7. Attach chuck or other tool to open

end of hose. Turn the regulator on.

In the ON position, the compressor
pumps air into the tank. It shuts off
automatically when unit reaches its
maximum preset pressure. In the OFF
position, the pressure switch cannot
function and the compressor will not
operate. Make sure switch is in OFF
position when connecting or
disconnecting power cord from
electrical outlet.

ASME SAFETY VALVE

Do not remove or 
attempt to adjust

the safety valve!

This valve should be checked
occasionally by pulling the ring by
hand. Air may leak even after ring has
been released. However, if the leaking
continues for an extended period of
time, or if the safety valve is stuck and
cannot be activated by the ring, the
safety valve MUST be replaced. (Note:
Valve will reset when tank pressure
reaches 40-50 PSI.)

REGULATOR KNOB

1. This knob controls air pressure to an

air operated tool or paint spray gun.

2. Turn knob clockwise to increase air

pressure.

3. To lower air pressure turn knob

counterclockwise.

4. Turn fully counterclockwise to shut

off flow of air completely.

Maintenance

Disconnect power
source then release all
pressure from the
system before
attempting to install,
service, relocate or perform any
maintenance.

!

WARNING

!

WARNING

Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.

1. Pull ring on safety valve and allow it

to snap back to normal position.

Safety valve must 
be replaced if it

cannot be actuated or it leaks air after
ring is released.

2. Turn compressor off and release

pressure from system. Drain moisture
from tank by opening drain cock
underneath tank. Tilt tank to remove
all moisture.

3. Clean dust and dirt from motor, tank,

air lines and pump cooling fins while
compressor is still OFF.

LUBRICATION

This is an oilless type compressor
requiring no lubrication.

THERMAL OVERLOAD PROTECTOR

This compressor is 
equipped with an

automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.

If thermal overload protector shuts
motor OFF frequently, look for the
following causes.

1. Low voltage.

2. Clogged air filter.

3. Lack of proper ventilation.

!

CAUTION

!

WARNING

If the thermal 
overload protector

is actuated, the motor must be allowed
to cool down before start-up is possible.
The motor will automatically restart
without warning if left plugged into
electrical outlet and unit is turned on.

STORAGE

1. When not in use, store hose and

compressor in a cool dry place.

2. Drain tank of moisture.

3. Disconnect hose and hang open ends

down to allow any moisture to drain.

!

CAUTION

Figure 3

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the tank. When
using a paint spray or sandblast gun, this water will be carried from the tank
through the hose, and out of the gun as droplets mixed with the spray material.

IMPORTANT: 

This condensation will cause water spots in a paint job, especially

when spraying other than water based paints. If sandblasting, it will cause the
sand to cake and clog the gun, rendering it ineffective. A filter in the air line
(MP3105), located as near to the gun as possible, will help eliminate this
moisture.

Oilless Compressors

Figure 4

FP2040

Guía de diagnóstico de averías

Problema

Posible(s) Causa(s)

Acción a tomar

1. No hay corriente eléctrica, o el

interruptor está en 

OFF

(apagado)

2. El fusible está quemado 

3. El motor está sobrecargado

4. La presión del tanque está al máximo
5. El cortacircuito (cuchilla) está abierto

6. El presostato está dañado

1. Tamaño incorrecto de fusible,

circuito sobrecargado

2. Válvula de retención defectuosas

1. Bajo voltaje

2. Falta de ventilación adecuada o

temperatura ambiente muy alta

3. Compruebe si la válvula no funciona

bien

4. Fallaron las válvulas del compresor

1. Pernos flojos, tanque no nivelado
2. Cojinete defectuoso en la excéntrica

o en el eje del motor

3. Cilindro o anillo de émbolo gastados

o rayados

1. Cerciórese de que el compresor esté conectado al

tomacorriente y el interruptor esté en ON
(encendido)

2. Desconecte el compresor del tomacorriente y

destape el cabezal. Reemplace el fusible (pieza No.
FP200352AV)

3. Permita que el compresor se enfríe por

aproximadamente 30 minutos de modo que el
dispositivo de sobrecarga térmica se reactive. Si la
unidad aún no se enciende, vacíe el aire del tanque
y regrese a los pasos 1 y 2

4. Libere el aire del tanque
5. Cierre el cortacircuito y determine la causa del

problema

6. Reemplace el preóstato

1. Verifique que el fusible sea el adecuado en el circuito

de alimentación. Desconecte otros artefactos 
eléctricos del circuito o haga funcionar el compresor
con su propio circuito derivado

2. Reemplace el ensamblaje de la válvula de chequeo

No desarme la válvula 

de retención con aire

en el tanque; purgue el tanque

1. Elimine el cordón de extensión, revise con un

voltímetro

2. Mueva el compresor a una zona bien ventilada

3. Reemplace el ensamblaje de la válvula de chequeo

4. Reemplace cabezal

No desarme la válvula 

de retención con aire

en el tanque; purgue el tanque

1. Ajuste los pernos, calce el tanque para nivelarlo
2. Reemplace cabezal

3. Reemplace cabezal

!

