM 2 Replace leaking components or tighten as necessary 3 Replace pump assembly 4 Replace piston assembly 1 Drain tank tilt tank to remove moisture 2 Move to area of less hum...

Page 7: ...12 Exhaust tube 1 13 Fan FP204006AV 1 14 Compression nut 2 15 Compression ferrule 2 16 Shroud screws M6 10 x 20 Standard hardware item 4 17 25 hose MP285100AV 1 18 Tool kit 5 pieces FP204008AV 1 19 C...

Page 8: ...sly excluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered un...

Page 9: ...se potentielle qui PEUT r sulter en perte de vie ou blessures graves Attention indique une situation hasardeuse potentielle qui PEUT r sulter en blessures Avis indique de l information importante pour...

Page 10: ...en purgeant l humidit ou pendant la d pressurisation du syst me du compresseur PR CAUTIONS DE PULV RISATION Ne pas pulv riser les mat riaux inflammables dans un endroit de flamme ouverte ni pr s d une...

Page 11: ...Fonctionnement R gulateur Le r gulateur sert r gler la pression d air la sortie du tuyau Soupape de S ret ASME Cette soupape laisse chapper l air si la pression du r servoir d passe la pression maximu...

Page 12: ...sa position normale S il y a une fuite apr s que la soupape soit l ch e ou si la soupape ne fonctionne pas elle devrait tre remplac e 2 Avec le compresseur hors circuit et la pression dissip e purger...

Page 13: ...fin que l interrupteur de surcharge se rajuste Si le mod le ne se d marre pas vider le r servoir d air et se r f rer aux mesures 1 et 2 4 Faire dissiper de l air du r servoir 5 Rajuster rechercher la...

Page 14: ...1 Diminuer l usage ou acheter un mod le avec un d bit d air m3 min plus lev 2 Remplacer les pi ces d tach es qui ont des fuites ou serrer au besoin 3 Remplacer le montage de la pompe 4 Remplacer le mo...

Page 15: ...ff FP200343AV 1 8 Robinet de vidange D 1401 1 9 Montage de pompe moteur FP204004AV 1 10 Carte de circuits imprim s FP204005AV 1 11 Manostat FP200354AV 1 12 Tuyau d chappement 1 13 Ventilateur FP204006...

Page 16: ...la garantie du fabricant de moteur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es...

Page 17: ...ndica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad Esto le indica que hay una situaci n que PODRIA ocasionarle heridas no muy graves sto le indica una informaci n impor...

Page 18: ...e inspeccionar peri dicamente para detectar condiciones de peligro como la formaci n de xido y corrosi n 14 La circulaci n r pida de aire podr a levantar polvo y desperdicios da inos Siempre libere el...

Page 19: ...Regulador El regulador controla la cantidad de presi n de aire expulsada por la manguera V lvula de seguridad ASME Esta v lvula autom ticamente libera el aire si la presi n del tanque excede el valor...

Page 20: ...presi n del sistema antes de tratar de instalar darle servicio cambiar de lugar o darle cualquier tipo de mantenimiento Este compresor se debe chequear con frecuencia para ver si tiene alg n tipo de p...

Page 21: ...o que el dispositivo de sobrecarga t rmica se reactive Si la unidad a n no se enciende vac e el aire del tanque y regrese a los pasos 1 y 2 4 Libere el aire del tanque 5 Cierre el cortacircuito y dete...

Page 22: ...lvula de retenci n con aire en el tanque purgue el tanque 1 Disminuya el uso o compre una unidad con mayor impulsi n de aire m3 min 2 Cambie los componentes con fuga o ajuste como sea necesario 3 Ree...

Page 23: ...r FP200343AV 1 8 Llave de drenaje D 1401 1 9 Ensamblaje de la bomba motor FP204004AV 1 10 Tablero de circuitos FP204005AV 1 11 Presostato FP200354AV 1 12 Tubo de salida 1 13 Ventilador FP204006AV 1 14...

Page 24: ...r debe seguir las clausulas de la garant a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compre...