PRECAUCION

!

PRECAUCION

El compresor no
funciona

Los fusibles vuelan o el
interruptor de circuito
se desconecta
repetidamente

Nunca use un cordón
de extensión con
este producto

El protector de
sobrecarga térmica se
activa repetidamente

Golpeteos, cascabeleos,
vibración excesiva

!

PRECAUCION

www.chpower.com

Summary of Contents for FP2040

Page 1: ...dicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed MAY cause damage to equipment Unpackin...

Page 2: ...ressurizing the compressor system SPRAYING PRECAUTIONS Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit 15 Do not smoke when spraying p...

Page 3: ...ls the amount of air pressure released at the hose outlet ASME Safety Valve This valve automatically releases air if the tank pressure exceeds the preset maximum Handle Designed to move the compressor...

Page 4: ...rom tank by opening drain cock underneath tank Tilt tank to remove all moisture 3 Clean dust and dirt from motor tank air lines and pump cooling fins while compressor is still OFF LUBRICATION This is...

Page 5: ...ir from tank and refer to actions 1 and 2 4 Release air from tank 5 Reset determine cause of problem 6 Replace pressure switch 1 Check for proper fuse in supply circuit Disconnect other electrical app...

Page 6: ...ith higher air delivery SCFM 2 Replace leaking components or tighten as necessary 3 Replace pump assembly 4 Replace piston assembly 1 Drain tank tilt tank to remove moisture 2 Move to area of less hum...

Page 7: ...12 Exhaust tube 1 13 Fan FP204006AV 1 14 Compression nut 2 15 Compression ferrule 2 16 Shroud screws M6 10 x 20 Standard hardware item 4 17 25 hose MP285100AV 1 18 Tool kit 5 pieces FP204008AV 1 19 C...

Page 8: ...sly excluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered un...

Page 9: ...se potentielle qui PEUT r sulter en perte de vie ou blessures graves Attention indique une situation hasardeuse potentielle qui PEUT r sulter en blessures Avis indique de l information importante pour...

Page 10: ...en purgeant l humidit ou pendant la d pressurisation du syst me du compresseur PR CAUTIONS DE PULV RISATION Ne pas pulv riser les mat riaux inflammables dans un endroit de flamme ouverte ni pr s d une...

Page 11: ...Fonctionnement R gulateur Le r gulateur sert r gler la pression d air la sortie du tuyau Soupape de S ret ASME Cette soupape laisse chapper l air si la pression du r servoir d passe la pression maximu...

Page 12: ...sa position normale S il y a une fuite apr s que la soupape soit l ch e ou si la soupape ne fonctionne pas elle devrait tre remplac e 2 Avec le compresseur hors circuit et la pression dissip e purger...

Page 13: ...fin que l interrupteur de surcharge se rajuste Si le mod le ne se d marre pas vider le r servoir d air et se r f rer aux mesures 1 et 2 4 Faire dissiper de l air du r servoir 5 Rajuster rechercher la...

Page 14: ...1 Diminuer l usage ou acheter un mod le avec un d bit d air m3 min plus lev 2 Remplacer les pi ces d tach es qui ont des fuites ou serrer au besoin 3 Remplacer le montage de la pompe 4 Remplacer le mo...

Page 15: ...ff FP200343AV 1 8 Robinet de vidange D 1401 1 9 Montage de pompe moteur FP204004AV 1 10 Carte de circuits imprim s FP204005AV 1 11 Manostat FP200354AV 1 12 Tuyau d chappement 1 13 Ventilateur FP204006...

Page 16: ...la garantie du fabricant de moteur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es...

Page 17: ...ndica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad Esto le indica que hay una situaci n que PODRIA ocasionarle heridas no muy graves sto le indica una informaci n impor...

Page 18: ...e inspeccionar peri dicamente para detectar condiciones de peligro como la formaci n de xido y corrosi n 14 La circulaci n r pida de aire podr a levantar polvo y desperdicios da inos Siempre libere el...

Page 19: ...Regulador El regulador controla la cantidad de presi n de aire expulsada por la manguera V lvula de seguridad ASME Esta v lvula autom ticamente libera el aire si la presi n del tanque excede el valor...

Page 20: ...presi n del sistema antes de tratar de instalar darle servicio cambiar de lugar o darle cualquier tipo de mantenimiento Este compresor se debe chequear con frecuencia para ver si tiene alg n tipo de p...

Page 21: ...o que el dispositivo de sobrecarga t rmica se reactive Si la unidad a n no se enciende vac e el aire del tanque y regrese a los pasos 1 y 2 4 Libere el aire del tanque 5 Cierre el cortacircuito y dete...